I/O Unit Cover
DC Two-wire Sensor
Connection Precautions
Wiring Examples
I/O Connections
V
V
I
I
R
ON
OFF
CC
ON
IN
:
:
Two-wire sensor
:
:
:
Power supply voltage
PC ON voltage
PC OFF current
PC OFF current
PC input impedance
A C200H-COV11 Cover is provided as an I/O Unit cover for Units that use 10P
terminal block connectors. After the I/O wiring has been completed, slide the
cover up from the bottom, as shown in the illustration below.
If a two-wire sensor is used with a 12-VDC or 24-VDC input device, make sure
that the following conditions are satisfied. Malfunctions will occur if these condi-
tions are not satisfied.
• The relationship between the PC ON voltage and the sensor residual voltage is
• The relationship between the PC ON current and the sensor control output
• The relationship between the PC OFF current and sensor leakage current is as
The value of I
cified OFF current, however, the value of I
The following are examples of how to connect I/O devices to I/O Units. During
wiring, work slowly and carefully. If an input device is connected to an Output
Unit, damage may result. Check all I/O devices to make sure they meet the spec-
ifications (refer to Appendix B Specifications ).
as follows:
(load current) is as follows:
follows:
V
I
I
Connect R bleeder resistance if I
The constant for bleeder resistance is determined by the following equation.
R x (V
Power W y (V
I
Refer to the information on input and output leakage current on page 56 for
details.
OUT (min)
ON
OFF
ON
= (V
x V
x I
CC
V
CC
leak
OFF
R
CC
x I
– V
– V
– V
ON
depends on the Unit used. For Input Units that have an unspe-
R
V
R
)/(I
CC
V
I
I
R:
R
OUT
leak
x I
– 1.5 (PC internal residual voltage))/R
CC
R
Remove
Attach
OUT (min)
:
:
:
– V
OUT (max)
R
R
Sensor output residual voltage
Sensor control output (load current)
Sensor leakage current
Bleeder resistance
)
2
/R 4 (margin)
– I
ON
)
ON
R
is less than I
IN
OFF
DC Input Unit
I/O Unit cover
is always 1.8 mA.
OUT (min)
IN
Section
.
4-4
41
Related parts for C200H-OA223
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
C200H I/O CABLE, .7M
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
C200H I/O CABLE, 2M (COO)
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
C200H I/O CABLE, 5M
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
I/O Module
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
I/O UNIT SPACER
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
I/O TERMINAL COVER 10P
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
I/O TERMINAL COVER 19P
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
C200H 5&8-PT. TERM.COVER
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
C200H DIN RAIL ADAPTER
Manufacturer:
Omron
Datasheet: