C200H-COV02 Omron, C200H-COV02 Datasheet
C200H-COV02
Specifications of C200H-COV02
Related parts for C200H-COV02
C200H-COV02 Summary of contents
Page 1
... A, 5 VDC 24 VDC, Output capacity: 4 VDC I/O Control Unit For Expansion Racks connected over a distance of more than terminating resistors included. C200H Modules cannot be used on Long-distance Expansion Racks.) Note: When using a CS1W-CN313 or CS1W-CN713 I/O Connecting Cable with a CS1j-CPUjjH CPU, use only Cables produced on or after September 20, 2001 (production number 2091) ...
Page 2
... Programming Connects the CQM1-PRO01-E Programming Console. (Length: 0.05 m) Console Connecting Console Connecting Cables Connects the C200H-PRO27-E Programming Console. (Length: 2.0 m) Connects the C200H-PRO27-E Programming Console. (Length: 6.0 m) CX-Programmer For 1 license For 3 licenses For 10 licenses Peripheral Device Connects DOS computers, D-Sub 9-pin receptacle (Length: 0.1 m) ...
Page 3
... VDC 100 to 120 VAC or 200 to 240 VAC (with RUN output) Output capacity VDC I/O Interface Unit For Expansion Racks connected over a distance of more than 12 m. (C200H Modules cannot be used on Long-distance Expansion Racks.) CS1 I/O Connecting Cables / g Connects CS1 Expansion I/O Backplanes (See note ...
Page 4
... Connecting Cables CPU Backplanes or CS1 Expansion I/O CPU B Backplanes. Backplanes C200H I/O Connecting / g Connects C200H Expansion I/O Backplanes C bl Cables to other C200H Expansion I/O Backplanes. h C200H E J C200H Basic I/O Modules Mountable Racks Name Specifications p CPU Rack DC Input VDC, Yes Modules ...
Page 5
... Yes put Mod- ules 32 outputs Yes Note: 1. Interrupt Input Modules can only be used to input interrupts on the CPU Rack. They will function as normal I/O Modules on other Racks. 2. C200H-B7A12/02/21/22are C200H Group-2 Modules. C--174 Programmable Controller C200H CS1 CS1 SYSMAC Expansion Expansion Long ...
Page 6
... Interrupt Input Modules can only be used to input interrupts on the CPU Rack. They will function as normal I/O Modules on other Racks. 2. C200H-B7A12/02/21/22are C200H Group-2 Modules. 3. The C200H-ID001 (no-voltage contacts, 8 inputs, NPN) and C200H-ID002 (no-voltage contacts, 8 inputs, PNP) cannot be used. J C200H Group-2 High-density I/O Modules ...
Page 7
... Note: 1. Refer to the XW2j Connector-T erminal Block Conversion Unit catalog for details. (Square boxes indicate the cable length.) 2. The XW2Z-jjjD, CS1W-ODjjj, and C200H-ODjjj cannot be connected. Only the inputs of the CS1W-MDjjj can be connected. J CS1 High-density I/O Modules Mountable Racks Name ...
Page 8
... A, 48 inputs VDC, 0 outputs, sinking inputs/outputs 24 VDC, approx. Yes inputs VDC, 0 outputs, sourcing inputs/outputs Note: Interrupt input is not available when mounted on these Racks (i.e., used as normal I/O Unit). C200H CS1 CS1 SYSMAC Expansion Expansion Long- BUS I/O Racks Racks distance Slave Racks ...
Page 9
... Pressure welded Terminal block 1:1 1:2 1:3 Note: Refer to the XW2j Connector-T erminal Block Conversion Unit catalog for details. (Square boxes indicate the cable length.) J C200H High-density I/O Modules Classified as Special I/O Modules Name Specifications Mountable Racks CPU Rack DC Input Modules ...
Page 10
... J Connectors for C200H High-density I/O Modules Part Connection Applicable Soldered connectors (included with Unit) Crimped Pressure welded Terminal block Special Cable connection parts p Terminal Block Connector Special Cable Terminal Block Connector Note: Refer to the XW2j Connector-T erminal Block Conversion Unit catalog for details. (Square boxes indicate the cable length ...
Page 11
... CS1 Ordering Guide Special I/O Modules J C200H Special I/O Modules Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Temperature Thermocou- Yes Yes Control Mod- ple input, ules time-propor- tioning PID, or ON/OFF transistor out- put Yes Yes Thermocou- ple input, ...
Page 12
... C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Heat/Cool Thermocou- Yes Yes Temperature ple input, Control time-propor- Modules tioning PID, or ON/OFF transistor out- put Thermocou- Yes Yes ple input, time-propor- tioning PID, or ON/OFF voltage out- ...
Page 13
... CS1 Ordering Guide Special I/O Modules C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks PID Control Voltage out- Yes Yes Modules put/current input, time- proportioning PID, or ON/ OFF transis- tor output Voltage out- Yes ...
Page 14
... C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Data Setting Used with --- Console Cam Positioner Unit. Monitoring, setting, and changing present values, set points, alarm values, PID parameters, bank numbers, etc. Connecting --- Cable Connecting ...
Page 15
... CS1 Ordering Guide Special I/O Modules C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Analog Out mA, 1 Yes Yes put Modules to 5 (selectable); 2 outputs; 1/4,075 reso- lution mA, Yes Yes --10 to +10 V (selectable), 4 outputs; voltage: ...
Page 16
... C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks High-speed One-axis Yes Yes Counter pulse input, Modules counting rate: 50 kcps max. One-axis Yes Yes pulse input, counting rate: 75 kcps max., line driver com- patible Two-axis ...
Page 17
... CS1 Ordering Guide Special I/O Modules C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Motion Con- G-language Yes Yes trol Modules program- mable, two- axis analog outputs MC Support --- Software IBM PC/AT or compat- ible Connecting --- Cable: 3 ...
Page 18
... C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Position Peripheral --- Control Mod- Port Con- ules necting Cables for computer RS-232C --- Port Con- necting ti Cables for computer computer 1-axis Relay Unit for C200HW- NC113 2-axis Relay ...
Page 19
... CS1 Ordering Guide Special I/O Modules C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks ID Sensor Electromag- Yes Yes Modules netic cou- pling Microwave Yes Yes type Fuzzy Logic Use with Yes Yes Unit Fuzzy Sup- ...
Page 20
... V, -- mA) Reso- lution: 1/4,000 8 outputs ( -- mA) Reso- lution: 1/4,000 8 outputs ( mA) Resolution: 1/4,000 Analog I/O 4 inputs ( mA Unit 5 V, etc.) 4 outputs ( etc.) C200H CS1 CS1 Long- SYSMAC Expansion Expansion distance BUS Slave I/O Racks Racks Racks Racks No Yes Yes No No Yes Yes No No Yes ...
Page 21
... Input Unit 100 mA, ±100 mV Support Setting tool --- Software software for the Proces- sing I/O Mod- ules, OS: Windows 95, 98, NT 4.0 (see note) C--190 Programmable Controller C200H CS1 CS1 Long- SYSMAC Expansion Expansion distance BUS Slave I/O Racks Racks Racks Racks No Yes Yes No (This table continues on the next page ...
Page 22
... I/O connectors) MC Terminal Block Conversion Unit for 4 Axes (simplifies wiring I/O connectors) MC Terminal Block Conversion Unit Cable Note: Setting tool software for the Processing I/O Modules also supports CS1W-ADjjj, CS1WS-DAjjj, and CS1W-MAD44. C200H CS1 CS1 Long- SYSMAC Expansion Expansion distance BUS Slave ...
Page 23
... CS1 Ordering Guide CPU Bus Modules CS1 CPU Bus Modules (Continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Controller Twisted pair Yes Link Mod- Optical ring Yes No ules (H-PCF cable) Optical ring Yes No (GI cable) Controller For PCI Bus ...
Page 24
... Available in Canada only. Words allocated CS1 CS1 SYSMAC (CIO 1500 Expansion Long- BUS to Racks distance Slave CIO 1899) Racks Racks --- --- --- --- --- --- --- Programmable Controller CS1 Ordering Guide CPU Bus Modules Unit Standards Part number N No. --- --- WS02-LCTC1-E --- --- WS02-LCTK1-EL01 CE --- CS1W-CN118 --- CS1W-CN226 --- CS1W-CN626 --- --- C200H-CN229-EU CBL-202* --- --- CS1W-C1F31 CS1 C--193 ...
Page 25
... Provides CompoBus/S Master. I/O Link Modules 512 internal inputs/512 internal outputs (between CS1 or C200HX/HG/HE PLC and Master) 16 internal inputs/16 internal outputs (between CQM1/CQM1H PLC and Master) 32 internal inputs/32 internal outputs (between CPM1A/CPM2A PLC and Master) Remote Transistor I/O Terminals / ...
Page 26
DeviceNet Slaves (continued) Slave Specifications Remote Common power p 16 input points (NPN with + common) Transistor T i supply for input points (PNP with -- common) I/O Terminals I/O Terminals communications and communications and 8 input ...
Page 27
CS1 Ordering Guide DeviceNet Slaves DeviceNet Slaves (continued) Slave Specifications Water-resistant Terminals (transistor ( 4 inputs (NPN, + common) I/O) I/O) 4 inputs (PNP, -- common) 8 inputs (NPN, + common) 8 inputs (PNP, -- common) 4 outputs (NPN, -- ...
Page 28
J Smart DeviceNet I/O Terminals Basic Modules Product Smart I/O basic Modules automatically / y collect network status and connected device performance information device performance information 3--tier Terminal Block Types yp MIL Connector Terminal Block Types ...
Page 29
CS1 Ordering Guide DeviceNet Enhanced Products IP67 Rated Transistor Terminals with M12 Connectors Product Terminals with IP67-rated water-washdown resistance DeviceNet Enhanced Products Product Vision sensors Operator interface terminal adapter for NT31/NT631 touch screens Communications module for fiber--optic ...
Page 30
DeviceNet Enhanced Products (continued) Product Specifications Servo drive, W--series Communicate positioning commands, drive parameters, position- adapter ing data, motor characteristics etc, between the W-series servo and a DeviceNet master. Commands received via DeviceNet are output to the W-series servo drive ...
Page 31
CS1 Ordering Guide DeviceNet Multiple I/O Terminal Modules J DeviceNet Multiple I/O Terminal Modules Name Communications Unit Digital I Modules with Terminal Modules Blocks Bl k Modules with MOLEX C Connectors Modules with Fujitsu j ...
Page 32
J CompoBus/S Slave Modules Name Specifications I/O Link Modules / For CPM2C; 8 input points, 8 output points For CPM1A/CPM2A; 8 input points, 8 output points Remote I/O Terminals with Transistors / 4 input points, NPN (+ common) 4 input ...
Page 33
CS1 Ordering Guide CompoBus/S Modules CompoBus/S Slave Modules (Continued) Name Specifications Remote I/O Terminals with Transistors / 32 input points, NPN (+ common) and Connectors input points, PNP (-- common) 32 output points, NPN (-- common) 32 ...
Page 34
... Spacer --- CS1 Ordering Guide Specifications For 3-slot Backplane For 5-slot Backplane For 8-slot Backplane For 10-slot Back- plane Specifications Programmable Controller Optional Products Standards Part number --- C200H-COV11 C200H-COV02 C200H-COV03 C500-COV01 CV500-COV01 C200HW-ATT32 C200HW-ATT52 C200HW-ATT82 C200HW-ATTA2 --- G6B-1174P-FD-US C200H-ATT01 --- C200H-SP001 U, C CV500-TER01 Standards ...
Page 35
...
Page 36
Cat. No. R301-E3-01 2/04 Specifications subject to change without notice Printed in USA ...