E3S-CL2 Omron, E3S-CL2 Datasheet - Page 9

50CM, ADJ SENSING DIST, NPN/PNP

E3S-CL2

Manufacturer Part Number
E3S-CL2
Description
50CM, ADJ SENSING DIST, NPN/PNP
Manufacturer
Omron
Series
E3S-CLr
Datasheets

Specifications of E3S-CL2

Rohs Compliant
YES
Sensing Distance
0.197" ~ 7.874" (5mm ~ 200mm) ADJ
Sensing Method
Reflective, Diffuse
Sensing Object
Black Paper, White Paper
Output Configuration
NPN/PNP - Dark-ON/Light-ON - Selectable
Sensing Light
Infrared
Mounting Type
Bracket Mount
Current - Supply
35mA
Voltage - Supply
10 V ~ 30 V
Package / Case
Module, Pre-Wired
Features
NPN/PNP Selectable Output
Sensing Range
50mm To 500mm
Sensor Output
Open Collector
Supply Voltage Range Dc
10V To 30V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3S-CL2
Manufacturer:
OMRON
Quantity:
475
H
H
H
Precautions
To avoid malfunction or damage, do not wire the input/output lines
within the same conduit with power lines or high voltage lines.
The cord connected to the Sensor can be extended up to 100 m pro-
vided that the diameter of each wire of the cord is 0.3 mm
If a standard switching regulator is used as a power supply, the
frame ground (FG) terminal and the ground (G) terminal must be
grounded, otherwise the Sensor may malfunction due to the switch-
ing noise of the power supply.
H
Note: 1. The E3S-CL2 maintained a minimum insulation resistance of 100 M$ after the E3S-CL2 was dipped in all the above oils at a
The E3S-CL2 uses an oil-resistant cord to ensure oil resistivity.
Do not allow the cable to be repeatedly bent during application.
Do not allow the cable to be bent to a radius of less than 25 mm.
Oil
Lubricating oil
Water insoluble machining oil
Water soluble machining oil
E3S-CL
CONNECTION
POWER SUPPLY
OIL AND CHEMICAL RESISTANCE (E3S-CL2)
CABLE
2. When using the E3S-CL2 in a place where an oil other than the ones listed above is sprayed on the E3S-CL2, refer to the
temperature of 50!C for 240 hours.
above kinematic viscosity and ph values. The location may be suitable for the E3S-CL2 if the kinematic viscosity and pH values
of the oil are close to the above kinematic viscosity and pH values, but make sure that the oil does not contain any additive that
may have a negative influence on the E3S-CL2.
g
g
Kinematic Viscosity (mm
2.02
10 min. and less than 50
Less than 10
---
2
minimum.
2
/s (cst)) at 40!C
10
H
A maximum of 100 ms is required from the time power is turned on
until the E3S-CL is able to detect objects. If power is supplied to the
loads and the E3S-CL from different sources, turn on power to the
E3S-CL first.
H
To ensure the water resistance of the E3S-CL, tighten the screws of
the operation panel cover to a torque of 2.5 to 5.0 kgf S cm (0.25 N S
m to 0.49 N S m).
H
If an inverter motor or servomotor is used with the E3S-CL, the
frame ground (FG) terminal and the ground (G) terminal must be
grounded, otherwise the Sensor may malfunction.
STARTUP OPERATION
WATER RESISTANCE
MALFUNCTIONING
pH
---
7 to 9.5
7 to 9.9
7 to 9.2
7 to 9.8
E3S-CL