xiv
Application Precautions
• Do not apply voltages to the Input Units in excess of the rated input voltage.
• Do not apply voltages or connect loads to the Output Units in excess of the
• Disconnect the functional ground terminal when performing withstand voltage
• Be sure that all the mounting screws, terminal screws, and cable connector
• Leave the label attached to the Unit when wiring. Removing the label may re-
• Remove the label after the completion of wiring to ensure proper heat dissipa-
• Double-check all wiring and switch settings before turning ON the power sup-
• Wire correctly. Incorrect wiring may result in burning.
• Mount Units only after checking terminal blocks and connectors completely.
• Be sure that the terminal blocks, Memory Units, expansion cables, and other
• Check the user program for proper execution before actually running it on the
• Confirm that no adverse effect will occur in the system before attempting any of
• Resume operation only after transferring to the new CPU Unit the contents of
• Do not pull on the cables or bend the cables beyond their natural limit. Doing
• Do not place objects on top of the cables or other wiring lines. Doing so may
• Use crimp terminals for wiring. Do not connect bare stranded wires directly to
• When replacing parts, be sure to confirm that the rating of a new part is correct.
• Before touching a Unit, be sure to first touch a grounded metallic object in order
Excess voltages may result in burning.
maximum switching capacity. Excess voltage or loads may result in burning.
tests. Not disconnecting the functional ground terminal may result in burning.
screws are tightened to the torque specified in this manual. Incorrect tighten-
ing torque may result in malfunction.
sult in malfunction if foreign matter enters the Unit.
tion. Leaving the label attached may result in malfunction.
ply. Incorrect wiring may result in burning.
items with locking devices are properly locked into place. Improper locking
may result in malfunction.
Unit. Not checking the program may result in an unexpected operation.
the following. Not doing so may result in an unexpected operation.
the DM Area, HR Area, and other data required for resuming operation. Not
doing so may result in an unexpected operation.
either of these may break the cables.
break the cables.
terminals. Connection of bare stranded wires may result in burning.
Not doing so may result in malfunction or burning.
to discharge any static built-up. Not doing so may result in malfunction or dam-
age.
• Changing the operating mode of the PC.
• Force-setting/force-resetting any bit in memory.
• Changing the present value of any word or any set value in memory.