7MBR100SB-060-50 FUJI ELECTRIC, 7MBR100SB-060-50 Datasheet - Page 9

no-image

7MBR100SB-060-50

Manufacturer Part Number
7MBR100SB-060-50
Description
PIM 7PK IGBT MOD +I/P BR 100A 600V PT
Manufacturer
FUJI ELECTRIC
Datasheet

Specifications of 7MBR100SB-060-50

Module Configuration
Seven
Transistor Polarity
N Channel
Dc Collector Current
100A
Collector Emitter Voltage Vces
2.6V
Power Dissipation Max
400W
Collector Emitter Voltage V(br)ceo
600V
Power Dissipation Pd
200W
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Test
cate-
gories
1 High temperature
2 High temperature
3 High temperature
4 Intermitted
(for Collector-Emitter)
(for Cathode Anode)
(Power cycle)
( for IGBT )
Reverse Bias
Bias (for gate)
Reverse Bias
Operating Life
Test items
Electrical
Visual
Note : Each parameter measurement read-outs shall be made after stabilizing the components
characteristic
inspection
Item
at room ambient for 2 hours minimum, 24 hours maximum after removal from the tests.
at room ambient for 2 hours minimum, 24 hours maximum after removal from the tests.
And in case of the wetting tests, for example, moisture resistance tests, each component
And in case of the wetting tests, for example, moisture resistance tests, each component
shall be made wipe or dry completely before the measurement.
shall be made wipe or dry completely before the measurement.
Each parameter measurement read-outs shall be made after stabilizing the components
Test temp.
Bias Voltage
Bias Method
Test duration
Test temp.
Bias Voltage
Bias Method
Test duration
Test temp.
Bias Voltage
Bias Method
Test duration
ON time
OFF time
Test temp.
Number of cycles
Leakage current
Gate threshold voltage VGE(th)
Saturation voltage
Forward voltage
Thermal
Isolation voltage
Visual inspection
resistance
Peeling
Plating
and the others
Characteristic
IGBT
FWD
Test methods and conditions
Reliability Test Items
: Ta = 125±5 ℃
: VC = 0.8×VCES
: Applied DC voltage to C-E
: 1000hr.
: Ta = 125±5 ℃
: VC = VGE = +20V or -20V
: Applied DC voltage to G-E
: 1000hr.
: Ta = 125±5 ℃
: VC = 0.8×VRRM
: Applied AC half-wave voltage to K-A
: 1000hr.
: 2 sec.
: 18 sec.
:
: 15000 cycles
Failure Criteria
VGE = 0V
VCE = 0V
Tj ≦ 150 ℃, Ta=25±5 ℃
VCE(sat)
or
Symbol
(Tj ≦ 150 ℃)
(Tj ≦ 150 ℃)
(Tj ≦ 150 ℃)
Tj=100±5 deg
±IGES
ICES
Viso
VF
VGE
VF
-
VCE
Lower limit Upper limit
LSL×0.8
The visual sample
Broken insulation
Failure criteria
-
-
-
-
-
-
LSL : Lower specified limit.
USL : Upper specified limit.
USL×1.2
USL×1.2
USL×1.2
USL×1.2
USL×1.2
USL×2
USL×2
MS6M0880
Unit
mA
mA
mV
mV
V
V
-
-
A
Reference norms
(Aug.-2001 edition)
Test Method 101
Test Method 101
Test Method 101
Test Method 106
EIAJ ED-4701
Note
Number
sample
H04-004-03a
of
5
5
5
5
9
16
Accept-
ance
number
( 0 : 1 )
( 0 : 1 )
( 0 : 1 )
( 0 : 1 )
a