Datasheet

Specifications of PM100CLA120

Module Configuration
Six
Transistor Polarity
N Channel
Dc Collector Current
100A
Collector Emitter Voltage Vces
1.2kV
Power Dissipation Pd
601W
Operating Temperature Range
-20°C To +150°C
No. Of Pins
19
Configuration
3 Phase Inverter
Current
100A
Voltage
1200V
Voltage - Isolation
2500VDC
Package / Case
Module
Distributorinventory
View
Circuit Configuration
6-Pac
Package
135x110mm
Rohs Compliant
Yes
Recommended Accessory
BP7B-LB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
BP7A-LB - KIT DEV INTERFACE FOR IPM
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM100CLA120
Manufacturer:
HITACHI
Quantity:
201
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM100CLA120
Intellimod™ L-Series
Three Phase IGBT Inverter
100 Amperes/1200 Volts
Electrical and Mechanical Characteristics, T
Characteristics
IGBT Inverter Sector
Collector-Emitter Cutoff Current
Diode Forward Voltage
Collector-Emitter Saturation Voltage
Inductive Load Switching Times
Control Sector
Short Circuit Trip Level
Short Circuit Current Delay Time
Over Temperature Protection
(Detect T
Supply Circuit Under-voltage Protection
(-20 ≤ T
Circuit Current
Input ON Threshold Voltage
Input OFF Threshold Voltage
Fault Output Current*
Fault Output Pulse Width*
*Fault output is given only when the internal SC, OT and UV protections schemes of either upper or lower devide operate to protect it.
j
≤ 125°C)
j
of IGBT Chip)
V
Symbol
t
V
V
I
I
t
t
off(SC)
CE(sat)
I
FO(H)
C(on)
C(off)
OT
UV
FO(L)
V
th(on)
th(off)
CES
t
SC
OT
UV
t
t
I
FO
t
EC
on
off
rr
D
R
R
j
= 25°C unless otherwise specified
V
P
V
V
-I
-V
V
CE
V
V
V
D
C
CE
D
D
-20°C ≤ T
D
VPC
= 15V, V
Applied between U
= 100A, V
= V
= 15V, V
= 15V, V
V
= 15V, V
= V
V
D
V
V
, W
CC
D
D
CES
= 15V, V
CES
Test Conditions
= 15V, V
= 15V, V
P
= 600V, I
Reset Level
Reset Level
-V
T
T
CIN
, V
j
V
Trip Level
Trip Level
V
T
, V
CIN
CIN
≤ 125°C, V
CIN
j
j
CIN
WPC
j
D
D
= 125°C
= 125°C
D
= 25°C
D
= 15V
= 15V, V
= 15V
CIN
= 15V, T
= 0V, I
= 0V, I
= 15V, V
= 15V, T
= 15V, V
CIN
CIN
, U
C
= 0 15V
N
= 100A
= 15V
= 15V
P
- V
C
C
D
-V
XP1
= 100A,
= 100A,
N1
N
j
j
= 15V
D
UPC
= 125°C
- W
= 25°C
-V
-V
= 15V
NC
XPC
,
N
-V
NC
Min.
11.5
200
135
0.5
1.2
1.7
1.0
12.0
12.5
145
125
Typ.
2.5
1.8
1.9
1.0
0.5
0.4
2.0
0.7
0.2
1.5
2.0
1.8
18
10
6
Max.
12.5
0.01
155
1.0
3.5
2.3
2.4
2.5
0.8
1.0
3.0
1.2
1.8
2.3
10
28
12
15
Amperes
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Units
mA
mA
mA
mA
mA
mA
ms
µs
µs
µs
µs
µs
µs
°C
°C
3

Related parts for PM100CLA120