PM10-12S03 TDK Corporation, PM10-12S03 Datasheet

no-image

PM10-12S03

Manufacturer Part Number
PM10-12S03
Description
DC/DC CONVERTER IN 9-18V OUT 3.3
Manufacturer
TDK Corporation
Series
PM10r
Type
Isolatedr
Datasheet

Specifications of PM10-12S03

Output
3.3V
Number Of Outputs
1
Power (watts)
8W
Mounting Type
Through Hole
Voltage - Input
9 ~ 18V
Package / Case
5-DIP Module
1st Output
3.3 VDC @ 2.55A
Size / Dimension
2.00" L x 1.00" W x 0.34" H (50.8mm x 25.4mm x 8.6mm)
Power (watts) - Rated
8.4W
Operating Temperature
-40°C ~ 105°C
Efficiency
74%
3rd Output
-
2nd Output
-
4th Output
-
Other names
PM1012S03
Q1120189

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM10-12S03
Manufacturer:
LAMBDA
Quantity:
12 000
Installation Data Sheet
PM10-12S DC-DC Converters
The PM10 is a DC-DC converter which provides a regulated output at power levels up to 10 watts. It accepts a wide range DC
input and provides a fully isolated, regulated output. In operation, either (or neither) input pin, as well as either (or neither)
output pin can be grounded. PM10 units provide full output power for ambient temperatures up to 70°C, with linear derating
from 70°C to zero power at 105°C. In forced air applications, full output power can be maintained as long as the chassis
temperature, as measured in the center of the unit’s label, is maintained at less then or equal to 100°C.
Note : For safety agency approval of the end use equipment to safety standards (such as UL 1950 3
C22.2 No. 950-95, DIN VDE 0805 and EN 60950), the output of the converter is ELV if the input to the converter is ELV; the
output of the converter is SELV only if its input is SELV. The input and output are to be both floating or both grounded. The
converter is to be protected by the specified fuse, provided in the ungrounded leg.
Specifications:
*To Avoid current limit circuit activation into a capacitive load with no series impedance. Assumes full constant DC load
parallel with capacitance at minimum input line voltage.
**Regulatory Agency compliance testing is in process. Check individual unit’s label for appropriate
agency logos.
Note: Regulation values pertain to operation with output currents above 10% of rated load current.
Nominal Output Voltage
Voltage Accuracy
Output Current (Power) @ 70°C
Operating Temperature Range
Output Voltage Adjustment Range
Output Ripple (20MHz BW)
Line Regulation
Load Regulation (10% - 100%)
Temperature Coefficient
Overshoot
Input Voltage Range
Efficiency (Typical)
No Load Input Power
Conducted EMI
Short Circuit Protection
Max Load Capacitance*
Overvoltage Clamp Point (fixed)
Isolation (Input to Output)
Regulatory Agency Compliance**
Mounting & Connections
Cover
Size (W.H.D.)
Storage Temperature
Cooling
Vibration
Relative Humidity
Altitude
Fungus Proofing
Thermal Cycling
Warranty
ITEMS
MODEL
A/W
MV
mV
mV
W
%
V
V
V
in
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
PM10-12S SERIES
-25°C to + 105°C. Derate linearly above + 70°C to 0 watts at 105°C
1 hour @ -25°C ramped to 1 hour @ +25°C ramped to 1 hour @ +100°C, 10
cycles ramp = 5°C / minute
No overshoot at turn on, turn off, power failure or removal of a short circuit
ETSI-300, Bellcore TR-TSY-001003, UL1950 3
PM10-12S03
2.55 (8.4)
EN55022 Level B, FCC Level B, ANSI 63.12-1987 with external filter
4.7 max.
750uF
2.5G RMS,10Hz – 50 Hz, random vibration, 10 minutes per axis
3.3
6.6
33
74
20mV RMS / 75 mVp-p
10,000 feet max. operating / 45,000 feet max. storage
0.040” diameter, 0.22” long solderable pins
Convection cooling allows full o/p rating.
2 year warranty includes parts and labor
No. 950-95, EN 60950, VDE 0805
Output is Fixed, or not adjustable
Units are inherently fungus inert
PM10-12S05
2.00 (10.0)
5% - 95%, non-condensing
0.032” anodized aluminum
6.5 max.
500Vac, 700Vdc, 10M
470uF
10
50
1.0” x 2.0” x 0.335”
5
-40°C to + 105°C
± .01% / °C
Continuous
9 – 18 Vdc
± 1%
0.4
LAMBDA ELECTRONICS INC.
LAMBDA ELECTRONICS INC.
LAMBDA ELECTRONICS INC.
LAMBDA ELECTRONICS INC.
PM10-12S12
0.83 (10.0)
14 max.
25mV RMS / 100 mVp-p
76
68uF
rd
120
12
24
IM-PM1012S 7/99 REV: B
Edition, CAN/CSA C22.2
rd
Edition, CAN/CSA
PM10-12S15
17.5 max.
.67 (10.0)
68uF
150
15
30

Related parts for PM10-12S03

PM10-12S03 Summary of contents

Page 1

... Agency compliance testing is in process. Check individual unit’s label for appropriate agency logos. Note: Regulation values pertain to operation with output currents above 10% of rated load current. PM10-12S SERIES MODEL PM10-12S03 PM10-12S05 V 3.3 - A/W 2 ...

Page 2

... Input fuse must be connected in series with the ungrounded input lead. Mechanical Information: PM10 units are designed for installation on printed wiring boards. The metal chassis has 0.015” taps built in to provide clearance between the pins and the PC board to allow for wave soldering. During wave soldering, the top surface of the board to which the PM unit is mounted (measured ½ ...

Related keywords