60212 SQUARE D, 60212 Datasheet - Page 156

CIRCUIT BREAKER, THERMAL MAG, 1P, 15A

60212

Manufacturer Part Number
60212
Description
CIRCUIT BREAKER, THERMAL MAG, 1P, 15A
Manufacturer
SQUARE D
Series
C60Nr
Datasheet

Specifications of 60212

Actuator Style
Toggle
No. Of Poles
1
Current Rating
15A
Voltage Rating Vdc
60V
Voltage Rating Vac
120V
Mounting Type
DIN Rail
Tripping Characteristic
C
Voltage Ac
120V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Vigirex
IEC Rated Vigirex Ground-fault Relays
Selection Table
156
Vigirex Ground-fault Relays
Toroids
Electrical Characteristics
I∆n residual operating current
Time delay (ms)
Alarm pre-trip
Device tests
Reset
Local indication
Output contacts
Max. consumption
Control voltage operating range
Toroids to be used ➀
Dimensions and Weights
Dimensions H x W x D (in./mm)
Weight (lb/kg)
Used in conjunction with a standard Merlin Gerin toroid (type A or OA), this type of relay trips the associated switching device, after the selected time
delay, when it detects a residual current above the set residual operating current (I∆n/2).
Characteristics
c Green LED indicates presence of control voltage;
c Red LED indicates the trip threshold has been exceeded;
c Orange LED indicates the alarm threshold has been exceeded (AP);
c Failure of the detection circuit (connecting cable and toroid) trips the circuit breaker.
Advantages
c Protection can be adapted to any installation;
c Vertical coordination possible over a number of levels;
c An alarm threshold provides a warning of a non-critical degradation of the insulation, leaving time to carry out preventive maintenance;
c Control voltage alarm via fail-safe contact
Installation
c Live part in a disconnectable, insulating molded case, eight 9mm modules wide, with sealable transparent cover;
c Horizontal or vertical flush or surface mounting on a symmetrical rail;
c Connection by tunnel terminals for wire sizes:
d 1.5mm
d 2.5mm
Refer to catalog no.: AC0480EN
➀ By shielded wire or toroid plugged into relay for TA30 and PA50—maximum lengths: refer to catalog AC0480EN
2
2
for terminals 1 to 6.
for terminals 7 to 14.
TM
Ground-fault Relays
Selector 2
Delay
Local
Automatic
Alarm
Pre-trip contact
Rating
380 to 480 Vac
Selector 1
Threshold
Insulation fault or detection circuit failure indicator light
Fault contacts
48 to 240 Vac and 48 to 300 Vdc
Number
Contact type
Number
Contact type
AC p.f. = 0.7
DC L/R = 0 s
AC
DC
DE2
Changeover (SPDT)
Changeover (SPDT)
380 V
220 V
220 V
120 V
48 V
24 V
Discount
Schedule
—Not UL Listed
RH10A
30 mA or 300 mA
Instantaneous
Electronic + indicator light + contact
Detection circuit
Local, and remote by disconnecting the auxiliary power supply
By indicator light with latching
2: one standard + one fail-safe
Latched
10 A
–15% / + 10%
±20%
Type A, OA
3.2 x 2.8 x 2.6/81 x 72 x 65.5
0.9/0.4
3 A
5 A
0.45 A
0.65 A
2.5 A
5 VA/3 W
4 VA
1
1
2 3 4 5 6
2 3 4 5 6
7
7
50637
MERLIN GERIN
vigirex
RH10A
8
8
9 10 11 12 13 14
9 10 11 12 13 14
on
reset
test

Related parts for 60212