3-5v,12v,12v,3-5v 130W 4.25 Inch X 8.5 Inch W/cover
Manufacturer
Emerson Network Power
Datasheet

Specifications of LPQ173-C

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Ordering Information
Model
Number
LPQ172
LPQ173
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and
4. 4th output adjustable 3.3-25 V factory set at 5 V.
5. *Minimum loads are required when output set below 5 Volts
6. Remote inhibit resets OVP latch
7. LPQ173-C has no convection rating.
Note: -C suffix added to the model number indicates cover option and is limited to 50 °C operation.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”.
3. Specifications are for convection rating at factory settings unless
4. Mounting screw maximum insertion depth is 0.12”.
5. Warranty: 2 year
6. Weight: 2 lb / 0.91 kg
Environmental Specifications
Logic Control
AC power failure
Remote inhibit
Remote sense
DC - OK
Operating temperature: 0° to 50 °C ambient. Derate each output 2.5% per degree from
Storage temperature:
Temperature coefficient: ±0.4% per °C
Electromagnetic
susceptibility:
Humidity:
Vibration:
MTBF demonstrated:
load ranges.
otherwise stated.
Output
Voltage
5 V (3.3 - 5.5 V)
12 V
-12 V (-12 -15 V) 0 A
±3.3-25 V
5 V (3.3 - 5.5 V)
12 V
-12V (-12 -15 V)
5 V (3.3 - 5.5 V)
Minimum
Load
0 A
0 A
0.5 A*
0 A
0 A
0 A
0 A
TTL logic signal goes high 100 - 500 msec after V1 output; It
goes low at least 4 msec before loss of regulation
Requires contact closure to inhibit outputs
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
TTL logic signal goes high after main output is in regulation. It
goes low when there is a loss of regulation.
50° to 70 °C (except for -C version).
-40°C to +85°C
Designed to meet IE61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3
Operating; non-condensing 5% to 95%
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at
four major resonances 0.75G peak 5Hz to 500Hz, operational
>550,000 hours at full load and 25°C ambient conditions
Maximum
Load with
Convection
Cooling
15 A
6 A
1.5 A
2 A
10 A
6 A
.2 A
10 A
Maximum
Load with
30CFM
forced Air
30 A
8 A
3 A
5 A
24 A
8 A
3 A
24 A
Peak Load 1 Regulation 2
32 A
10 A
3.5 A
5.5 A
26 A
10 A
3.5 A
26 A
±2%
±3%
±3%
±3%
±2%
±3%
±3%
±2%
Ripple P/P
(PARD) 3
50 mV
120 mV
<1%
<50mV or 1%
50 mV
120 mV
<1%
50 mV
Embedded Power for
Business-Critical Continuity
LPQ170 Series
Rev. 07.01.08
2 of 4

Related parts for LPQ173-C