DS1200-3-003 Emerson Network Power, DS1200-3-003 Datasheet - Page 2

no-image

DS1200-3-003

Manufacturer Part Number
DS1200-3-003
Description
12V Output, 1200W 1U X 2U X 11" With Reverse Air
Manufacturer
Emerson Network Power
Datasheet

Specifications of DS1200-3-003

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Environmental Specifications
Logic Control
Ordering Information
*Over current latches off if overcurrent lasts over 1 seconds, otherwise it is auto recovery.
**Release in April 2010
† Derating may apply.
Operating temperature:
Storage temperature:
Altitude, operating:
Electromagnetic susceptibility / Input transients:
RoHS & lead-free compliant:
Humidity:
Shock and vibration specificatons:
MTBF (Demonstrated):
PS_SEATED (A4):
PWR GOOD (C3):
AC OK (B1):
PS_INHIBIT/PS_KILL (B4):
PS ON (A1):
DS1200-3-003**
DS1200-3-004**
Model Number
DS1200-3-002
1400
1200
1000
800
600
400
200
DS1200-3
0
0
5
10
Voltage Set Point
Nominal Output
15
12.0 Vdc
12.0 Vdc
12.0 Vdc
12.0 Vdc
20
25
STANDARD AIR DERATING
TTL logic LOW if power supply is seated into system connector. This is a short pin. A logic HIGH if
the PSU is removed
A low logic level if the input voltage is within allowable limits. A TTL logic HIGH level, and a 5mS
early warning signal before 12.0 V DC output loss of regulation.
When left open power supply operation will be inhibited. When the power supply is
inserted into the system, this pin will be pull low by the system and turn the power supply on only
after all other power supply pins have seated.
The output will be enabled when this signal is pulled low, below 0.8 V outputs disabled when pin
is driven high or left open.
Active TTL high when output is within regulation limits.
30
AMBIENT DEG C
35
Tolerance
Set Point
±0.2%
±0.2%
±0.2%
±0.2%
40
45
50
Regulation
Total
55
±5%
±5%
±5%
±5%
60
65
Minimum
Current
-10° to 50 °C
-40 °C to +85 °C
10,000 ft
-EN61000-3-2, -3-3
-EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level
-EN55024:1998
No tantalum caps.
20 to 90% RH, non-condensing
Complies with Astec Std. Specifications, Q3205
500K Hrs at full load, 40 °C
70
0 A
0 A
0 A
0 A
75
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
Maximum
Current
100 A
100 A
100 A
100 A
180 - 264 Vac
90 - 179 Vac
5 Vsb
Output Ripple
120 mV
120 mV
120 mV
120 mV
1400
1200
1000
P/P
800
600
400
200
0
0
118 A - 147.6 A*
118 A - 147.6 A*
118 A - 147.6 A*
118 A - 147.6 A*
Over Current
Embedded Power for
Business-Critical Continuity
20
Ambient Temperature (
Reverse Air Derating
1140W @ 25 °C
Output Power (W)
3.3 V @ 6 A
5.0 V @ 4 A
3.3 V @ 6 A
5.0 V @ 4 A
Stand-by
25
1025W @ 50 °C
°C
)
50
Air Flow
Rev. 03.15.11_22
REV †
REV †
STD
STD
760W @ 70 °C
70
DS1200
2 of 4
Ou

Related parts for DS1200-3-003