TLP150R-96S48FJ Emerson Network Power, TLP150R-96S48FJ Datasheet - Page 2

POWER SUPPLY, AC/DC, 48V

TLP150R-96S48FJ

Manufacturer Part Number
TLP150R-96S48FJ
Description
POWER SUPPLY, AC/DC, 48V
Manufacturer
Emerson Network Power
Datasheet

Specifications of TLP150R-96S48FJ

Power Supply Type
Open Frame
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
3.2A
Power Rating
150W
Input Voltage
85V AC To 264V AC
Length
127mm
Width
76.2mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Environmental Specifications
Conducted emissions:
harmonic current correction:
ESD air:
ESD contact:
Fast transients:
Surge:
Conducted immunity:
Hold-up time:
Efficiency:
Isolation voltage:
Safety approvals:
(see note 6)
Weight:
MTBF (@25 ºC)
Thermal performance:
Relative humidity:
Altitude:
Vibration (See Note 7):
Shock:
EMC Characteristics
General Specifications
Operating ambient,
(See derating curve)
Non-operating
0 °C to 50 °C ambient,
200 LFM forced air
0 °C to 50 °C ambient,
convection cooled
50 °C to 70 °C ambient,
Non-condensing
Operating
Non-operating
5 - 500 Hz
per MIL-STD-810E
EN55022, FCC part 15
EN61000-3-2
EN61000-4-2
EN61000-4-2
EN61000-4-4
EN61000-4-5
EN61000-4-6
85 Vac @ 60 Hz
115 Vac @ 150 W
230 Vac @ 150 W
Input/output
Input/chassis
UL/cUL UL60950-1/CSA22.2 No. 60950-1
VDE EN60950-1/IEC60950-1
260g (9.2 oz)
Telcordia SR-332
MIL-HDBK-217F
Level B
Compliant
Level 3
Level 3
Level 4
Level 4
Level 3
20 ms @ 150 W
81% typ.
84% typ.
3000 Vac
1500 Vac
900,000 hours min.
350,000 hours min.
0° C to +70 °C
-40 °C to +85 °C
150 W
100 W
Derate linearly to 50% load
5 - 95% RH
10,000 feet max.
30,000 feet max.
2.4 G rms peak
516.4 Part IV
Embedded Power for
Business-Critical Continuity
Rev.7.8.09_146
TLP150
 of 4