MP4-2E-1N-1N-03 Emerson Network Power, MP4-2E-1N-1N-03 Datasheet - Page 3

no-image

MP4-2E-1N-1N-03

Manufacturer Part Number
MP4-2E-1N-1N-03
Description
POWER SUPPLY, SWITCH MODE
Manufacturer
Emerson Network Power
Datasheet

Specifications of MP4-2E-1N-1N-03

Input Voltage
85V AC To 264V AC / 120V DC To 350V DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Non-std*
2.4 V -2.7 V
3.6 V - 4.5 V
6.6 V -9.2 V
8.8 V - 9.0 V
Output Module Voltage/Current
Ordering Information
Voltage
8.0 V
2.2 V
3.3 V
5.2 V
5.5 V
6.0 V
Case Size (mm)
4 = 2.5” x 5” x 10”; 400 W-600 W, 5 Slots
6 = 2.5” x 5” x 11”; 600 W-800 W, 5 Slots
8 = 2.5” x 7” x 10”; 800 W-1000 W, 6 Slots
1 = 2.5” x 8” x 11”; 1000 W-1200 W, 7 Slots*
10 V
11 V
12 V
14 V
15 V
18 V
20 V
24 V
28 V
30 V
33 V
36 V
42 V
48 V
54 V
60 V
2 V
3 V
5 V
(63.5 x 127 x 254)
(63.5 x 127 x 279.4)
(63.5 x 177.8 x 254)
(63.5 x 203.2 x 279.4)
Voltage
Code
W
M
O
Q
A
C
D
G
H
K
N
R
U
V
X
Y
Z
B
E
F
L
P
S
T
I
J
Case Size
MP1
10.5 A
Single Output Module Code
8.5 A
6.7 A
6.5 A
6.2 A
5.8 A
4.2 A
4.0 A
3.7 A
3.5 A
35 A
35 A
35 A
35 A
35 A
35 A
34 A
23 A
20 A
18 A
17 A
17 A
14 A
14 A
11 A
35 A
35 A
20 A
18 A
1
12.8 A
10.9 A
7.5 A
7.5 A
6.0 A
6.0 A
60 A
60 A
60 A
60 A
60 A
60 A
58 A
42 A
36 A
32 A
31 A
30 A
20 A
19 A
18 A
15 A
12 A
10 A
36 A
32 A
21 A
Special Voltage - Consult Factory for specifications
60 A
60 A
2
40.5 A
54.5 A
33.3 A
23.5 A
21.4 A
18.2 A
16.6 A
12.5 A
12.5 A
120 A
120 A
120 A
120 A
120 A
115 A
109 A
120 A
120 A
78 A
68 A
60 A
50 A
39 A
30 A
20 A
11 A
10 A
68 A
60 A
3
-3L - 2E - 1Q
Module Codes
Module/Voltage/Option Codes
Module codes:
(None) = 36 W triple O/P (1 slot)
1 = 210 W single O/P (1 slot)
2 = 360 W single O/P (2 slot)
3 = 600 W single O/P (3 slot)
4 = 144 W dual O/P (1 slot)
5 - 9 = future
Voltage Codes:
See Output Module Voltage/
Current table above
10 A
10 A
10 A
10 A
Dual Output**
9 A
8 A
4 A
3 A
V1
Module/Voltage/Option Codes
Second - Voltage Code
First - Module Code
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
10 A
4 A
4 A
4 A
2 A
2 A
4 A
4 A
V2
1 A
1 A
1 A
1 A
1 A
1 A
V1
Triple Output
- 4LL
0.5 A
0.5 A
0.5 A
0.5 A
1 A
1 A
1 A
1 A
1 A
1 A
V2
HUP = Hold up module
VME = VME POR signal
0.5 A
0.5 A
0.5 A
0.5 A
2 A
2 A
2 A
2 A
2 A
2 A
2 A
2 A
1 A
1 A
1 A
1 A
1 A
1 A
2 A
2 A
1 A
1 A
V3
Add-on Modules
- HUP
and isolated DC
Notes:
1. Omit digits that do not apply.
2. Specify modules from lowest number of outputs to highest.
3. If number of outputs are equal, specify modules from highest to
4. Always start with Slot 1.
5. All MP model configurations created using this selection guide are
6. Optional VME/DCOK module must always be located in the last slot.
(Single/Dual/Triple)
lowest power increments. If power increments are equal, specify
in descending alphabetical order (1A, B, C . . .).
standard MP products with standard availability and lead times.
Module designator is “VME”.
Parallel Codes
7
6
Case Option Codes
First digit
0 - 9 = parallel code
(See Parallel Codes table above)
Second digit
Standard Options
0 = No options
1 = Rear Air Exhaust
3 = Global enable
5 = Opt 1 + Opt 3
M = Low Leakage
N = Low Leakage + Opt 1
P = Low Leakage + Opt 3
R = Low Leakage + Opt 5
5 4
Case Option Codes
Embedded Power for
Business-Critical Continuity
- 00
3
2
1
MP4 & MP6
available slots
MP8
available slots
0 = no parallel
1 = 1 & 2
2 = 2 & 3
3 = 3 & 4
4 = 4 & 5
5 = 3 & 4 & 5
6 = 5 & 6
7 = 4 & 5 & 6
8 = 6 & 7
9 = 3 & 4, 6 & 7
A = 1 & 2, 3 & 4, 5 & 6
C = 2 & 3, 4 & 5
E = 3 & 4, 5 & 6
MP1
available slots
Factory assigned
for modifications
Hardware Code
-###
Rev. 10.01.10_89
MP Series
3 of 8

Related parts for MP4-2E-1N-1N-03