UCQ-3.3/30-D48PB-C Murata Power Solutions Inc, UCQ-3.3/30-D48PB-C Datasheet - Page 8

CONVERTER, DC/DC, 3.3V, 30A, Q-BRICK

UCQ-3.3/30-D48PB-C

Manufacturer Part Number
UCQ-3.3/30-D48PB-C
Description
CONVERTER, DC/DC, 3.3V, 30A, Q-BRICK
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of UCQ-3.3/30-D48PB-C

Output Type
Quarter-Brick
No. Of Output Channels
1
Input Voltage
36V To 75V
Power Rating
99W
Output Voltage
3.3V
Output Current
30A
Supply Voltage
48V
Dc / Dc Converter Case Style
Quarter
Dc / Dc Converter O/p Type
Quarter-Brick
No. Of Outputs
1
Approval Bodies
EN / IEC / UL
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Performance Specifications and Ordering Guide ➀
Caution: This product is not internally fused. To comply with safety agency certifications and to avoid injury to personnel or equipment, the user must supply an external fast-blow fuse to the input terminals.
(1) All models are tested and specified with external 1||10 µF ceramic/tantalum output capacitors no external input capacitor. All capacitors are low ESR types. These capacitors are necessary to accom-
(2) Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is C
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions, Tpcboard = +25 deg.C, full output load, natural air convection.
(5) The On/Off Control is normally controlled by a switch or open collector or open drain transistor. But it may also be driven with external logic or by applying appropriate external voltages which are
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting.
(7) The outputs are not intended to sink appreciable reverse current. This may damage the outputs.
(8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise Reduction.
(9) All models are fully operational and meet published specifications, including “cold start” at –40 C.
(10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme.
(11) Output accuracy is dependent on user-supplied trim resistors. To achieve high accuracy, use ±1% or better tolerance metal-film resistors mounted close to the converter.
(12) Output current limit and short circuit protection is non-latching. When the overcurrent fault is removed, the converter will immediately recover.
(13) Do not exceed maximum power specifications when adjusting the output trim.
(14) At zero output current, the output may contain low frequency components which exceed the ripple specification. The output may be operated indefinitely with no load.
(15) Input Fusing: If reverse polarity is accidentally applied to the input, a body diode will become forward biased and will conduct considerable current. To ensure reverse input protection with full output load,
(16) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcurrent condition still exists, the restart current will be removed and then tried again.
Physical
Outline dimensions
Pin material
Pin diameter
Pin finish
Weight, ounces
Weight, grams
Electromagnetic
Safety
Specification Notes
interference
modate our test equipment and may not be required to achieve specified performance in your applications. All models are stable and regulate within spec under no-load conditions. All specifications are
typical unless noted. General conditions for Specifications are +25 deg.C, V
the total RMS current over time does not exceed the Derating curve. All Derating curves are presented at sea level altitude. Be aware of reduced power dissipation with increasing density altitude.
referenced to Input Common.
always connect an external input fast-blow fuse in series with the +V
This short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal operation.
See fuse information.
Physical
Outline dimensions
Pin material
Pin diameter
Pin finish
Weight, ounces
Weight, grams
Electromagnetic
Safety
interference
UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24
1.06
30
UCQ-3.3/20-D48 UCQ-3.3/30-D48
www.murata-ps.com
1.06
0.7
20
30
in
input. Use approximately twice the full input current rating with nominal input voltage.
in
and V
UL 60950-1, CSA C22.2 No.60950-1, IEC/EN 60950-1
UL 60950-1, CSA C22.2 No.60950-1, IEC/EN 60950-1
out
(Conducted and radiated. External filter required)
(Conducted and radiated. External filter required)
= nominal, full load. Adequate airflow must be supplied for extended testing under power.
TBD
TBD
0.9
25
0.04/0.062 inches (1.016/1.524 mm)
0.04/0.062 inches (1.016/1.524 mm)
Nickel underplate with gold overplate
Nickel underplate with gold overplate
in
FCC part 15, class B, EN55022
FCC part 15, class B, EN55022
= 33 µF, 100V tantalum, C
See mechanical specs.
See mechanical specs.
UCQ-5/20-D24
Copper alloy
Copper alloy
1.06
0.9
30
25
Single Output UCQ Models
bus
= 220 µF, 100V electrolytic, L
Technical enquiries email: sales@murata-ps.com, tel:
Low-Profile, Quarter Brick, 8.3-40 Amp
UCQ-5/20-D48
1.06
TBD
TBD
30
Isolated DC/DC Converters
bus
UCQ-12/8.3-D48
= 12 µH.
MDC_UCQ Models.B06 Page 8 of 16
1.06
1.13
32
30
+1 508 339 3000
1.02
29

Related parts for UCQ-3.3/30-D48PB-C