UCQ-3.3/30-D48PB-C Murata Power Solutions Inc, UCQ-3.3/30-D48PB-C Datasheet

CONVERTER, DC/DC, 3.3V, 30A, Q-BRICK

UCQ-3.3/30-D48PB-C

Manufacturer Part Number
UCQ-3.3/30-D48PB-C
Description
CONVERTER, DC/DC, 3.3V, 30A, Q-BRICK
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of UCQ-3.3/30-D48PB-C

Output Type
Quarter-Brick
No. Of Output Channels
1
Input Voltage
36V To 75V
Power Rating
99W
Output Voltage
3.3V
Output Current
30A
Supply Voltage
48V
Dc / Dc Converter Case Style
Quarter
Dc / Dc Converter O/p Type
Quarter-Brick
No. Of Outputs
1
Approval Bodies
EN / IEC / UL
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
FEATURES
n
n
n
n
n
n
n
n
n
n
n
n
Standard quarter-brick package/pinout
Low cost; Low profile, 0.4" (10.2mm)
24V or 48V nominal input
Outputs: 1.2V to 12V
Interleaved synchronous-rectifier topology
• Ultra high efficiency
• No output reverse conduction
Outstanding thermal performance
On/off control, trim & sense functions
Fully isolated, 2250Vdc (BASIC)
Output overvoltage protection
Fully I/O protected; Thermal shutdown
Designed to meet UL/EN/IEC60950-1
safety approvals
Qual/HALT/EMI tested
www.murata-ps.com/rohs
For full details go to
 
CONTROL*
REMOTE
ON/OFF
(2)
+V
–V
(3)
(1)
IN
IN
INPUT UNDERVOLTAGE, INPUT
OVERVOLTAGE, AND OUTPUT
OVERVOLTAGE COMPARATORS
PRODUCT OVERVIEW
For applications requiring improved electrical and
thermal performance at reduced cost, consider
DATEL’s new UCQ series “quarter brick” DC/DC
power converters. These compact units measure
just 1.45" x 2.3" x 0.4" (36.8 x 60.9 x 10.2 mm)
and fit the industry-standard footprint.
to 12V @ 8.3 Amps and accept a wide input range.
The UCQ’s interleaved, synchronous-rectifier
topology offers high efficiency (up to 93%), tight
line and load regulation, low noise and fast step
response. A single-board optimized open-frame
design contributes to impressive thermal opera-
tion. UCQ’s will operate up to +70°C and 100 LFM
airflow with no derating.
www.murata-ps.com
Available outputs range between 1.2V @ 30 Amps
CONTROLLER
PWM
Figure 1. Simplified Schematic
Single Output UCQ Models
* Can be ordered with positive (standard) or negative (optional) polarity.
ISOLATION
CONTROL
SWITCH
Typical topology may vary between units.
OPTO
Technical enquiries email: sales@murata-ps.com, tel:
Low-Profile, Quarter Brick, 8.3-40 Amp
meeting BASIC insulation requirements of
UL/EN/IEC 60950-1. Input filters reduce propa-
gated switching noise back to input sources. Also
included is a remote On/Off switch control (with
positive or negative polarity), output trim adjustable
over nominal and output sense functions to reduce
power lead losses. Extensive protection items
avoid damage from out of limit voltages, currents
and temperatures. Protection faults automatically
recover using the hiccup technique. Besides safety
testing to 60950-1, certifications for the UCQ
include application for EMC compliance (to FCC
class B), qualification testing (including HALT) and
CE marking.
The UCQ’s feature full isolation to 2250Vdc
REFERENCE &
ERROR AMP
Isolated DC/DC Converters
MDC_UCQ Models.B06 Page 1 of 16
Typical units
+1 508 339 3000
+SENSE
+V
–V
–SENSE
TRIM
V
(8)
(4)
(7)
(6)
OUT
OUT
(5)
OUT

Related parts for UCQ-3.3/30-D48PB-C

UCQ-3.3/30-D48PB-C Summary of contents

Page 1

... A single-board optimized open-frame design contributes to impressive thermal opera- tion. UCQ’s will operate up to +70°C and 100 LFM airflow with no derating. PWM CONTROLLER INPUT UNDERVOLTAGE, INPUT ...

Page 2

... Technical enquiries email: sales@murata-ps.com, tel: MDC_UCQ Models.B06 Page Efficiency Min. Typ. 81% 83% 81% 83% 85% 86% 83% 86% 82% 84% 85% 87% 87% 89% 88.5% 90% 90% 91% 88% 91.5% 89% 93% 90% 91% +1 508 339 3000 ...

Page 3

... PINS 4, 8: (4.6) 0.060Ø ±0.001 (1.524 ±0.025) I/O Connections Pin Function P32 Pin Function P32 1 −Input 5 2 Remote On/Off 6 3 +Input 7 4 −Output 8 Technical enquiries email: sales@murata-ps.com, tel: MDC_UCQ Models.B06 Page −Sense Output Trim +Sense +Output +1 508 339 3000 ...

Page 4

... Performance Specifications and Ordering Guide ➀ UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24 Input Input voltage range Start-up threshold, Volts 34 Undervoltage 33 shutdown, V Overvoltage shutdown Reflected (back) ripple current, mA pk-pk Input Current Full load conditions Inrush transient sec Output short circuit load, mA Low line (V = min ...

Page 5

... V range per °C. out No minimum loading. +10% See ordering guide. See ordering guide. See ordering guide. 10,000 10,000 10,000 Technical enquiries email: sales@murata-ps.com, tel: Isolated DC/DC Converters UCQ-12/8.3-D48 35 34 3.04 L-C 10,000 +1 508 339 3000 MDC_UCQ Models.B06 Page ...

Page 6

... Performance Specifications and Ordering Guide ➀ UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24 Isolation Voltage Input to Output, Volts min. Input to baseplate, Volts min. Baseplate to output, Volts min. Isolation resistance, MΩ Isolation capacitance, pF Isolation safety rating Miscellaneous Current limit inception (98 after 35 out ...

Page 7

... TBD −40 to +85, with derating −40 to +110 −55 to +125 110-125, model dependent To +85°C/85%, non-condensing Technical enquiries email: sales@murata-ps.com, tel: Isolated DC/DC Converters UCQ-12/8.3-D48 10 TBD 14.4 200 µSec to ±1% of final value 50 50 330 ± 508 339 3000 MDC_UCQ Models.B06 Page ...

Page 8

... Performance Specifications and Ordering Guide ➀ UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24 Physical Outline dimensions Pin material Pin diameter Pin finish Weight, ounces 1.06 Weight, grams 30 Electromagnetic interference Safety Physical Outline dimensions Pin material Pin diameter Pin finish Weight, ounces ...

Page 9

... The UCQ Series implements a soft start circuit to limit the duty cycle of its PWM controller at power up, thereby limiting the input inrush current. ...

Page 10

... See Performance/Functional Specifications. Output Over-Voltage Protection The UCQ output voltage is monitored for an over-voltage condition using a com- parator. The signal is optically coupled to the primary side and if the output volt- age rises to a level which could be damaging to the load, the sensing circuitry will power down the PWM controller causing the output voltage to decrease ...

Page 11

... OUT OUT Trimming Output Voltage UCQ converters have a trim capability (pin 6) that enables users to adjust the output voltage (refer to the trim equations and trim graphs that follow). Adjust- ments to the output voltage can be accomplished via a trim pot (Figure single fixed resistor as shown in Figures 6 and 7. A single fixed resistor can increase or decrease the output voltage depending on its connection. Resistors should be located close to the converter and have TCR’ ...

Page 12

... Applying an external voltage to pin 2 when no input power is applied to the converter can cause permanent damage to the converter. can be added to out www.murata-ps.com Single Output UCQ Models Low-Profile, Quarter Brick, 8.3-40 Amp Isolated DC/DC Converters Typical Performance Curves Technical enquiries email: sales@murata-ps.com, tel: MDC_UCQ Models.B06 Page 508 339 3000 ...

Page 13

... UCQ-1.2/30-D48 Efficiency vs Line Voltage and Load Current @25˚ 48V 75V Load Current (Amps) UCQ-1.5/25-D48 Efficiency vs Line Voltage and Load Current @25˚ 75V 48V 36V Load Current (Amps) UCQ-1.8/30-D48 Efficiency vs Line Voltage and Load Current @25˚ 36V 48V 75V Load Current (Amps) Typical Performance Curves UCQ-1 ...

Page 14

... UCQ-2.5/30-D48 Efficiency vs Line Voltage and Load Current @25˚ 75V 48V 36V Load Current (Amps) UCQ-2.5/40-D24 Efficiency vs Line Voltage and Load Current @25˚ 24V 35V Load Current (Amps) UCQ-3.3/30-D48 Efficiency vs Line Voltage and Load Current @25° 50V 75V Load Current (Amps) Typical Performance Curves UCQ-2 ...

Page 15

... UCQ-3.3/30-D48 Maximum Current Temperature Derating With baseplate 48V (at sea level 100 lfm 15 200 lfm 10 300 lfm 5 400 lfm 0 Ambient Temperature (°C) UCQ-3.3/35-D24 Efficiency vs Line Voltage and Load Current @25˚ 36V 24V 18V Load Current (Amps) UCQ-5/20-D48 Efficiency vs Line Voltage and Load Current @25°C ...

Page 16

... UCQ-12/8.3-D48 Efficiency vs Line Voltage and Load Current @25˚ 75V 48V 36V 0.8 1.6 2.4 3.2 4 Load Current (Amps) Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights ...