LGB00100 Red Lion Controls, LGB00100 Datasheet - Page 2

no-image

LGB00100

Manufacturer Part Number
LGB00100
Description
Four Preset Batch, W/Red Bkltng
Manufacturer
Red Lion Controls
Type
Counterr
Datasheet

Specifications of LGB00100

Accuracy
±0.01% %
Cut Out, Panel
2.68×2.68 "
Dimensions
5.87"L×2.95"W×2.95"H
Display Digit Height
0.3 "
Display Type
LCD
Function
Counter
Material, Casing
Plastic
Number Of Digits
2×8
Primary Type
Electronic
Range, Measurement
-99999 to 999999
Termination
Plug-In Terminal
Voltage, Supply
115/230 VAC, +12 VDC
Sealing
NEMA 4X/IP65
Power Requirements
115/230 VAC, 12 VDC
Operating Temperature
0°C to 50°C
Panel Cutout
2.68" × 2.68"
Lead Free Status / Rohs Status
RoHS Compliant part
DESCRIPTION (Cont’d)
Count display (Process, Batch, or Total) is exceeded, by flashing the word
“OVERFLOW” in the appropriate display.
removed in nonvolatile memory.
and control inputs to other RLC products, provides added versatility for stand-
alone and system counter needs.
value. This method insures high resolution at all input rates. The unit counts
input pulses and after the programmable minimum update time elapses and the
next count edge occurs, the unit will take the number of edges that occurred
during the elapsed time to calculate the rate value. The minimum update time
can be as low as 0.1 second per update, enabling quick response to rate changes.
At slower rates, averaging can be accomplished by programming the Minimum
and Maximum Update Time for the desired response. Extensive scaling
capabilities allow practically any reading at very slow input rates.
case with a clear viewing window. The sealed front panel with the silicone
rubber keypad meets NEMA 4X/IP65 specifications for wash-down and/or
dusty environments, when properly installed. Plug-in style terminal blocks
simplify installation and wiring change-outs.
SAFETY SUMMARY
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
not equipped with safeguards. To do so, can be potentially harmful to persons
or equipment in the event of a fault to the unit.
MODELS - LGS & LGD
unit has two outputs which are activated from presets 1 and 2 respectively. Each
output can be assigned to either Rate or Count display. An optional relay board
can be installed that operates in parallel with the solid state output(s).
MODEL - LGB
batch. Presets 1 and 2 are assigned to the Process Counter and activate relay
outputs 1 and 2 respectively.
indicator. Presets 3 and 4 activate the NPN open collector outputs O3-SNK and
O4-SNK respectively.
MODEL - LGM
outputs 01-SNK to 06-SNK respectively. Preset one through four are assigned
to the count display. Presets 5 and 6 can be assigned to either the Rate or Count
display.
SPECIFICATIONS
1.
2. POWER:
3. MEMORY: Non-volatile memory retains all programming information.
4. SENSOR POWER: +12 VDC ±25% @ 100 mA.
5. INPUTS A and B: DIP Switch selectable to accept count pulses from a
A Legend unit will indicate an overflow condition when the capacity of a
All count values and program setting are retained when unit power is
The choice of several reset cycle modes along with the compatibility of count
The rate input uses the time interval method (1/tau) to calculate the rate
The construction of the Legend series is a light weight high impact plastic
All safety related regulations, local codes and instructions that appear in the
Do not use this unit to directly command motors, valves, or other actuators
The single preset unit has one NPN open collector output and the dual preset
The process counter is used to monitor the progress of the count within the
Presets 3 and 4 can be assigned to either the Batch Counter, Totalizer, or Rate
The Multi Preset unit has six Presets (1-6) which control NPN open collector
DISPLAY: 2x8, 0.3" (7 mm) high characters, negative image transmissive
LCD, with yellow/green or red LED backlighting.
AC Operation: 115/230 VAC ±10%, 50/60 Hz, 10 VA, switch selectable.
DC Operation: +12 VDC ±20% @ 250 mA.
Count and Preset values are written to non-volatile memory when power is
interrupted. All other programming parameters are written to memory when
programming mode is exited. If power is removed while in the programming
menus, the parameters are restored to previously saved settings.
Data Retention: 10 years minimum
variety of sources including switch contacts, outputs from CMOS or TTL
circuits, and all standard RLC sensors.
LOGIC: Input trigger levels V
(1 Preset)
Current sinking: Internal 7.8 KΩ pulled up internally to +12 VDC,
VALLEY
COUNT
PEAK
RATE
LGS
AVAILABLE INDICATION DISPLAYS AND PRESETS FOR EACH MODEL
I
MAX
= 1.6 mA.
(2 Presets)
VALLEY
COUNT
RATE
PEAK
LGD
IL
= 1.5 V
PROCESS
(4 Presets)
MAX
VALLEY
BATCH
TOTAL
RATE
PEAK
LGB
; V
IH
= 3.75 V
MIN
(6 Presets)
VALLEY
COUNT
PEAK
RATE
LGM
.
6. RATE ACCURACY: ±0.01%
7. RATE MINIMUM INPUT FREQUENCY: 0.01 Hz.
8. MAXIMUM COUNT RATE IN KHz:
9. CONTROL INPUTS:
10. SERIAL COMMUNICATIONS:
11. OUTPUT(S):
12. CERTIFICATIONS AND COMPLIANCES:
MODEL
LGS (Single Preset)
LGD (Dual Preset)
LGB (Batch)
LGM (Six Preset)
MAGNETIC PICKUP:
Notes:
1. Maximum count rates given are for Process counter set for Auto reset with
2. Maximum count rate given for X2 & X4 count modes are given for 50%
*Inputs A & B count rates summed.
Programmable user inputs (3): Internal 10 KΩ pull-up to +5 VDC,
Inhibit: Internal 10 KΩ pull-up to +5 VDC, V
Type: RS-485 Multi-point Balanced Interface (2 Wire).
Baud Rate: Programmable from 1200 to 9600.
Maximum Addresses: Programmable from 00 to 99.
Transmit Delay: Programmable for 0.002 or 0.100 second.
Data Format: 10 Bit Frame; 1 start bit, 7 data bits, 1 parity bit, and 1 stop
Solid-State: Current sinking NPN open collector transistor.
Relay(s): Mounted on field-replaceable P.C. board. Form C contacts rated at
Programmable Timed Output(s): Programmable time ranges from 0.01 to
SAFETY
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
RF conducted interference
Power frequency magnetic fields
Emissions to EN 50081-2
RF interference
Current sourcing: Internal 3.9 KΩ pull-down, 7.3 mA @ 28 VDC
Debounce: Damping capacitor provided for switch contact bounce.
Sensitivity: 200 mV peak.
Hysteresis: 100 mV.
Input impedance: 3.9 KΩ @ 60 Hz.
Maximum input voltage: ±50 Vp
Note: For magnetic pickup input, the sink/source DIP switch must be in
the auto cycle preset set to an equivalent of 100 count pulses or greater.
With auto cycle presets less than 100 count pulses, with Count SF =
0.5000 and Count Scale Multiplier = X1, would be 50.
duty cycle signals and Quad signals with 90
V
(Can connect up to 32 units on a single pair of wires)
(Actual number on a single pair of wires is limited by serial hardware
specifications)
bit. Parity is programmable for either ODD, EVEN, or No Parity.
V
(Internal Zener Diode Protection).
5 amps @ 120 VAC/240 VAC or 28 VDC (resistive load), 1/8 H.P. @ 120
VAC (inductive load). The operate time is 5 msec nominal and the release
time is 3 msec nominal.
99.99 seconds, ±0.05% - 11 msec max.
UL Recognized Component, File #E137808, UL508, CSA 22.2 No. 14
IECEE CB Scheme Test Certificate # UL1581-176645/USA,
IL
CE
Limits count speed to 50 Hz and input pulse widths to 10 msec min.
the SRC position.
Recognized to U.S. and Canadian requirements under the Component
Type 4X Indoor Enclosure rating (Face only), UL50
CB Scheme Test Report # 97ME50052-081391
IEC 61010-1, EN 61010-1: Safety requirements for electrical
IP65 Enclosure rating (Face only), IEC529
= 1.0 V
= 1V
Recognition Program of Underwriters Laboratories, Inc.
Issued by Underwriters Laboratories, Inc,
equipment for measurement, control, and laboratory use, Part 1.
SAT
MAX
@ 100 mA max. V
; V
X1
23
20
17
15
IH
CNT + DIR
= 4.0 V
X2
10
11
8
7
MIN
EN 61000-4-2
EN 61000-4-3 Level 3; 10 V/m
EN 61000-4-4 Level 4; 2 Kv I/O
EN 61000-4-6 Level 3; 10 V/rms
EN 61000-4-8 Level 4; 30 A/m
EN 55011
OH
, response time = 10 msec.
8.5
X1
9
7
7
= 30 VDC max.
QUAD
X2
7
7
7
7
IL
o
phase shift.
= 1.0
5.5
X4
Level 2; 4 Kv contact
Level 3; 8 Kv air
80 MHz - 1 GHz
Level 3; 2 Kv power
150 KHz - 80 MHz
Enclosure class A
Power mains class A
5
4
3
MAX
ADD/ADD ADD/SUB
; V
X1*
23
20
17
15
IH
= 4.0 V
1
MAX
X1*
12
10
1
9
8
MIN
.
.

Related parts for LGB00100