IMD VD AC
Manufacturer
Red Lion Controls
Datasheet

Specifications of IMD10060

Rohs Compliant
NA
MODEL IMD -
l
l
l
l
l
l
l
l
l
l
l
DESCRIPTION
of input signals and precisely scales them into engineering units. The IMD Volt
Meter accepts inputs from ±2 VDC to ±300 VDC in one of four ranges. The
IMD Current Meter accepts inputs from ±200 µA DC to ±2 A DC in one of five
ranges. A full 6-digit display accommodates nearly any engineering units and
holds large totalization values. State-of-the-art digital circuitry virtually
eliminates errors due to drift. A full complement of option packages are
available to fulfill many process applications.
greatly simplify initial set-up. English Style display prompts and front panel
buttons aid the operator through set-up and operation. A front panel lock-out
menu protects set-up data and operation modes from unauthorized personnel.
Programmable digital filtering enhances the stability of the reading.
Programmable remote input “E1-CON” pin can be utilized to control a variety
of functions, such as totalizing, alarm control, display hold or tare operations.
All set-up data is stored in E
years without power.
integrate signals up to a maximum display value of 999,999. It features
independent scaling and a low signal cut-out to suit a variety of signal
integration applications. Additionally, nine slopes and offsets can easily be
programmed with this option to linearize transducers with non-linear outputs,
such as square law devices. Optional programmable remote input “E2-CON”
pin can be utilized to control a variety of functions, such as totalizing, alarm
control, display hold or tare operations, simultaneously with “E1-CON” pin.
Peak/valley (max/min) reading memory, display hold and a signal re-zeroing
(tare) function are included with this option and they are easily recalled and
controlled by either the front panel or a remote switch. All readings are retained
at power-down.
to operate in a wide variety of modes to suit many control or alarm applications.
INTERNATIONAL HEADQUARTERS
20 Willow Springs Circle, York, Pa. 17402, (717) 767-6511 FAX: (717) 764-0839
Web site- http://www.redlion-controls.com
DIMENSIONS “In inches (mm)”
40,000 COUNT MEASUREMENT RESOLUTION
TWO MODELS TO CHOOSE FROM:
MULTIPLE RANGES (user selectable)
EASY ONE-PASS SCALING
STATE-OF-THE-ART DIGITAL ELECTRONICS FOR GREATER
FULL 6-DIGIT, HIGH VISIBILITY, 0.56” (14.2 mm) HIGH RED LED
PROGRAMMABLE FRONT PANEL LOCK-OUT MENU
INTEGRATOR (totalizer) AND LINEARIZER (optional)
PEAK/VALLEY MEMORY AND TARE (re-zero) FUNCTION (optional)
DUAL ALARM RELAY OUTPUTS (optional)
BI-DIRECTIONAL SERIAL COMMUNICATIONS (Optional)
(can be scaled to ±99,999 display)
ACCURACY AND RELIABILITY
DISPLAY
The Apollo Intelligent Decade Volt and Current Meters accept a wide range
Both models feature a choice of two different scaling procedures which
An optional integrator (totalizer)/linearizer can be used to totalize or
Optional dual relays with parallel solid state outputs are fully programmable
Optional 20 mA loop, bidirectional serial communications provides
IMD1 VOLTAGE METER (accepts ±2 VDC to ±300 VDC input)
IMD2 CURRENT METER (accepts ±200 µA DC to ±2 A DC input)
APOLLO 4½-DIGIT INTELLIGENT METER FOR DECADE VOLT/CURRENT INPUTS
2
RED LION CONTROLS
PROM, which will hold data for a minimum of 10
E-mail- sales@redlion-controls.com
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.1” (53.3) H x 5.5” (140) W.
1
l
l
EUROPEAN HEADQUARTERS
ENGLAND
892 Plymouth Road, Slough, Berkshire SL1 4LP
computer and printer interfacing to extend the capabilities of the indicator. More
than one unit can be connected in the loop with other RLC products which have
serial communications capabilities.
scaled by the user to interface with a host of recorders, indicators and
controllers. The indicator has several built-in diagnostic functions to alert
operators of any malfunction. Extensive testing of noise interference
mechanisms and full burn-in makes the indicator extremely reliable in industrial
environments. The die-cast front bezel meets NEMA 4/IP65 requirements for
washdown applications. Plug-in style terminal blocks simplify installation
wiring and change-outs.
SAFETY SUMMARY
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
not equipped with safeguards. To do so, can be potentially harmful to persons
or equipment in the event of a fault to the unit.
SPECIFICATIONS
1. DISPLAY: 6-digit, 0.56” (14.2 mm) High LED, minus sign displayed for
2. POWER REQUIREMENTS:
3. CONTROLS: Three front panel push buttons for modifying alarm values
4 to 20 mA or 0 to 10 VDC ANALOG OUTPUT (Optional)
NEMA 4/IP65 SEALED METAL FRONT BEZEL
An optional 4 to 20 mA or 0 to 10 VDC re-transmitted analog output can be
All safety related regulations, local codes and instructions that appear in the
Do not use this unit to directly command motors, valves, or other actuators
negative values. “Flashing” display for totalizer overflow. “......” displayed
for input display out of range. “OLOLOL” displayed for input display
overload and “ULULUL” for underload (negative overload).
AC Power: Switch Selectable 115/230 VAC, ±10%, 50/60 Hz, 14 VA
DC Power: 10 to 30 VDC, 9 Watts max., isolated to 300 Vp.
and indicator set-up. Two external inputs for disabling the front panel and
controlling programmable functions.
+44 1753 696888 FAX: +44 1753 696339
PANEL CUT-OUT
BULLETIN NO. IMD-D
DRAWING NO. LP0190
REVISED 3/97

Related parts for IMD10060

IMD10060 Summary of contents

Page 1

... RED LION CONTROLS INTERNATIONAL HEADQUARTERS 20 Willow Springs Circle, York, Pa. 17402, (717) 767-6511 FAX: (717) 764-0839 Web site- http://www.redlion-controls.com MODEL IMD - APOLLO 4½-DIGIT INTELLIGENT METER FOR DECADE VOLT/CURRENT INPUTS 40,000 COUNT MEASUREMENT RESOLUTION l (can be scaled to ±99,999 display) TWO MODELS TO CHOOSE FROM: l IMD1 VOLTAGE METER (accepts ± ...

Page 2

SPECIFICATIONS (Cont’d) 4. INPUT RANGE/RESOLUTION, ACCURACY, INPUT IMPEDANCE AND MAXIMUM INPUT LEVEL: VOLTAGE ACCURACY % OF RANGES/RESOLUTION FULL SCALE ±2.0000 V/0.1 mVDC 0.025% ±20.000 V/1 mVDC 0.1% ±200.00 V/10 mVDC 0.1% ±300.0 V/100 mVDC 0.1% CURRENT ACCURACY % OF RANGES/RESOLUTION ...

Page 3

... A built- source is provided in the transmit loop. Additionally, multiple units and other Red Lion Controls instruments can be serially addressed, with a maximum address capability of 99 units. (Note: There are hardware limitations which restrict this to a lower number of units per serial loop ...

Page 4

... VDC PART NUMBERS FOR AVAILABLE ANALOG ANALOG SUPPLY VOLTAGES OUTPUT OUTPUT * VDC 115/230 VAC NO NO IMD10030 IMD10060 NO NO IMD10130 IMD10160 NO NO IMD10132 IMD10162 NO NO IMD13130 IMD13160 NO NO IMD13131 IMD13161 NO NO IMD13132 IMD13162 YES ...