61F-GP-N AC220 Omron, 61F-GP-N AC220 Datasheet
61F-GP-N AC220
Specifications of 61F-GP-N AC220
61FGPNAC220
Related parts for 61F-GP-N AC220
61F-GP-N AC220 Summary of contents
Page 1
... Full surge protection. Ordering Information Compact plug-in conductive level controller When placing your order, be sure to specify the desired operating voltage. Example: 61F-GP-N2 120 VAC Rated supply voltage ■ Accessories (Order Separately) Selection Guide for Electrode Holders and Separators Electrode Holders ...
Page 2
... Alarm control warning of abnormal or dangerously high or low lev- els. W min. Between electrode E1 and E3 W max. Between electrode E2 and E3 C) max. (at 500 VDC) between power terminals and electrode terminals, and between electrode C 61F-GP-N2 Lock nut Inscription Model Inscription --- F03-03-SUS304 --- 6 F03-03-SUS316 6 ...
Page 3
... Using the low-level probe allows a wide differential between switching a pump on and off, and can avoid excessive pump operation during tank emptying or filling. If this differential is not required, the low-level probe need not be connected Conductive Level Controller Stop P Start E2 Reservoir 61F- GP-N2 91 PF083A 61F-GP-N2 Earth Tank E3 3 ...
Page 4
... BS-1 Width across flats: 20 Terminal bolt SUS304 (M4) P=0.7 Nut (iron 101 BS-1S Width across flats: 20 BS-1S1 Terminal bolt BS-1S2 SUS304 (M4) P=0 101 61F-GP-N2 PS-5S/-5SR Used with mounting bracket 11-dia. Mounting Holes PF1/2 26 27.5-dia. Cast iron Two mounting screws 26-dia. hole 48 20-dia ...
Page 5
... Note that the Conductive Level Controller 61F-GP-N2 is capable of controlling liquids with specific resistances the controller employs a type PS-3S electrode holder with the elec- trode(s) submerged to a depth max ...
Page 6
... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...
Page 7
... Doing so causes malfunctions by getting vulnerable to induction noise. • Shorten the distance for wiring between the model 61F and elec- trode holders as much as possible. Long distance for wiring may causes malfunctions because stray capacitance may influence operation, or abnormal surges or noise may run through electrode circuit(s) ...
Page 8
Cat. No. N071-E1-03 8/06 Specifications subject to change without notice Printed in USA ...