FS1A-C01S IDEC, FS1A-C01S Datasheet - Page 4

Safety Controller

FS1A-C01S

Manufacturer Part Number
FS1A-C01S
Description
Safety Controller
Manufacturer
IDEC
Datasheet

Specifications of FS1A-C01S

No. Of Analog Outputs
11
No. Of Digital Inputs
30
Supply Voltage Dc, Min
20.4V
External Width
72mm
Supply Voltage Max
28.8VDC
External Depth
113.5mm
Supply Voltage Dc, Max
28.8V
Mounting Type
DIN Rail
Rohs Compliant
Yes
Approval Bodies
CULus, CE, TUV
External Height
114.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The Next Generation Safety Controller
Makes safety circuit configuration easier.
The best solution when the system has multiple points re-
quiring complex I/Os, but the use of programmable control-
ler is not desired.
The best solution when configuring a system without using
a safety relay module, or a safety PLC.
The best solution to eliminate the use of safety relay mod-
ules for each component.
The best solution for the control side to monitor which doors
are open, and to see the error status of safety circuits.
The best solution to replace conventional PLCs to control
interlock switches.
4
IDEC offers
IDEC offers
IDEC offers
IDEC offers
IDEC offers
World’s first logic-selecting configuration.
Eight safety circuit logics are provided.
No programming required. Partial Stop–Entire stop
is achieved by selecting a logic circuit. All you need
is to wire the SafetyOne in the same manner as
safety relay modules.
The SafetyOne can be connected to a variety of
inputs such as emergency stop switches and light
curtains.
Outputs safety I/O status and SafetyOne errors.
Solenoid drive output reduces the required I/O
points of a PLC.
Easy circuit configuration by
High
Various safety inputs—
Safety circuit
Easy connection to interlock
(Spring lock type)
performance—partial stop/entire stop
monitoring—circuit diagnosis with monitor outputs
mechanical contacts and electric components
Solenoid
Drive Outputs
Emergency
Stop Switch
Enabling Switch
Grip Switch
Before
Door 1
Emergency
Stop Switch
HS5B
HS5E
· Programming method has to be learned
· Debugging takes time
· Application software is needed
Ladder or function block
programming is not necessary.
logic
switches—solenoid drive output
Safety
Inputs
Interlock Switch
selection—no programming
Door 2
A
B
C
PLC
Light Curtain
Interlock
Switch with
Solenoid
Door 3
After
· Reduces setting
· Easy checking
Non-contact
Interlock Switch
A:
B and C: Partial stop
Solenoid
Drive Outputs
Safety Inputs
Doors 1, 2, 3
Error signals
Entire stop
B
A
A
C
DIP switch
selection
(09/01/07)
Safety
Outputs
PLC