Specifications of FS1A-C01S

No. Of Analog Outputs
11
No. Of Digital Inputs
30
Supply Voltage Dc, Min
20.4V
External Width
72mm
Supply Voltage Max
28.8VDC
External Depth
113.5mm
Supply Voltage Dc, Max
28.8V
Mounting Type
DIN Rail
Rohs Compliant
Yes
Approval Bodies
CULus, CE, TUV
External Height
114.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
When using control start input X17
32
When using manual start input X16
Safety Output Monitor
Safety Output Monitor
Logic 4 Time Chart
Muting Lamp Output
Muting Lamp Output
Manual Start Input
Manual Start Input
(Y0, Y1, Y2, Y3)
(Y0, Y1, Y2, Y3)
Monitor Output
for X0, X1 (Y4)
Monitor Output
for X0, X1 (Y4)
Safety Output
Safety Output
RUN Monitor
RUN Monitor
Muting Input
Muting Input
Muting Input
Muting Input
Safety Input
Safety Input
Safety Input
Safety Input
(Y17, Y20)
(Y17, Y20)
(Y12,Y13)
(Y12,Y13)
(Y16)
(Y16)
(X16)
(X17)
(X0)
(X1)
(X2)
(X3)
(X0)
(X1)
(X2)
(X3)
Power ON
Power ON
Initializing
Initializing
(Note 4)
Safety
Output ON
6s maximum
(Note 4)
6s maximum
Safety
Output ON
(Safety inputs X4, X5, X10 to X13 are ON, and muting inputs X6 and X7 are off in this chart.)
(Safety inputs X4, X5, X10 to X13 are ON, and muting inputs X6 and X7 are off in this chart.)
(Note 3)
Muting Start
Muting Start
(Note 3)
0.1s minimum
0.1s maximum
0.1s minimum
0.1s maximum
FS1A Safety Controller
Muting End
(Note 3)
Muting End
(Note 3)
Off-delay
Off-delay
(Note 4)
(Note 4)
Time
(Note 3)
Time
(Note 3)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
Muting Start
Muting Start
Safety Output
ON (Note 2)
Safety Output
ON (Note 2)
Muting End
Muting End
0.1s maximum
0.1s minimum
0.1s minimum
0.1s maximum
Note 1: When the muting input is turned on
Note 2: When the muting input is turned on
Note 3: When the input time difference at the
Note 4: When the input time difference at the
Note 1: When the muting input is turned on
Note 2: When the muting input is turned on
Note 3: When the input time difference at the
Note 4: When the input time difference at the
while the safety input is off, muting
function does not become effective
and safety output is not turned on.
while the safety input is on, the muting
fuction becomes effective and the
safety output is turned on when start
input is turned on.
dual channel solid state inputs (X0-X1,
X4-X5) is 0.1s or more, the input
monitor error is detected.
When the input time difference at the
dual channel direct opening inputs
(X10-X11, X12-X13) is 0.5s or more,
the input monitor error is detected.
muting inputs (X2-X3, X6-X7) is 3s or
more, the input monitor error is
detected.
while the safety input is off, muting
function does not become effective
and safety output is not turned on.
while the safety input is on, the muting
fuction becomes effective and the
safety output is turned on when start
input is turned on.
dual channel solid state inputs (X0-X1,
X4-X5) is 0.1s or more, the input
monitor error is detected.
When the input time difference at the
dual channel direct opening inputs
(X10-X11, X12-X13) is 0.5s or more,
the input monitor error is detected.
muting inputs (X2-X3, X6-X7) is 3s or
more, the input monitor error is
detected.
(09/01/07)

Related parts for FS1A-C01S