MPAXP000 Red Lion Controls, MPAXP000 Datasheet
MPAXP000
Specifications of MPAXP000
Related parts for MPAXP000
MPAXP000 Summary of contents
Page 1
... LPAXCK0 0 MPAXCK1 0 †† †† LPAXCK0 0 MPAXTM10 INPUT RANGES * MPAX MODULES 85-250 VAC VDC/ 24 VAC MPAXD000 MPAXD010 MPAXP000 MPAXP010 MPAXT000 MPAXT010 MPAXS000 MPAXS010 MPAXH000 N/A OPTIONAL PLUG-IN CARD COMPATIBILITY SETPOINT COMMS ANALOG YES YES YES YES ...
Page 2
MODEL PAX – 1/8 DIN ANALOG INPUT PANEL METERS LISTED US LISTED R IND. CONT. EQ. 51EB GENERAL DESCRIPTION ® The PAX Analog Panel Meters offer many features and performance capabilities to suit a wide ...
Page 3
ABLE F ONTENTS Ordering Information . . . . . . . . . . . . . . . . . . 2 General Meter Specifications . . . . . . . . . . ...
Page 4
G M ENERAL ETER 1. DISPLAY: 5 digit, 0.56" (14.2 mm) red sunlight readable or standard green LEDs, (-19999 to 99999) 2. POWER: AC Versions: AC Power 250 VAC, 50/60 Hz Isolation: 2300 Vrms for 1 ...
Page 5
M PAXD - U ODEL PAXD SPECIFICATIONS INPUT RANGES: INPUT ACCURACY* ACCURACY* RANGE (18 to 28° 50°C) 0.03% of reading 0.12% of reading 200 ADC +0.03 A +0.04 A 0.03% of reading 0.12% of reading 2 mADC +0.3 ...
Page 6
M PAXH - AC T ODEL PAXH SPECIFICATIONS INPUT RANGES: Isolation To Option Card Commons and User Input Commons: 125 Vrms Isolation To AC Power Terminals: 250 Vrms MAX INPUT IMPEDANCE ACCURACY* CONTINUOUS RANGE (60 Hz) OVERLOAD 0.1% of reading ...
Page 7
M PAXT - T ODEL PAXT SPECIFICATIONS READOUT: Resolution: Variable: 0.1, 0.2, 0. degrees Scale Offset Range: -19,999 to 99,999 display units THERMOCOUPLE INPUTS: Input Impedance: 20 MΩ Lead Resistance Effect: 0.03μV/ohm ...
Page 8
O P PTIONAL LUG WARNING: Disconnect all power to the unit before installing Plug-in cards. Adding Option Cards The PAX and MPAX series meters can be fitted with up to three optional plug- in cards. The details for each plug-in ...
Page 9
I NSTALLING THE Installation The PAX meets NEMA 4X/IP65 requirements when properly installed. The unit is intended to be mounted into an enclosed panel. Prepare the panel cutout to the dimensions shown. Remove the panel latch from the unit. ...
Page 10
PAXP Jumper Selection JUMPER SELECTIONS The indicates factory setting. PAXH Jumper Selection CAUTION: To maintain the electrical safety of the meter, remove unneeded jumpers completely from the meter. Do not move the jumpers to positions other than those specified. Main ...
Page 11
PAXT Jumper Selection Main Circuit Board JUMPER JUMPER LOCATION LOCATION RTD USER INPUT INPUT 3.0 W IRING THE WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter. All conductors should conform to the ...
Page 12
INPUT SIGNAL WIRING PAXD INPUT SIGNAL WIRING Before connecting signal wires, the Input Range Jumper and Excitation Jumper should be verified for proper position. Voltage Signal Current Signal (self powered) (self powered) Terminal 3: +VDC Terminal 4: +ADC Terminal ...
Page 13
PAXH INPUT SIGNAL WIRING Before connecting signal wires, the Signal, Input Range and Couple Jumpers should be verified for proper position. Voltage Signal Current Signal (Amps) CAUTION: 1. Where possible, connect the neutral side of the signal (including current shunts) ...
Page 14
USER INPUT WIRING Before connecting the wires, the User Input Logic Jumper should be verified for proper position. If not using User Inputs, then skip this section. Only the appropriate User Input terminal has to be wired. Sinking Logic ...
Page 15
P ROGRAMMING THE DISPLAY MODE The meter normally operates in the Display Mode. In this mode, the meter displays can be viewed consecutively by pressing the annunciators to the left of the display indicate which display is currently shown; ...
Page 16
MODULE Refer to the appropriate Input Range for the selected meter. Use only one Input Range, then proceed to Display Decimal Point. PAXD INPUT RANGE # RANGE #"$%& SELECTION RESOLUTION " 200uA 0--2 ±200.00 µA -. ...
Page 17
DISPLAY ROUNDING* # #52 " 3 These bottom selections are not available for the PAXT. Rounding selections other than one, cause the Input Display to ‘round’ to the nearest rounding increment selected (ie. rounding of ‘5’ ...
Page 18
DISPLAY VALUE FOR SCALING POINT 2 # ?:+ / 83@@@@ to @@@@@ " 3--. - - Enter the second coordinating Display Value by using the arrow keys. This is 4&C "+,C the same for and scaling styles. (Follow the same ...
Page 19
HOLD DISPLAY # *:#83 The shown display is held but all other meter functions continue as long as activated (maintained action). " ?8F,? HOLD ALL FUNCTIONS # The meter disables processing the input, holds all display *:#83 contents, and locks ...
Page 20
SETPOINT SELECTIONS The following selections are accessible only with the Setpoint plug-in card installed. Refer to the Setpoint Card Bulletin shipped with the Setpoint plug-in card for an explanation of their operation. - ,A:6 Select main or alternate setpoints #83 ...
Page 21
MODULE MAX CAPTURE DELAY TIME* # FA86 -. - 0/J sec. " When the Input Display is above the present MAX value for the entered delay time, the meter will capture that ...
Page 22
MODULE The totalizer accumulates (integrates) the Input Display value using one of two modes. The first is using a time base. This can be used to compute a time- temperature product. The second is through a ...
Page 23
Modules 6, 7, and 8 are accessible only with the appropriate plug-in cards installed. A quick overview of each Module is listed below. Refer to the corresponding plug-in card bulletin for a more detailed explanation of each parameter selection. 5.6 ...
Page 24
MODULE DISPLAY INTENSITY LEVEL # Enter the desired Display Intensity Level (0-15) by ?8,&1 using the arrow keys. The display will actively dim or " 0 brighten as the levels are changed. This parameter also appears ...
Page 25
AC Couple Offset Calibration - PAXH It is recommended that Input Calibration be performed first. 1. With meter power removed, set the Input Range Jumper for 20 V, the Couple Jumper for DC, and set the Signal Jumper for voltage ...
Page 26
TROUBLESHOOTING PROBLEM NO DISPLAY PROGRAM LOCKED-OUT MAX, MIN, TOT LOCKED-OUT INCORRECT INPUT DISPLAY VALUE “OLOL” in DISPLAY (SIGNAL HIGH) “ULUL” in DISPLAY (SIGNAL LOW) JITTERY DISPLAY MODULES or PARAMETERS NOT ACCESSIBLE ERROR CODE (Err 1-4) DISPLAY ZERO’S AT LEVELS BELOW ...
Page 27
User Input and Function Key Parameters DISPLAY PARAMETER USr-1 USER INPUT 1 USr-2 USER INPUT 2 USr-3 USER INPUT 3 F1 FUNCTION KEY 1 F2 FUNCTION KEY 2 rSt RESET KEY Sc-F1 2nd FUNCTION KEY 1 Sc-F2 2nd FUNCTION ...
Page 28
PAX PROGRAMMING QUICK OVERVIEW 27 ...
Page 29
... The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property ...
Page 30
MODEL LPAX- 5 DIGIT LARGE PAX DISPLAY FOR ANALOG INPUTS 4 GENERAL DESCRIPTION The LPAX Display is a versatile display that can increase productivity by offering the plant floor or production area a large visual display of their current status. ...
Page 31
... Installation Category II, Pollution Degree 2. Panel gasket and keps nuts included. 12. WEIGHT: 2.7 lbs (1.2 kg) (less module) INPUT RANGES 85-250 VAC MPAXD000 MPAXP000 MPAXT000 MPAXS000 MPAXH000 LINEAR DC OUTPUT (PAXCDL) Either a 0(4)- 0-10 V retransmitted linear DC output is available from the analog output plug-in card. The programmable output low and high scaling can be based on the input, max, min, or total display value ...
Page 32
ASSEMBLING THE DISPLAY CAUTION: The MPAX main circuit board and the option cards contain static sensitive components. Before handling the module or the cards, discharge static charges from your body by touching a grounded bare metal object. Handle the ...
Page 33
... Analog Output Card Custom Units Label Crimson 2 PC Configuration Software for Windows 98, ME, 2000 and XP NEMA 4 Enclosure for LPAX Shroud for LPAX Mounting Bracket for LPAX PART NUMBERS LPAX0500 MPAXD000 MPAXD010 MPAXP000 MPAXP010 MPAXT000 MPAXT010 MPAXH000 MPAXS000 MPAXS010 PAXCDS10 PAXCDS20 PAXCDS30 ...