CUB5VB00 Red Lion Controls, CUB5VB00 Datasheet - Page 11

Voltage Meter

CUB5VB00

Manufacturer Part Number
CUB5VB00
Description
Voltage Meter
Manufacturer
Red Lion Controls
Type
Voltager
Datasheet

Specifications of CUB5VB00

No. Of Digits / Alpha
5
Meter Function
DC Voltmeter
Meter Range
0mV To 200mV / 0V To 2V / 0V To 20V / 0V To 200V
Digit Height
12.2mm
Operating Temperature Range
-35°C To +75°C
Meter Signal Input
Voltage
Accuracy
±0.1% %
Connection Type
Screw
Cut Out, Panel
2.68×1.3 "
Dimensions
2.95"L×1.86"W×1.54"H
Display Digit Height
0.48 "
Display Type
LCD
Function
Voltage
Material, Casing
Plastic
Number Of Digits
5
Primary Type
Electronic
Range, Measurement
200 mVDC to 200 VDC
Special Features
Communication and Control
Voltage, Supply
9 to 28 VDC
Power Supply
9 to 28 VDC
Dc Current
200 μA to 200 mA
Dc Voltage
200 mV to 200 V
Process Signals
0(4) to 20 mA or 0 - 10 VDC
Display Mode
Selectable Transmissive
Rohs Compliant
Yes
Backlighting Color
Red Or Green
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
L-dLY
6.5 MODULE 5 - S
OUTPUT
button or user input manual reset, serial reset command or meter power
cycle. When the user input or
the corresponding “on” output is reset immediately and remains off until the
trigger point is crossed again. (Previously latched alarms will be off if power
up Display Value is lower than setpoint value.)
trigger point per the Setpoint Action shown in Setpoint Output Figures. Latch
means that the output can only be turned off by the front panel
or user input manual reset, serial reset command or meter power cycle. When
the user input or
delays the event until the corresponding “on” output crosses the trigger off
point. (Previously latched outputs are off if power up Display Value is lower
than setpoint value. During a power cycle, the meter erases a previous
reset if it is not activated at power up.)
The Serial Setup Parameters are only active when one of the optional serial communication/programming cards is installed in the meter.
Refer to the CUB5COM bulletin for details on CUB5 RS232 or RS485 serial communications.
Refer to the CUB5USB bulletin for details on the CUB5 USB programming and programming requirements.
STATE
SP - Hys
= Latch with delay reset action; This action latches the output on at the
SEL
5-SEr
bAUd
Baud Rate
{
SP
OFF
OFF
OFF
Setpoint Output Reset Actions
RST
ON
The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years
from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The
Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The
Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses
arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal
injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to
any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-573) and liability
imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein.
The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.
button is activated (momentary action), the meter
ON
ON
dAtA
RST
Data Bit
OFF
button is activated (momentary action),
OFF
OFF
ON
ON
MANUAL
RESET
ON
ERIAL
PAr
Parity Bit
OFF
OFF
OFF
PARAMETER MENU
RST
(
(
(
S
Auto
LIMITED WARRANTY
LAtCH
L-dLY
ETUP
button
)
L-dLY
)
)
Hys
Addr
11
Address
P
Meter
the display is reset.
must be set to
not met, the output will not reset.
crossed. Once the output is on, the output operates normally per the Setpoint
Action and Output Reset Action.
the output state changes. This parameter is only active for the backlight version.
ChC-n
rEn-n
Stb-n
ARAMETERS
This parameter enables the
Note: For this parameter to operate, the
When
This parameter enables the backlight CUB5 to switch the backlight color when
CHANGE DISPLAY COLOR w/OUTPUT STATE
YES
YES
, the output is disabled (after a power up) until the trigger point is
OUTPUT RESET WITH DISPLAY RESET
NO
NO
dSP
and the Input value must be displayed. If these conditions are
Abbr
Abbreviated
Printing
STANDBY OPERATION
(
RST
NO
5-SEr
NO
NO
button or user input to reset the output when
)
RST
OPt
YES
Options
button or User Input being used
Print
YES
YES
Pro

Related parts for CUB5VB00