6-Y-1-2-RMF-PM-115A EATON CUTLER HAMMER, 6-Y-1-2-RMF-PM-115A Datasheet - Page 51

Electromechanical Totalizing Counter

6-Y-1-2-RMF-PM-115A

Manufacturer Part Number
6-Y-1-2-RMF-PM-115A
Description
Electromechanical Totalizing Counter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of 6-Y-1-2-RMF-PM-115A

No. Of Digits / Alpha
6
Digit Height
4.8mm
Power Consumption
7W
Mounting Type
Panel
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Counter Supply Voltage
115VAC
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eclipse Series—Durant
Product Description
High visibility LED readout
with a variety of output
options.
Product Selection
Eclipse Series
Technical Data and Specifications
General Specifications
Description
Mechanical
Cutout dimensions
Outline dimensions
Enclosure
Connectors
Environmental
Operating environment
Temperature
Humidity
Vibration
Shock
EMC
Front panel
CE EMC
Pollution degree 2
Input Power
AC powered models (57701-4XX)
DC powered models (57700-4XX)
Operating
Storage
Input power
External fuse
Isolation dielectric strength
Input power
External fuse
Reverse voltage protection
Isolation dielectric strength
Eclipse Series Totalizer, Six-Digit LED
Description
9–30 Vdc power
85–265 Vac power
Analog out, 9–30 Vdc power
Analog out, 85–265 Vac power
RS-485 out, 9–30 Vdc power
RS-485 out, 85–265 Vac power
RS-485 out and analog out, 9–30 Vdc power
RS-485 out and analog out, 85–265 Vac power
Specification
3.62 in W x 1.77 in H (92 mm x 45 mm) DIN standard
4.04 in W x 2.19 in H x 3.87 in D (103 mm x 56 mm x 98 mm) 3.60 in (92 mm) maximum depth in panel
Plastic with polyester front label
Up to six depluggable terminal blocks
Indoor use to 2000 meters
32 to 122°F (0 to 50°C)
–4 to 158°F (–20 to 70°C)
0 to 85% RH, non-condensing
2.5 Gs, 30 to 200 Hz
30 Gs, 11 ms half sinewave
Immunity to EN 50082-2 (heavy industrial)
Emissions to EN 50081-2 (heavy industrial)
NEMA 4X when mounted with gasket provided
Immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and
pulse input/ power lines. The shields were connected to earth ground at the Eclipse end of the shields.
Overvoltage category II
85–295 Vac, 47–63 Hz, 20 VA
0.2A, 250 Vac, time delay (T200 mA, 250V)
2300 Vac
9–30 Vdc, 12 VA
2.0A, 50 Vdc, time delay (T2A, 50V)
Yes
2300 Vac to signal outputs and relays, 500 Vac to RS-485 and analog outputs
®
Counters, Panel Meters, Tachometers and Timers
Features
1/8 DIN cutout
NEMA 4X front panel
Universal AC power supply
(85–265 Vac)
DC power models
(9–30 Vdc)
Control Products Catalog CA08102001E—August 2010 www.eaton.com
Removable screw
terminals
Short depth: 3.6 in
(91 mm)
Front panel programming
Catalog Number
57700480
57701480
57700482
57701482
57700484
57701484
57700486
57701486
Totalizers
Standards and Certifications
UL and cUL listed
CE marked
54.1
51
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54

Related parts for 6-Y-1-2-RMF-PM-115A