SQC1200U VEEDER ROOT, SQC1200U Datasheet - Page 142

Multifunction Counter

SQC1200U

Manufacturer Part Number
SQC1200U
Description
Multifunction Counter
Manufacturer
VEEDER ROOT
Type
Counter/Totalizerr
Datasheets

Specifications of SQC1200U

No. Of Digits / Alpha
6
Digit Height
4mm
Power Consumption
6VA
Counting Speed
2.4kHz
Operating Temperature Range
0°C To +50°C
Signal Input Type
Contact Closure, Pulse
Character Size
7mm
Brand/series
Squire
Counter Type
Dual Preset
Cut Out, Panel
1/16 DIN
Display Type
Transflective LCD, LED Backlight
Function
Counter/Totalizer
Voltage, Supply
85 to 260 VAC
Lead Free Status / RoHS Status
na
R
O
N
E
L
E
C
T
C
I
5
M
R
S
T
E
M
I
T
E
R
S
I
OPERATION
The timing is controlled by an internal oscillator. The oscillator output is
directed to designated frequency dividers through a programming wire,
providing the selection of one of three time ranges.
Relay (CR1) is energized when power is applied to the control input. For
standard start units, timing starts when the clutch relay is energized. For
reverse start units, the timer is reset when the clutch relay is energized and
timing starts when the input to the relay is removed.
A delay relay (CR2) is energized when the timing cycle is complete. The
operation of the delay relay is identical in both standard start and reverse
start units.
5.48
The CD300 is a solid state reset timer housed in a standard CYCL-
FLEX
function. The timer is set by three digital thumbwheel switches on the
front of the unit. Five neon annunciators on the front of the unit indicate
when the unit is timing, and the timing cycle progress in increments of
25%, 50%, 75%, and 100% (timed out).
Configured into one of three time ranges via program wire located
on printed circuit board inside the unit (easily accessible when unit is
removed from the case)
Function is similar to Eagle Signal brand HP5 and CT530/531
Easily programmable reverse start feature
Two electromechanical relays control output sequences - one
energizes when timer starts timing cycle and the other energizes
when timer completes timing cycle
Usable timing output available when instantaneous and delayed
relay contacts are interconnected
EAGLE SIGNAL
Electronic Timers
®
case. The timer uses CMOS integrated circuits for the timing
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
brand
SPECIFICATIONS
Time Ranges:
Operating Voltage/Frequency: 120 VAC, 50/60 Hz
Repeatability (Constant Voltage & Temperature):
Repeatability (Voltage & Temperature Variation):
Reset Time: 100 ms
Cycle Progress: Cycle ON annunciator with time progression annunciators
Burden:
Power on Response: 40 ms max. after application of line voltage to pins 1
Operating Temperature: +0° to 60°C (+32° to +140°F)
Output Rating: Relay: 10 amp steady state at 120 VAC, 60 Hz
Power Interruption:
Transient Voltage Immunity: Unaffected by 50 microseconds, 600 V peak
Vibration: Unit function is unaffected by 2.5
Approvals: UL Recognition E96337
The 01 time range is standard. The CD is field programmable for the
other time ranges.
240 VAC, 50/60 Hz
Variable Voltage:
Variable Temperature:
Variable Voltage and Temperature:
indicating elapsed time percentages of 25%, 50%, 75%, and 100% (cycle
complete)
120 VAC
240 VAC
and 2
Mechanical Life: over 20 million operations
Electrical Life: contingent on load characteristics
Line voltage interruptions of 16 ms or less will not reset unit
transients superimposed on the line input
tude in both directions of three perpendicular mounting axes imposed
from 10 to 100 Hz
CSA Certification LR26861
0.1% of setting or 35 ms, whichever is larger
CD300 Solid State
Solid state reset
timer... housed in
standard CYCL-FLEX
case
Reset
.8 VA max.
1.6 VA max.
Sym.
01
02
03
1% of setting or 35 ms
2% of setting or 35 ms
Maximum
99.9 Sec.
99.9 Min.
999 Sec.
Range
Timing
4.0 VA max.
4.8 VA max.
3% or 35 ms
G
sinusoidal vibration magni-
Minimum
Setting
.1 Sec.
1 Sec.
.1 Min.
®
RECOGNIZED
®
Timed-Out
7.3 VA max.
8.0 VA max.
CERTIFIED
®

Related parts for SQC1200U