SQC1200U VEEDER ROOT, SQC1200U Datasheet - Page 136

Multifunction Counter

SQC1200U

Manufacturer Part Number
SQC1200U
Description
Multifunction Counter
Manufacturer
VEEDER ROOT
Type
Counter/Totalizerr
Datasheets

Specifications of SQC1200U

No. Of Digits / Alpha
6
Digit Height
4mm
Power Consumption
6VA
Counting Speed
2.4kHz
Operating Temperature Range
0°C To +50°C
Signal Input Type
Contact Closure, Pulse
Character Size
7mm
Brand/series
Squire
Counter Type
Dual Preset
Cut Out, Panel
1/16 DIN
Display Type
Transflective LCD, LED Backlight
Function
Counter/Totalizer
Voltage, Supply
85 to 260 VAC
Lead Free Status / RoHS Status
na
R
O
N
E
L
E
C
T
C
I
5
M
R
S
T
E
M
I
T
E
R
S
I
SPECIFICATIONS
Time Ranges:
Operating Voltage/Frequency: A6 - 120 VAC, 50/60 Hz
Setting Accuracy:
5.42
The DG200 series timer is a microprocessor based, four digit reset
timer housed in a 1/8 DIN style enclosure. Four push-button switches
on the front of the unit provide exact setting of the time setpoint. There
are four time ranges from 99.99 seconds to 99 hours and 99 minutes.
There are two versions of this timer series. The DG201 has six basic
output operating modes. The DG203 has the six output modes of the
DG201, but it also has a control input for Delay-On-Release and Single-
Shot operation. In the other modes, the DG200 control input can be
used for a time inhibit function which stops the timing cycle without
resetting the unit. Rocker switches, located on the side of the unit, are
used to program the time ranges and operating modes.
The DG200 timer can be mounted in three ways for use in most any
application. The terminal connections for the unit are 3/16 inch
terminals for use with a square base relay socket. This provides a
means of mounting the unit within a panel. The DG200 timer can also
be mounted through the front of the panel using either an economical
fixed bezel kit or a unique plug-in housing which allows easy removal
for programming changes and replacement.
Other features include:
The control input on the DG203 also operates at this voltage.
5 amp SPDT relay output
Separate LED indicators to show timing and relay output operation
Recessed programming rocker switches with a protective cover to
help prevent accidental switch changes
0.01 second setting resolution for fast time cycles and easy to use
minute: second and hour: minute time ranges
Optically isolated control input on the DG203 version
Time inhibit function on the DG203 version
EAGLE SIGNAL
Electronic Timers
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
Sym.
0.01% of setting or 35 ms, whichever is larger
1
2
3
4
99 Min.: 99 Sec.
99 Hr.: 99 Min.
Maximum
99.99 Sec.
999.9 Sec.
Range
Minimum
Setting
.01 Sec.
brand
.1 Sec.
1 Sec.
1 Min.
DG200 MINIFLEX
Repeat Accuracy:
Reset Time: 35 ms
Power on Response: 35 ms
Operating Temperature: +32° to +122°F (0° to +50°C)
Output Rating: 5 amp, 10 to 240 VAC resistive
Vibration: Unit function is unaffected by 2.5
Static Discharge: Unit function is unaffected by a constant 3600 volt peak,
Transient Protection: Immune to 2500 volts peak transients up to 50
OUTPUT OPERATING MODES
ON-Delay Operation
Interval Operation
Timed Pulse Output Operation
PROGRAMMED
PROGRAMMED
PROGRAMMED
in both directions of the perpendicular mounting axes imposed from 20 to
100 Hz
60 Hz discharge applied to the front plate at a relative humidity of less
than 25%
microseconds in duration
The output contacts are energized at the end of the timing cycle and
remain energized until the unit is reset.
The output contacts are energized during the timing cycle and
deenergized at the end of the cycle.
The output contacts are energized at the end of the timing cycle for a 100
millisecond pulse output.
START INPUT
START INPUT
CONTACTS
START INPUT
CONTACTS
CONTACTS
1/8 DIN sized plug-in
timer with digital
setpoint... 8 operating
modes accommodate all
popular timer
configurations
TIMING
0.01% of setting or 35 ms, whichever is larger
®
TIMING
TIMING
Digital Set Reset Timer
PULSE
RESET
RESET
RESET
RESET
G
sinusoidal vibration magnitude

Related parts for SQC1200U