Y92A-48F1 Omron, Y92A-48F1 Datasheet - Page 28

Soft Cover

Y92A-48F1

Manufacturer Part Number
Y92A-48F1
Description
Soft Cover
Manufacturer
Omron
Datasheets

Specifications of Y92A-48F1

Accessory Type
Soft Cover
For Use With
Digital Counter H7CZ Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H5CX-B
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92A48F1
Z2802
Explanation of Functions
OFF Time Range (oftr) (Setting possible using DIP
switch.)
Set the time range for the OFF time in the range 0.000 s to 9,999 h.
Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s),
and -- min -- s (99 min 59 s), however, can be made with the DIP
switch. Use the operation keys if another type of setting is required.
ON Time Range (ontr) (Setting possible using DIP
switch.)
Set the time range for the ON time in the range 0.001 s to 9,999 h.
Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s),
and -- min -- s (99 min 59 s), however, can be made with the DIP
switch. Use the operation keys if another type of setting is required.
Timer Mode (timm) (Setting possible using DIP switch.)
Set either UP (incremental) or DOWN (decremental) timer mode. In
UP mode, the elapsed time is displayed, and in DOWN mode, the
remaining time is displayed.
ON/OFF Start Mode (totm) (Setting possible using DIP
switch.)
Set the output mode. Set either flicker OFF start or flicker ON start.
(For details on output mode operation, refer to Timing Charts on
page 30.)
Key Protect Level (kypt)
Set the key protect level.
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON.
Note: Changing mode to timer/twin timer selection mode (
KP-1
(default setting)
KP-2
KP-3
KP-4
KP-5
Note: Factory-set to OFF
(See note)
Level
OFF
ON
Key protect indicator
Meaning
No
No
No
No
No
Changing mode
(See note.)
MODE
+
1
Yes
Yes
Yes
Yes
No
1 s min.) or function setting mode (
Switching display
during operation
Input Signal Width (iflt) (Setting possible using DIP
switch.)
Set the minimum signal input width (20 ms or 1 ms) for signal, reset,
and gate inputs. The same setting is used for all external inputs (sig-
nal, reset, and gate inputs). If contacts are used for the input signal,
set the input signal width to 20 ms. Processing to eliminate chatter-
ing is performed for this setting.
NPN/PNP Input Mode (imod)
Select either NPN input (no-voltage input) or PNP input (voltage
input) as the input format. The same setting is used for all external
inputs. For details on input connections, refer to Input Connections
on page 9.
Display Color (colr)
Set the color used for the present value.
red
grn
r-g
g-r
Red (fixed)
Green (fixed)
Red
Green
Details
Output OFF
Yes
No
Yes
No
No
Reset key
MODE
3 s min.).
Green
Red
Yes
Yes
No
No
No
H5CX-A/-L
Output ON
Up/down key
28