Description
H2C TIME SETTING RING
Manufacturer
Omron
Datasheet

Specifications of Y92A-Y1

Accessory Type
Ring - Time Setting
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H2C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92AY1
DIN-sized 48 x 48 Motor Timer with Simple
Operation for Switching Time Specifications
• Three Motor Timers cover the wide time range of 6 s to 30 h with
• Five time specifications for each model with linked time display.
• DIN-standard size of 48 x 48 mm.
• Easily check operation with neon lamp.
• Models with sockets and models with top wiring are also avail-
• Certified for UL and CSA safety standards.
• Conforms to EN 61812-1 (except models that end with “-F”) and
Model Number Structure
■ Model Number Legend
1. External Connection/Attachment
Ordering Information
■ List of Models
H2C-@ @
Note: Specify both the supply voltage and time range code (A, B, or C) in addition to the model number when ordering.
Time-limit operation/
self-resetting
Time-limit operation/
electric resetting
easy operation from the operation panel.
able.
CE Marking.
Operation/resetting
Motor Timer
H2C
None: 11-pin socket
S:
8:
F:
Example: H2C-S 24 VAC B
system
1
11-pin socket/time setting ring
8-pin socket
Front screw
2
Parallel motor and
clutch connection
Separate motor
and clutch
connection
connection
Internal
Time range code
Supply voltage
8-pin socket
11-pin socket
Front screw
8-pin socket
11-pin socket
Front screw
Terminal
SPDT
SPDT
Time-limit
contact
2. Operation/Resetting System
None: Time-limit operation/self-resetting
R:
SPDT
---
SPDT
Instantaneous
Time-limit operation/electric resetting
contact
---
Y92A-Y1 Time
Setting Ring
---
---
Y92A-Y1 Time
Setting Ring
---
Attachment
H2C-8
H2C
H2C-S
H2C-F
H2C-8R
H2C-R
H2C-SR
H2C-FR
CSM_H2C_DS_E_2_1
Model
1

Related parts for Y92A-Y1

Y92A-Y1 Summary of contents

Page 1

... Time-limit operation/electric resetting Terminal Time-limit Instantaneous contact contact 8-pin socket SPDT SPDT 11-pin socket Front screw 8-pin socket SPDT --- 11-pin socket SPDT Front screw CSM_H2C_DS_E_2_1 Attachment Model --- H2C-8 H2C Y92A-Y1 Time H2C-S Setting Ring --- H2C-F --- H2C-8R H2C-R Y92A-Y1 Time H2C-SR Setting Ring --- H2C-FR 1 ...

Page 2

... Flush mounting (except for H2C-F/-FR models), surface mounting, DIN track mounting Note: The front panel of the timer is color coded to identify the following supply voltage classifications: 100 to 120 V: Blue 200 to 240 V: Red Other classes: Black Y92F-30 Y92A-Y1 PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S ...

Page 3

Characteristics ±0.5% FS max. 〈±1% max for the time range code 0 for the time range Accuracy of operating time code C) ±2% FS max. Setting error Reset ...

Page 4

Connections ■ Terminal Arrangement Note: The connections diagrams are for when the clutch is in the excited, reset state. H2C-8 H2C(-F)/H2C-S Clutch coil 6 (B2) (B1 (B2) (16) (22) (B1) 8 (16) (18) 4 (24) (22) (18) (A1) ...

Page 5

Operation ■ Timing Chart H2C Power (2-7) Time-limit contacts NC (8-5) Time-limit contacts NO (8-6) Instantaneous contacts NC (1-4) Instantaneous contacts NO (1-3) Timing operation indicator lamp (OFF at time-up) H2C(-F)/H2C Power and motor 2(A1)-10(A2) Power ...

Page 6

... P3G-08/P3GA-11 81.5 16.3 80 H2C-8 H2C H2C-S H2C-8R H2C-R H2C-SR + Adapter P3GA-11 Y92F-30 (When Y92A-48G P2CF-08 mounted) H2C For Flush Mounting +0.6 45 −0 +0.6 45 −0 Mounting Holes Two 4.5 dia. holes 92.2 16.3 85.7 H2C-8 H2C-8R + Adapter P3G-08 Y92F-30 (When Y92A-48G mounted) 6 ...

Page 7

Accessories (Order Separately) Adapter for Flush Mounting Y92F-30 Track Mounting/Front Connecting Socket P2CF-08 Eight, M3.5 x 7.5 sems 70 max max. P2CF-08-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eight, M3.5 x 7.5 sems 70 max. 4 ...

Page 8

... M3.5 x 7.5 sems 70 max. 4 40±0.2 50 max. Back Connecting Socket P3G-08 27 dia P3GA-11 27 dia Finger Safe Terminal Cover Conforming to VDE0106/P100 Y92A-48G (Attachment for P3G-08/ P3GA-11 Socket) 3 4.5 7.8 Terminal Arrangement/ 35.4 Internal Connections (Top View) Two, 4.5 dia. holes 31.2 max. 7 ...

Page 9

... PFP pan head screw Time Setting Ring Y92A-Y1 The time setting ring locks the time setting knob to store the set time to facilitate its resetting. A maximum of two time setting rings are connectable per timer. Timer Hold-down Clips Y92H-1 Y92H-2 (for PL08/PL11 ...

Page 10

Safety Precautions Refer to Safety Precautions for All Timers. !CAUTION This may occasionally cause electric shock, fire, or malfunction. Never disassemble, repair, or modify the H2C. This may occasionally cause electric shock, fire, or malfunction. Do not allow metal fragments ...

Page 11

Others Do not turn the operation time setting knob beyond the range of the scale. To achieve higher accuracy in setting, measure the operation time while turning the operation time setting knob. The deviation and setting error for the operation ...

Page 12

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords