XTAE007B10TD3E008 EATON CUTLER HAMMER, XTAE007B10TD3E008 Datasheet - Page 196

IEC Non-Reversing Starter

XTAE007B10TD3E008

Manufacturer Part Number
XTAE007B10TD3E008
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTAE007B10TD3E008

No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
8A
Overload Adjustment Current Min
1.6A
Supply Voltage Max
24VDC
Frame Size
Standard
27.1
Features
V5-T27-196
ON/OFF rotary handle
with lockout provision
Visible trip indication
Test trip function
Motor applications
from 0.10A to 65A
Class 10 overload
protection
Built-in heater and
magnetic trip elements
to protect the motor
Phase loss sensitivity
Type 2 coordination
Ambient compensated
up to 55°C [140°F]
Control inputs located at
front of starter for easy
access and wiring
Wide range of coils
DIN rail mount—
XTSC…BB_
Mounting plates—
XTSC…BC_, XTSC…D
motor controllers
Adjustment dial for setting
motor FLA
Short-circuit trip at
14 times the maximum
setting of the FLA
adjustment dial
UL 508 Type F CMC high
fault short-circuit ratings
1NO-1NC auxiliary contact
as standard on manual
motor controller and
combination motor
controller
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
IEC Contactors and Starters
XT IEC Power Control
Standards and Certifications
UL 508 Type F combination
motor controller
Note: For Type 2 Coordination of
MMCs, see Page V5-T27-219.
Protection in different controller
types
IEC Type 2 Approved per
IEC 60947-4-1
UL Listed File No. E245398
CE Mark
MMC and CMC Applications
Notes
Technical Paper AP03402001E.
Line side adapters are not required for non-U.S. applications.
Most countries outside of the U.S. classify the MMP as a
motor-protective circuit breaker.
XTSC/XTSR
Use in group installation
applications. Upstream
SCPD
be sized smaller than the
maximum upstream SCPD
rating on each MMC
Tap rules should also be
Not required
observed.
SCPD = Short-circuit protective device (circuit breaker, fuses).
MMC = Manual motor controller
Manual Motor Controller
Manual Motor Controller
Line Side Adapter (LSA)
is required and must
XTIEC Manual and Combination Motor Controllers
used.
Use for single motor branch circuits or use
multiple CMC’s for a multiple motor panel
applications. No additional SCPD
in the branch, as these devices are “self-
protected”.
Combination Motor Controller
XTFC/XTFR
Required—factory assembled
UL 508 Type F Combination
Line Side Adapter (LSA)
Motor Controller
is required