XTAE007B10TD2P4 EATON CUTLER HAMMER, XTAE007B10TD2P4 Datasheet - Page 212

IEC Non-Reversing Starter

XTAE007B10TD2P4

Manufacturer Part Number
XTAE007B10TD2P4
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTAE007B10TD2P4

No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
2.4A
Overload Adjustment Current Min
1.6A
Supply Voltage Max
24VDC
Frame Size
Standard
27.1
Combination Motor Controllers Short-circuit Ratings for UL 508 Type F Application
XTFC and XTFR Combination Motor Controllers (CMC), UL 508 Type F
Assembled Controller
Non-Reversing
XTFC and XTFR Frame B MMP + Frame B Contactor
XTFCP16BB_
XTFCP25BB_
XTFCP40BB_
XTFCP63BB_
XTFC001BB_
XTFC1P6BB_
XTFC2P5BB_
XTFC004BB_
XTFC6P3BB_
XTFC010BB_
XTFC012BB_
XTFC016BB_
XTFC and XTFR Frame B MMP + Frame C Contactor
XTFC016BC_
XTFC020BC_
XTFC025BC_
XTFC032BC_
XTFC and XTFR Frame D MMP + Frame C Contactor
XTFC016DC_
XTFC025DC_
XTFC032DC_
XTFC and XTFR Frame D MMP + Frame D Contactor
XTFC040DD_
XTFC050DD_
XTFC058DD_
XTFC063DD_
Notes
V5-T27-212
Underscore (_) indicates magnetic coil suffix required. See Page V5-T27-204.
For UL 508 Type F applications, the combination motor controller assembly does not require a dedicated upstream protective device in the panel, thus a maximum rating is not required.
Reversing
XTFRP16BB_
XTFRP25BB_
XTFRP40BB_
XTFRP63BB_
XTFR001BB_
XTFR1P6BB_
XTFR2P5BB_
XTFR004BB_
XTFR6P3BB_
XTFR010BB_
XTFR012BB_
XTFR016BC_
XTFR020BC_
XTFR025BC_
XTFR032BC_
XTFR016DC_
XTFR025DC_
XTFR032DC_
XTFR040DD_
XTFR050DD_
XTFR058DD_
XTFR063DD_
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
IEC Contactors and Starters
XT IEC Power Control
FLA Adjustment
Range/Overload
Release—
I
0.1–0.16
0.16–0.25
0.25–0.4
0.4–0.63
0.63–1
1–1.6
1.6–2.5
2.5–4
4–6.3
6.3–10
8–12
10–16
10–16
16–20
20–25
25–32
10–16
16–25
25–32
32–40
40–50
50–58
55–65
r
(Amps)
Short-Circuit
Release—
I
2.2
3.5
5.6
8.82
14
22.4
35
56
88.2
140
168
224
224
280
350
448
224
350
448
560
700
812
882
rm
(Amps)
UL 508 Type F Application
Max. rms Symmetrical Short-Circuit
Ratings (kA)
240V
65
65
65
65
65
65
65
65
65
65
65
50
18
18
18
18
50
50
65
65
65
65
65
480/277V
65
65
65
65
65
65
65
65
65
65
65
50
18
18
18
18
50
50
65
65
65
65
65
600/347V
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
Maximum Upstream
Protective Device (A)
Maximum Fuse
600V
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Maximum Circuit
Breaker 600V
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required
Not required

Related parts for XTAE007B10TD2P4