XTAE007B10TD2P4 EATON CUTLER HAMMER, XTAE007B10TD2P4 Datasheet - Page 179

IEC Non-Reversing Starter

XTAE007B10TD2P4

Manufacturer Part Number
XTAE007B10TD2P4
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTAE007B10TD2P4

No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
2.4A
Overload Adjustment Current Min
1.6A
Supply Voltage Max
24VDC
Frame Size
Standard
XT Manual Motor Protectors, continued
Description
Releases
Overload release setting range (x I
Fixed short-circuit release (x I
Short-circuit release tolerance
Phase-failure sensitivity
Temperature compensation
Temperature compensation residual error for T >20°C, %/K
Auxiliary Contacts
Description
Rated impulse withstand voltage, U
Overvoltage category/pollution degree
Rated operational voltage
Safe isolation to VDE 0106 Part 101 and
Part 101/A1 between auxiliary contacts
and main contacts (Vac)
Rated operational current
AC-15
220–240 V, I
380–415 V, I
440–500 V, I
DC-13 L/R <100 ms
24 V, I
60 V, I
110 V, I
220 V, I
Lifespan
Mechanical, operations (x 10
Electrical, operations (x 10
Contact reliability (at U
I
Positively driven contacts to ZH 1/457
Short-Circuit Rating without Welding
Fuseless
Fuse (A gG/gL)
Terminal Capacity
Solid or flexible conductor with ferrule (mm
Solid or stranded (AWG)
min
to IEC/EN 60947, VDE 0660, °C
operating range, °C
U
U
e
e
(Vac)
(Vdc)
= 5.4 mA, fault probability
e
e
e
e
(A)
(A)
(A)
(A)
e
e
e
(A)
(A)
(A)
e
= 24 Vdc, U
6
)
6
u
)
)
u
)
imp
min
–17V,
(Vac)
2
)
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
XTPBP16B–
XTPB025B
0.6–1.0
14
± 20%
IEC/EN 60947-1-1,
VDE 0660 Part 102
–5/40
–25/55
XTPAXSA_ _
6000
III/3
500
250
690
3.5
2
1
2
1.5
1
0.25
0.1
0.05
<10
at 1 x 10
Yes
FAZ-B4/1-HI
10
0.75–2.5
18–14
0.25
–8
<1 fault
8
operations
IEC Contactors and Starters
XTPAXFA_ _
4000
III/3
440
250
690
1
2
0.1
0.1
<10
at 1 x 10
10
0.75–1.5
18–16
–8
<1 fault
8
operations
XTPRP16B–
XTPR032B
0.6–1.0
14
± 20%
IEC/EN 60947-1-1,
VDE 0660 Part 102
–5/40
–25/55
0.25
XTPA(B)XFAEM_ _
4000
III/3
440
250
690
1
2
0.1
0.1
<10
at 1 x 10
10
0.75–1.5
18–16
XT IEC Power Control
–8
<1 fault
8
operations
XTPR016D–
XTPR063D
0.6–1.0
14
± 20%
IEC/EN 60947-1-1,
VDE 0660 Part 102
–5/40
–25/55
XTPAXSATR_ _
6000
III/3
500
250
690
3.5
2
1
2
1.5
1
0.25
0.01
0.005
<10
at 1 x 10
FAZ-B4/1-HI
10
0.75–2.5
18–14
0.25
–8
<1 fault
8
27.1
operations
V5-T27-179