HFE1 FAIRFORD ELECTRONICS, HFE1 Datasheet - Page 4

no-image

HFE1

Manufacturer Part Number
HFE1
Description
SOFTSTARTER, HFE1, 10A
Manufacturer
FAIRFORD ELECTRONICS
Datasheet

Specifications of HFE1

No. Of Phases
Single
Current Rating
10A
Approval Bodies
IEC 60947-4-2
External Depth
68mm
External Length / Height
218mm
External Width
64mm
Ip/nema
RoHS Compliant
For Use With
10A MCB Trip Characteristic Type "C"

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HFE10-2/12-HT-L2
Manufacturer:
HONGFA
Quantity:
20 000
Part Number:
HFE1600-12
Quantity:
133
Part Number:
HFE1600-12/S
Manufacturer:
TDK-LAMBDA
Quantity:
165
Part Number:
HFE1600-12/S
Quantity:
137
Part Number:
HFE1600-24
Quantity:
134
Part Number:
HFE1600-24/S
Manufacturer:
TDK-LAMBDA
Quantity:
165
Part Number:
HFE1600-24/S
Quantity:
138
Part Number:
HFE1600-32
Quantity:
135
Part Number:
HFE1600-32/S
Manufacturer:
TDK-LAMBDA
Quantity:
165
Part Number:
HFE1600-48/S
Manufacturer:
TDK-LAMBDA
Quantity:
165
Part Number:
HFE1600-D1U
Manufacturer:
TDK-LAMBDA
Quantity:
165
STARTING
Amps
Rating Table
* 13A fused plug may be used but not for more than load amps 5A at duties as
indicated in Rating Table
Load
SPECIFICATIONS
Pedestal Voltage
Start Time:
Terminations:
Ambient Temperature:
Enclosure:
Rated Operational Voltage:
Recommended cut–out device:
Rated insulation voltage:
Rated impulse withstand voltage:
Short circuit co–ordination:
Fuse Type:
Design standards: IEC 60947–4–2: “AC Semiconductor Motor Controllers and Starters”.
Document No. FD194509-F
(Ie)
operational
10
The rated
5
Fairford Electronics Limited, Coombe Works, Derby Road, Kingsbridge, Devon TQ7 1JL, UK
current
Utilisation
Category
AC53a
AC53a
Continuous
connection
10A
TEL: + 44 (0) 1548 857494
EMAIL: sales@fairford.co.uk
Current
(Amps)
10
15
30
40
:
Start
AC–53a : 4 – 3 : 99 – 10
Allowed start
current (X Ie)
(Secs)
page 4 M-1945-F 100226
Time
3
2
4
3
Fixed at ~15%.
Continuously variable from ½S -5S.
Cage clamp terminals suitable for 0.75mm
0°C to 40°C without derating.
IP20 with standard cover:
Ue: 110 to 230V ac (–15% +10%), 50/60Hz
10A rated MCB, Trip Characteristic “C“.
Ui: 250V.
Uimp: 4kV (1.2/50µs).
Type 1 , Iq: 5kA when protected by recommended Fuse
See rating table.
to 2.5mm
Duty
99%
99%
99%
99%
2
Allowed start
(12 awg)Solid or stranded
FAX: + 44 (0) 1548 853118
time (S)
WEB: www.fairford.co.uk
Starts/Hr
Up to
60
60
60
10
© Fairford Electronics Ltd 2010
class gR/aR
*22x58mm
Max fuse
time on
load (%)
rating
20A
32A
Trip Characteristic
Equally spaced
2
Cut-out device
(18 awg)
starts/Hr
10A MCB
Type "C"

Related parts for HFE1