HFE1 FAIRFORD ELECTRONICS, HFE1 Datasheet - Page 3

no-image

HFE1

Manufacturer Part Number
HFE1
Description
SOFTSTARTER, HFE1, 10A
Manufacturer
FAIRFORD ELECTRONICS
Datasheet

Specifications of HFE1

No. Of Phases
Single
Current Rating
10A
Approval Bodies
IEC 60947-4-2
External Depth
68mm
External Length / Height
218mm
External Width
64mm
Ip/nema
RoHS Compliant
For Use With
10A MCB Trip Characteristic Type "C"

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HFE10-2/12-HT-L2
Manufacturer:
HONGFA
Quantity:
20 000
Part Number:
HFE1600-12
Quantity:
133
Part Number:
HFE1600-12/S
Manufacturer:
TDK-LAMBDA
Quantity:
165
Part Number:
HFE1600-12/S
Quantity:
137
Part Number:
HFE1600-24
Quantity:
134
Part Number:
HFE1600-24/S
Manufacturer:
TDK-LAMBDA
Quantity:
165
Part Number:
HFE1600-24/S
Quantity:
138
Part Number:
HFE1600-32
Quantity:
135
Part Number:
HFE1600-32/S
Manufacturer:
TDK-LAMBDA
Quantity:
165
Part Number:
HFE1600-48/S
Manufacturer:
TDK-LAMBDA
Quantity:
165
Part Number:
HFE1600-D1U
Manufacturer:
TDK-LAMBDA
Quantity:
165
WIRING
The soft starter is normally inserted into the circuit between the motor and whatever switchgear
is normally used for isolation or switching. The unit can also be fitted before switchgear so that
it can be installed in the supply to equipment which has it’s own mechanical control.
This feature allows for easy installation on equipment such as refrigeration where the need to
disturb internal wiring is avoided.
The terminations are made with industry standard cage clamp screw terminals directly onto the
circuit board on all units.
The incoming power supply is connected to the terminals marked ‘L’ and ‘N’. For EMC compli-
ance it is important that the line circuit is connected to L and the neutral circuit to N. Outgoing
connections from the HFE are taken from the terminals marked ‘L
load input terminals (see diagram). Ensure that a good connection is made to the earth
terminals provided.
Fuses or other type of short-circuit protection are required for protection against a cable or
motor terminal box fault. These must be fitted externally and on the supply side of the unit. See
“Specifications” section for recommended fuse type and cut-out device.
Operation
Set the ramp time potentiometer to midway to approx 2 seconds and start the system. If the
motor turns instantly when the soft starter is energised and accelerates satisfactorily then no
further adjustment is required. If the rate of acceleration is too great stop the unit and turn the
ramp time potentiometer clockwise then restart. Adjust anti–clockwise for a shorter ramp time
setting to increase the rate of acceleration. The motor should turn instantly when the soft starter
is energised. If not, rearrange the connection of the starting capacitor as shown in fig 1
For running currents up to and including 10 Amps the unit is rated for continuous duty.
Start currents must never exceed 60A.
Earth/Ground
Neutral
Live
Motor connected for
Capacitor Start - Run
110/230V~
N
L
M
N
M
page 3 M-1945-F 100226
L
Connect Start Capacitor
to Supply live for
High Torque or Heavy starting
Run
Cap
Start
Cap
Centrifugal or voltage
switch controls
start Capacitor
M
’ and ‘N
Typical connection
for the HFE.
Extra starting torque
may be needed for
loads which have a
particularly ‘sticky’
starting characteristic.
This can be achieved by
rearranging the internal
connection of the
starting capacitor,
bringing the connection
out and to the supply
side of the starter as
shown.
M
’ to the motor or

Related parts for HFE1