312EXE1D-OL ABB, 312EXE1D-OL Datasheet

no-image

312EXE1D-OL

Manufacturer Part Number
312EXE1D-OL
Description
STARTER, DOL, 15KW, 230V
Manufacturer
ABB
Datasheet

Specifications of 312EXE1D-OL

No. Of Phases
Three
Power Rating
20hp
Current Rating
30A
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
IEC 947-4-1
Coil Voltage Vac Nom
230V
External Depth
156mm
External Length / Height
248mm
For Use
RoHS Compliant
Rohs Compliant
Yes
For Use With
Electric Motor
=
DOL Starters Type EXE0D
Plastic Enclosure to IP66
Installation Instructions
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
Ratings
Note: This product is not suitable for d.c. applications.
Terminal capacity
= = = =
Order references
Coil Voltages (50Hz)
230V
122EXE0D-OL
1TVL300212E5099
182EXE0D-OL
1TVL300216E5099
Contactor
Overload
=
Remove cover from starter.
Select and fit Overload (see ratings chart below).
Connect leads provided from - terminal 14 to Overload 95 and terminal A2 to Overload 96.
Check operating coil voltage and frequency.
Remove appropriate top/bottom knockouts. Attach conduit bushes to conduit.
Mount base and connect to bushes. If continuous grounding is required fit separate bonding strip
For on-site control circuit conversions see overleaf.
Connect cables and ensure that all terminations are tight.
When installed, set the Hand/Auto selector and adjust the current calibration to the desired value. (See below)
Replace cover and secure
Note: If an extra control device is required, see overleaf.
Main
1 x 4mm
or
2 x 2.5mm
1 x 10mm
or
2 x 6mm
400V
124EXE0D-OL
1TVL300412E5099
184EXE0D-OL
1TVL300416E5099
2
2
2
2
Issue 10
Auxiliary
1 x 4mm
or
2 x 2.5mm
2 x 2.5mm
Requires
Overload
TA25DU1.4
1SAZ211201R1023
TA25DU1.8
1SAZ211201R1025
TA25DU2.4
1SAZ211201R1028
TA25DU3.1
1SAZ211201R1031
TA25DU4.0
1SAZ211201R1033
TA25DU6.5
1SAZ211201R1038
TA25DU11
1SAZ211201R1043
TA25DU14
1SAZ211201R1045
TA25DU19
1SAZ211201R1047
2
2
2
Overload
rating
Full load A
min.
1.0
1.3
1.7
2.2
2.8
4.5
7.5
10.0
13.0
max.
1.4
1.8
2.4
3.1
4.0
6.5
11.0
14.0
19.0
Summary
A direct-on-line motor starter with ingress protection to
IP66. Two-tone plastic enclosure with ABS lid and
base.
Trip class 10 requirements IEC 947-4-1
= = = =
= = = =
NOTE: FLC = Full load current
1.05 x FLC
1.2 x FLC
1.5 x FLC
7.2 x FLC
Approximate motor rating
400V/3PH
AC3
KW
0.37
0.55
0.75
1.1
1.5
2.2
4.0
5.5
7.5
hp
0.55
0.75
1.0
1.5
2.0
3.0
5.5
7.5
10.0
No tripping
Trip within 2 hours
Trip within 4 minutes
Trip between 4s and 10s
230V/1PH
AC3
KW
0.07
0.1
0.18
0.25
0.37
0.55
1.1
1.5
2.2
hp
0.09
0.125
0.25
0.33
0.5
0.75
1.5
2.0
3.0
Recommended
max. fuse size for
short circuit
protection A
4
10
20
35
ABB
IEC947-4-1

Related parts for 312EXE1D-OL

312EXE1D-OL Summary of contents

Page 1

... A AC3 0.55 0.07 0.09 4 0.75 0.1 0.125 1.0 0.18 0.25 10 1.5 0.25 0.33 2.0 0.37 0.5 20 3.0 0.55 0.75 5.5 1.1 1.5 7.5 1.5 2.0 35 10.0 2.2 3.0 No tripping Trip within 2 hours Trip within 4 minutes Trip between 4s and 10s ABB ...

Page 2

... Council of European Communities Directives: The products in this publication conform to relevant EEC Directives and EN Standards. Installation and use of such products must be carried out by competent, properly trained personnel, complying with any instructions supplied by ABB. Liability for improper incorporation, assembly, use, processing, storing or handling of goods remains the sole responsibility of the individual, or company carrying out such work ...