XCS-PA792 TELEMECANIQUE, XCS-PA792 Datasheet - Page 5

SAFETY SWITCH, 2NC

XCS-PA792

Manufacturer Part Number
XCS-PA792
Description
SAFETY SWITCH, 2NC
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of XCS-PA792

Contact Voltage Ac Max
250V
Contact Voltage Dc Max
24V
Contact Current Ac Max
6A
Contact Current Dc Max
540mA
Switch Terminals
Cage Clamp / Screw
Approval Bodies
EN1088, EN60204, EN60947-5-1
2
Dimensions :
pages 2/34 and 2/35
Schemes :
page 2/36
Type of switch
For UK market, please refer
to pages 2/28 and 2/29
References of switches without actuator
2-pole N/C + N/O
break before make
slow break (2)
2-pole N/O + N/C
make before break
slow break (2)
2-pole N/C + N/C
slow break (2)
3-pole N/C + N/O + N/O
(2 N/O staggered)
slow break (2)
3-pole N/C + N/C + N/O
(N/O staggered)
slow break (2)
3-pole N/C + N/C + N/C
slow break (2)
Weight (kg)
Complementary characteristics
Actuation speed
Resistance to forcible
withdrawal of actuator
Mechanical durability
Maximum operating rate
Minimum force for positive opening
Cable entry
References of accessories
Description
Set of 10 blanking plugs for operating head slot
Tool for forced opening of interlocking device
(1) Adjustable throughout 360 in 90 steps. Blanking plug for operating head slot included with switch.
(2) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch.
2/30
Te
Components for safety applications
Guard switches
Double insulated, turret head
Cable entries tapped for Pg 11 (n 11) cable gland
References, characteristics
Without locking of the actuator
XCS-PA591
XCS-PA691
XCS-PA791
0.110
Maximum : 0.5 m/s, minimum : 0.01 m/s
XCS-PA, XCS-TA : 10 N (50 N using actuators XCS-Z12 or XCS-Z13 together with guard retaining device XCS-Z21)
XCS-TE : 500 N
XCS-PA, XCS-TA : > 1 million operating cycles
XCS-TE : 1 million operating cycles
For maximum durability : 600 operating cycles per hour
15 N
XCS-PA, XCS-TE : 1 entry tapped for n 11 cable gland conforming to NF C 68-300 (DIN Pg 11).
XCS-TA: 2 entries tapped for n 11 cable gland conforming to NF C 68-300 (DIN Pg 11).
Clamping capacity 7 to 10 mm.
not shown under general characteristics (page 2/15)
(Sold in lots of 10)
(
N/C contact with positive opening operation)
(1)
, types XCS-PA, XCS-TA and XCS-TE
For use with
guard switches
XCS-PA, XCS-TA,
XCS-TE
XCS-TE
XCS-TA591
XCS-TA791
XCS-TA891
0.160
Unit
reference
XCS-Z28
XCS-Z100
Weight
0.050
0.050
kg

Related parts for XCS-PA792