D4N3262 Omron, D4N3262 Datasheet - Page 20

LIMIT SWITCH, ROLLER LEVER, 2NC

D4N3262

Manufacturer Part Number
D4N3262
Description
LIMIT SWITCH, ROLLER LEVER, 2NC
Manufacturer
Omron
Type
Limit Switchr
Datasheets

Specifications of D4N3262

Actuator Style
Roller Lever
Operating Force Max
5N
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
2.5A
Switch Terminals
Screw
Switch Function Configuration
N.C.
Current Rating (max)
3A
Operating Temp Range
-30C to 70C
Lead Free Status / RoHS Status
na
Wiring
• When connecting to the terminals via insulating tube and M3.5
One-conduit Type (3 Poles)
Two-conduit Type (3 Poles)
• Do not push crimp terminals into gaps in the case interior. Doing so
• Use crimp terminals not more than 0.5 mm in thickness. Otherwise,
B-24
C
A
E
J.S.T.
crimp terminals, arrange the crimp terminals as shown below so
that they do not rise up onto the case or the cover. Applicable lead
wire size: AWG20 to AWG18 (0.5 to 0.75 mm
Use lead wires of an appropriate length, as shown below. Not doing
so may result in excess length causing the cover to rise and not fit
properly.
may cause damage or deformation of the case.
they will interfere with other components inside the case. The crimp
terminals shown below are not more than 0.5 mm thick.
Manufacture
J.S.T is a Japanese manufacturer.
11
21
33
12
22
34
A
C
E
dz dia.: 3.7 mm
D dia.: 2.9 mm
Crimp terminal
Safety Limit Switch
B: 6.6 mm
B
D
F
L: 19 mm
F: 7.7 mm
I:
t: 0.5 mm
11
21
33
42 mm
8.0 mm
12
22
34
FV0.5-3.7 (F type)
V0.5-3.7 (straight type)
Incorrect
Correct
Left hand
E
D dia.
D
C
B
F
A
B D F
Type
Tolerance 2 mm
28 mm
l
E
C
Dog
A
B
D4N
L
Correct
Incorrect
D
28 mm
F
F
dz dia.
AWG20 (0.5 mm
Tolerance 2 mm
28 mm
Terminal screw
Right hand
2
).
E
33 mm
C
Wire size
A
B D F
42 mm
B
Tolerance 2 mm
42 mm
2
)
Contact Arrangement
• The following diagrams show the contact arrangements used for
Screw Terminal Type
Connector Type
• Applicable socket: XS2F (OMRON).
• Refer to the Connector Catalog for details on socket pin numbers
Socket Tightening (Connector Type)
• Turn the socket connector screws by hand and tighten until no
• Make sure that the socket connector is tightened securely.
Conduit Opening
• Connect a recommended connector to the opening of the conduit
• When using 1/2-14NPT, wind sealing tape around the joint between
• Use a cable with a suitable diameter for the connector.
• Attach and tighten a conduit cap to the unused conduit opening
Changing the Lever
The lever mounting screws can be used to set the lever position to
any position in a 360 angle at 7.5 increments. Grooves are incised
on the lever and rotary shaft that engage to prevent the lever from
slipping against the rotary shaft. The screws on adjustable roller
lever models can also loosened to change the length of the lever.
Remove the screws from the front of the lever before mounting the
lever in reverse (front/back), and set the level so that operation will be
completed before exceeding a range of 180 on the horizontal.
D4N-@D@@ (3NC)
D4N-@B@@ (2NC)
D4N-@2@@ (2NC (SNAP))
D4N-9B@@ (2NC)
D4N-92@@ (2NC (SNAP))
screw terminal types and connector types.
and lead wire colors.
space remains between the socket and the plug.
Otherwise, the rated degree of protection (IP67) may not be
maintained and vibration may loosen the socket connector.
and tighten the connector to the specified torque. The case may be
damaged if an excessive tightening torque is applied.
the connector and conduit opening so that the enclosure will
conform to IP67.
when wiring. Tighten the conduit cap to the specified torque. The
conduit cap is provided with the Switch (2-conduit types).
(1) 11
(3) 31
Pin No. (Terminal No.)
11
21
31
11
31
2
1
3
4
12 (2)
32 (4)
12
22
32
12
32
D4N-9A@@ (1NC/1NO)
D4N-9E@@ (1NC/1NO (MBB))
D4N-91@@ (1NC/1NO (SNAP))
D4N-@C@@ (2NC/1NO)
D4N-@F@@ (2NC/1NO (MBB))
D4N-@A@@ (1NC/1NO)
D4N-@E@@ (1NC/1NO (MBB))
D4N-@1@@ (1NC/1NO (SNAP))
(3) 13
(1) 31
(1) 11
(3) 33
13
31
11
21
33
11
33
12 (2)
34 (4)
14 (4)
32 (2)
12
22
34
12
34
14
32

Related parts for D4N3262