T4820000 Red Lion Controls, T4820000 Datasheet - Page 7

Process/Temperature Controller

T4820000

Manufacturer Part Number
T4820000
Description
Process/Temperature Controller
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheet

Specifications of T4820000

Operating Temperature Max
50°C
Operating Temperature Min
0°C
Temperature Accuracy ±
0.3%
Output Voltage Max
7VDC
Output Voltage Min
4V
Controller Input
Thermocouple Or RTD
Brand/series
T48 Series
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Height
1.95 in.
Input Type
RTD/Thermocouple
Ip Rating
IP65
Length
4.17 in.
Memory
EEPROM
Mounting Type
Panel
Output Type
Digital/SSR
Power Consumption
8 VA (Max.)
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE
Termination
Screw
Time, Response
400 ms (Max.)
Voltage, Supply
85 to 250 VAC
Width
1.95 in.
Panel Cutout
1.77" × 1.77" (1⁄16 DIN)
Power Requirements
85-250 VAC
Sealing
NEMA 4X/IP65
Operating Temperature
0°C to +50°C
Thermocouple Type
J, K, T, E, R, S, B, N, Linear MV
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
APPLICATION
PLASTICS EXTRUDER APPLICATION
temperature of a plastics extruder. Each T48 controls a
heating element and a cooling water solenoid to maintain
each extruder zone at the desired temperature. The Heater
Current Monitor option is used to provide a readout of the
heater current. The multi-function User Input can be
programmed to allow selection of manual operation when
connected to common. This allows the user to hold the
control output of the controller during abnormal process
conditions.
MULTIPLE UNIT/REMOTE SETPOINT APPLICATION
within the oven. Depending upon the material to be dried, and its initial
moisture content, the drying setpoint temperature varies. A master T48
controller transmits setpoint via linear DC output. This signal is received as
a remote setpoint signal by the other slave controllers.
Several T48 controllers are employed to control the
Eight T48 controllers are used in a drying oven. Each T48 controls a zone
7
Whenever the master controller’s setpoint is changed, the slave controller’s
setpoint changes automatically.
independently.
The remote setpoint input at each slave controller can be scaled
(Terminal assignments are model number dependent.)
OEM PAINT SPRAYER APPLICATION
the T48 to maintain optimum paint temperature. In addition to
the low cost, the 1/16 DIN package size permits the OEM to
design temperature control into various sized painting
equipment, from small hand sprayers to large paint booths. The
heating element used to heat the paint, is connected to the Main
Control Output (OP1) programmed for On/Off control. Alarm 1
is programmed as Band Inside Acting, so that as long as the
paint temperature is within manufacturer’s specifications for
temperature, the “GO” light is on. Alarm 2 is programmed as
Band Outside acting so that the “NO GO” light is lit when the
paint temperature is more than 12° outside the manufacturer’s
specifications of 140 to 150°F.
(Terminal assignments are model number dependent.)
(Terminal assignments are model number dependent.)
An OEM manufacturing spray painting equipment utilizes