Specifications of NT600SST211BEV3

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free / RoHS Compliant
242
Graphs
Touch switches for display function
Line
Value
Table Entry:
Display %:
Line
Color:
Style:
100%
Table Entry: Specify this item if a 100% value is set with a numeral memory
Value:
0%
Table Entry: Specify this item if a 0% value is set with a numeral memory
Value:
–100%
Table Entry: Specify this item if a –100% value is set with a numeral memory
Value:
Restart :
(Continue)
Stop:
Display Clear:
(Clear display)
Next Page:
(Forward)
Previous Page:
(Rewind)
Log Clear:
(Clear log)
Specify the graph (line) color.
(Can only be set for PTs with color display.)
White, black, blue, red, magenta, green, cyan, yellow
Specify the line type.
Solid, Dash, Dot-dash, Dot-dot-dash
table entry: set the table entry number of the numeral memory
table.
Specify this item if a 100% value is set with a constant:
set the value to be taken as the 100% value.
table entry: set the table entry number of the numeral memory
table.
Specify this item if a 0% value is set with a constant:
set the value to be taken as the 0% value.
table entry: set the table entry number of the numeral memory
table.
Specify this item if a –100% value is set with a constant: set the
value to be taken as the –100% value.
Specify the table entry number of the numeral memory table
entry whose contents are displayed in a trend graph.
the screen.
Specify whether or not a percentage value is displayed on
Specify whether or not a touch switch used to restart
the halted data sampling is used.
Specify whether or not a touch switch used to halt
data sampling is used.
Specify whether or not a touch switch used to clear
the graph display is used. Note that the log data is
not cleared by this switch.
Specify whether or not a touch switch used to
move the display range in the direction of newer
records is used.
Specify whether or not a touch switch used to
move the display range in the direction of older
records is used.
Specify whether or not a touch switch used to
clear all logged data is used.
Section
6-9