OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
Running the Test in Loopback Mode
1
2
3
4
5
6
7-24
If you disconnected the reference test cord from
the tester’s output, you must set the reference
again to ensure valid measurements.
Verify that the settings described in Table 7-1 are
appropriate. Let the tester warm up for 5 minutes.
Select Loss/Length mode: On the HOME screen, press
A
Clean the connectors on the cabling to be tested.
Connect the tester to the cabling as shown in Figure
7-10.
Press
To save the results, press
ID; then press
Change Test; then select Loss/Length.
T
to start the loss/length test.
s
W
again.
Caution
s
; select or create a fiber
Loopback Mode Test Results
The SUMMARY screen, which appears when the test is
finished, is described in Table 7-6.
To see more detailed results, press
7-7 describes the RESULTS screen.
A
View Results. Table