K8AB-PH1 Omron, K8AB-PH1 Datasheet - Page 7

3-phase Seq Loss Ry.200-500

K8AB-PH1

Manufacturer Part Number
K8AB-PH1
Description
3-phase Seq Loss Ry.200-500
Manufacturer
Omron
Series
K8ABr

Specifications of K8AB-PH1

Contact Form
SPDT
Coil Voltage
200 VAC to 500 VAC
Contact Rating
6 A at 250 VAC
Mounting Style
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
K8ABPH1
Z2806
Monitoring Phase Sequence/
Phase Loss for Escalators
Monitoring Compressor Power Supplies
Controlling the Liquid Level in a Tank
L1 L2 L3
Motor
Compressors cannot operate correctly under conditions such as
under voltage, asymmetry voltage, phase loss, or phase
sequence. The K8AB-PM can be used to monitor 3-phase
voltage, the phase sequence, and phase loss.
A single K8AB-PM can monitor over voltage, under voltage, the
phase sequence and phase loss in 3-phase voltage. It can also
output individual alarms for over voltage or under voltage using an
SPDT relay. The K8AB-PM is able to recognize which alarm has
occurred.
The 61F-D21T-V1 can be used to control the liquid level in a tank.
Fixed type
Because the sensitivity resistance can be adjusted from 10 to 100 kW, there is
no need to change models to match different liquid types and concentrations.
You can also set the operation time in a range of 0.1 to 10 seconds to prevent
operating errors due to chattering.
Water supply and draining control can be changed by DIP switch.
Purpose
Advantages
Purpose
Advantages
J7L Contactor
Relay output:
6 A at 250 VAC
(resistive load)
K8AB-PH
Phase-sequence and
phase-loss monitoring
(Phase loss during motor operation cannot be detected.)
Mobile type
The K8AB-PH detects the phase sequence or
phase loss in escalator power supplies.
A single K8AB-PH can detect the phase
sequence or phase loss at startup.
Purpose
Advantages
61F-D21T-V1
K8AB-PM
3-Phase voltage,
phase-sequence,
and phase-loss monitoring
61F-D21T-V1
Conductive level control
L1 L2 L3
Load
K8AB-PH
K8AB-PM
Relay
output:
6 A at
250 VAC
(resistive
load)
J7L Contactor
Monitoring Generated Voltage
Monitoring Voltage Generated
by Wind-powered Generators
High voltage
Wind-powered generator
reception
L1 L2 L3
Load
K8ABA-PW
3-Phase voltage
monitoring
Power grid panel
The K8AB-PW monitors the voltage of power generated by a
generator. It also detects over voltage and under voltage in power
from a generator.
A single K8AB-PW can monitor 3-phase voltage. It can also
output individual alarms for over voltage and under voltage using
SPDT relays because it features two outputs with SPDT relays.
The voltage measurement range can be switched from 200 to 480
VAC and the K8AB-PW can be switched to monitor phase voltage
or line voltage.
protection relay
OCR, RPR
UVR, OVR
Power grid
Purpose
Advantages
The K8AB-PW detects over voltage and under
voltage in power generated by a wind-powered
generator.
A single K8AB-PW can be used for a 3-phase power
supply with 3 or 4 wires. It can be used to individually
set and output over voltage and under voltage
alarms.
N
Purpose
Advantages
monitoring panel
Generator
L1
PLC
L2
L3
K8AB-PW
Simultaneous 3-phase
over and under voltage
monitoring
K8AB-PW
K8AB-PW
Generator
7