Incremental Rotary Encoder

SE-360

Manufacturer Part Number
SE-360
Description
Incremental Rotary Encoder
Manufacturer
Simpson
Datasheets

Specifications of SE-360

No. Of Channels
2
Rotational Speed Max
6000rpm
Supply Voltage Range
12VDC To 28VDC
Pulses Per Revolution
360
Encoder Output
Quadrature
Operating Temperature Range
0°C To +65°C
Equipment Type
Encoder
Sensor Supply Voltage
12VDC To 28VDC
Rohs Compliant
No
Encoder Resolution
360CPR
Encoder Type
Incremental
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
• Four model types designed to fit a wide
• One meter to measure all your values
• Easy installation - software detection/
• Wide backlit LCD display for easy viewing
• Easy to use - four keys select all parameters
• Use for single or three-phase applications
range of applications
correction of wiring errors
INPUT
System
Voltages
Current
Measurement range
Operating Frequency
Harmonics
Input Loading
Overload
Auxiliary Supply
General Display
ENVIRONMENTAL
Temperature
Humidity
Programming
CT Primary
VT Primary
Pulse Outputs
Function
Pulse Length
Isolation
Scaling
ACCURACY
Current
5% to 120%FS
Voltage LN
20% to 120%FS
Voltage LL
20% to 120%FS
Watts
5% to 120%FS
VA
5% to 120%FS
var
5 % to 120%FS
PF
Frequency
Neutral Current
5% to 120%FS
Wh Register
VAh Register
Varh Register
Note:
MECHANICAL
Bezel
Depth
Panel Cutout
Weight
Height
Specifications
Measurement range
Voltage
Current
Voltage
Current
Standard
Optional
Output No. 1
Output No. 2
3-phase, 3 or 4 wire unbalanced load
120/208, 120/240, 277/480, 63/110
0.5% to 120%
5 amp from external CTs Fully Isolated
0.5% to 120%
45 to 65 Hz
Up to the 20th harmonic
Less than 0.1VA per phase
Less than 0.1VA per phase
x2 for 2 seconds max.
x40 for 1 second max.
115V±15% 45-65Hz
230V±15% 45-65Hz
Custom backlit supertwist LCD 3 lines of .47”
(12mm) digits plus .15” (3.8mm) legends
14°F to 149°F (-10°C to 65°C) operating
<75% RH non-condensing
5amp to 6500 amp
60v to 50,000v
2
Wh (G200, G300 & G400 only)
Total varh (G300 & G400 only)
100ms
2500V (50 Output No. 1 to Output No. 2)
Settable 1, 10 or 100 pulse output rate
All accuracies specified are ±1 digit
*Rdg = Reading
2.77” x 3.79” (w/ .28” lip)
2.83”
3.62” x 3.62”
14 oz.
3.79”
Per Phase
±0.2%FS
±1% Rdg*
±0.2%FS
±1% Rdg*
±0.3%FS
±1% Rdg*
±0.4%FS
±1% Rdg*
±0.6%FS
±1.5% Rdg*
±0.8%FS
±2% Rdg*
±0.2°
N/A
N/A
N/A
N/A
N/A
3 Phase
N/A
N/A
N/A
±0.6%FS
±1% Rdg*
±1%FS
±1.5% Rdg*
±1.5% FS
±2% Rdg
±0.2°FS
±0.05 Hz
±0.6% FS
±2% Rdg
Class 1
EN 61036
Class 2
Class 2
IEC 1268