SE-360 Simpson, SE-360 Datasheet

Incremental Rotary Encoder

SE-360

Manufacturer Part Number
SE-360
Description
Incremental Rotary Encoder
Manufacturer
Simpson
Datasheets

Specifications of SE-360

No. Of Channels
2
Rotational Speed Max
6000rpm
Supply Voltage Range
12VDC To 28VDC
Pulses Per Revolution
360
Encoder Output
Quadrature
Operating Temperature Range
0°C To +65°C
Equipment Type
Encoder
Sensor Supply Voltage
12VDC To 28VDC
Rohs Compliant
No
Encoder Resolution
360CPR
Encoder Type
Incremental
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Related parts for SE-360

SE-360 Summary of contents

Page 1

...

Page 2

... From the analog meter used in Charles Lindbergh’s historic solo trans-Atlantic flight in 1927 to the digital controllers used to raise and lower stages at the 2004 MTV Video Music Awards (VMAs) show or the MiniMax meters which monitor the lighting at CNN, Simpson continues to pro- vide solutions for a wide variety of electrical, electronic and environmental testing and measuring applications ...

Page 3

... Mini M135 & M145 . . . . . . . . . . . . . . . . .A1-A2 MiniMax M235 & M245 . . . . . . . . . . . . . .A3-A4 MiniMax M240 Temperature Meter . . . . .A5-A6 Falcon F35 & F45 . . . . . . . . . . . . . . . . . .A7-A9 2800 Series . . . . . . . . . . . . . . . . . . . . . . . . .A10 Hawk 3 H335 & H345 . . . . . . . . . . . . .A11-A12 Hawk 3 H340 Temperature Meter . . . .A13-A14 GIMA 3-Phase Power Meter . . . . . . . .A15-A17 S660 Preset Totalizer/Counter . . . . . . . . . .A18 S661 Preset Rate Counter ...

Page 4

... Since there is a space between the pointer and the face of the meter scale, an analog pointer will seem different positions on its scale, depending on the angle from which it is read.) Digital panel meters, such as the Simpson ...

Page 5

... LCD 0.5" (12.7mm position user-programmable Most significant = "1" other digits blank Optional negative image, red backlighting at 5, 10, 12 DCV Auto with "-" indication, "+" indication implied ±5V, +5V and +9V Low Power Indication included with 9V units 2mA max 50mA typical ...

Page 6

... A 2 Ordering Information Mini Indicators can be configured by making an entry in each section. Example: M135-0-2-11-0 Selection M135 M145 Installation and Panel Cutout Basic Display DPM Power Function/ Unit Supply Description Selection Basic Unit / 3- Digit LCD Digit LCD Display Non Backlit 21 Negative Red Backlight ...

Page 7

... Less than 20 minutes 60dB, 50/60Hz (w/1K unbalanced @ 60Hz) 90dB min Integrating 3 samples/second typical Frequency-to-voltage 500mV to 750VRMS at 1.0M impedance 24V Square Wave (DC offset 2V max) 0.94” x 2.83” 2.36" 0.89" x 2.71" (22.6mm x 68.8mm) 3.5oz (99g) 94-0,UL-rated, glass-filled thermoplastic DC Process Max Input ...

Page 8

... A 4 Ordering Information Mini-Max Indicators can be configured by making an entry in each section. Example: M245-1-0-71-0. Selection M235 M245 Not Available on Frequency (Hz) Meters Basic Display DPM Power Unit Supply Description Selection Basic Unit / Digit LCD Digit LCD Display Non Backlit 41 Negative Red Backlight 42 43 ...

Page 9

... DIN Temperature Indicator • Jumper-selectable input type and ºC/ºF indication • Screw terminal connectors for easy installation • Unique mounting bracket allows for stacking of multiple meters Dimensions - M235, M245 & M240 2.66” Specifications DISPLAY Type Height Display resolution ...

Page 10

... A 6 Ordering Information Mini-Max Indicators can be configured by making an entry in each section. Example: M240-0-91-0-F. Selection M240 Mounting Requirements Insert the Mini-Max through the panel, and then slide the mount- ing bracket on to the Mini-Max. The mounting bracket allows Mini-Max units to be stacked side-to-side or top-to-bottom. ...

Page 11

... Din Rail Adapter available (page C1) Mounting Requirements The Falcon series 1/8 DIN indicators require a panel cutout of 1.77" (45mm) high by 3.62" (92mm) wide. To install the Falcon into a panel cutout, remove the clips from the side of the meter. Slide the meter through your panel cutout, then slide the mount- ing clips back on the meter ...

Page 12

... Less than 15 minutes Response Time Less than 3 seconds CONVERSION Technique Frequency-to-voltage Rate 3 samples per second, nominal ACCURACY @ 25°C F35 ACA ±1% of reading ± 5 counts (45Hz - 1 kHz) F45 ACA ±0.5% of reading ± 35 counts (45Hz - 1kHz) F35 ACV ±0.1% of reading ± 5 counts (45Hz - 1kHz) F45 ACV ± ...

Page 13

... Ordering Information Falcon Indicators can be configured by making an entry in each section. Example: F45-1-52-0. Basic Unit Selection Description Basic Unit 3 1/2 digit LED F35 4 1/2 digit LED F45 Power Supply 120 ACV 1 220 ACV 9-32 DCV† 4 120 ACV* Function/Range 200 DCmV 11 2 DCV ...

Page 14

... Mounting Instructions The 2800 indicators are installed with the mounting hardware provid- ed. Slide the meter through the panel cutout. Next, insert a side mounting bracket to each side of the meter. Use the two holes located near the bezel to attach them to the meter. Slide the brack- ets back until they lock into the meter ...

Page 15

... All parameters set from easy to understand front panel access • One, two or four 5-amp relays optional • Five user-selectable brightness levels •1/8 DIN, shallow depth case, 3.24” • RS485 digital communications optional (H345) • DCV power supply output optional • ...

Page 16

... A 12 Ordering Information Hawk 3 Indicators can be configured by making an entry into each section. Example: H335-3-71-0-4-1 Basic Unit Selection H335 H345 1 120 ACV (3-1/2 only) 2 85-250 ACV (4-1/2 only) 9-36 DCV 3 85-250 ACV (3-1/2 only) 4 200 DCmv 11 2 DCV DCV 14 200 DCV 15 600 DCV* 21 200 DCµ ...

Page 17

... One, two or four 5-amp relays optional • 7-segment 4 digit red LED • Five user-selectable brightness levels • Activated set point indicators on display • Min/Max and password lockout • NEMA 4X rated front panel • RS485 digital communications output available by special order • ...

Page 18

... To replace the engineering unit label, place the tip of a ballpoint pen into the small hole at the base of the engineering label in the bezel. Slide the label up until it pops out. Grasp and remove. Slide the new label half the distance in, then use the ballpoint pen to slide it into place. DC Current ...

Page 19

... One meter to measure all your values • Easy installation - software detection/ correction of wiring errors • Wide backlit LCD display for easy viewing • Easy to use - four keys select all parameters • Use for single or three-phase applications Specifications INPUT System ...

Page 20

... A three-phase terminal style current transformer must be used with GIMA® three phase meters. The current transformer is equipped with terminals to permit easy con- nection to the GIMA units. These terminals are #8-32 brass studs and come with a flatwasher, lockwasher and a regular nut (leads are not provided). ...

Page 21

... This Options Module may be configured as RS485 or RS422 providing 2 or 4-wire communications over distances up to 3,960 feet (3/4 mile). Data rates of 4800, 9600 or 19200 baud may be selected to suit system require- ments. The Communications Option Module is available in two formats: Standard: Only parameters displayed on the GIMA meter can be accessed via Modbus (Cat ...

Page 22

... The control inputs offer several counter operation modes: count/direction, add/add, add/subtract, subtract/subtract, quadrature and reverse quadrature. Optional relay outputs enhance the counter from a passive device to an integral control element for your applica- tion. Panel Cutout Dimensions on page A23 ...

Page 23

... VLT = 1.6V ±10% VUT = 3.6V ±10% VLT = 5.0V ±10% VUT = 7.0V ±10% 20KHz (Pulse Max) 5KHz (Quadrature X4 Max) 30DCV (Max) (Display Hold) Display is frozen when the User Input is pulled low. VLT 0.2DCV guaranteed low, VUT = 3.0DCV (max) VLT 0.9DCV VUT =3.15DCV (max) 0° ...

Page 24

... This versatile counter has latching, boundary or timed (0.01 to 599.99 seconds) output modes. Mounting Requirements The S660 series 1/8 DIN counters require a panel cutout of 1.77" (45mm) high by 3.62" (92mm) wide. To install the counter into a panel cutout, remove the clips from the side of the meter. Slide the meter through your panel cutout, then slide the mounting clips back on the meter ...

Page 25

... Display Scaling Set Point Programming Decimal Point Selection The S663 is a multi-function counter that allows the end user to track the rate (speed product and continuously monitor the product quantity for a given process. The count and rate displays have separate pro- grammable decimal point settings and scaling values. ...

Page 26

... Set Point Programming This counter offers a wide input frequency range from 1Hz to 35KHz, and four display ranges of 99.99Hz, 999.9Hz, 9999Hz, and 35KHz. The easiest to use counter in the S660 counter series, the S664 offers 12 DCV, 100mA sensor excitation and requires no program- ming to use. ...

Page 27

... A Simpson 12” anodized aluminum measuring wheel is the right choice to complete the setup of a length measurement system. Whether the application requires one or two, Simpson’s measuring wheels will perform accurately and reliably throughout the measuring process ...

Page 28

... Shaft Speed--6,000 RPM max. Shaft--stainless steel Bearings--heavy-duty chrome steel Load--30lbs. radial; 10lbs. axial ENVIRONMENTAL 32°F to149°F (0-65°C) Ordering Information SE Quadrature Encoders Pulses Per Revolution 60 100 120 360 600 Installation and Wiring Catalog No. SE-060 SE-100 SE-120 SE-360 SE-600 ...

Page 29

... Simpson Electric offers a wide range of reliable and durable analog panel meters to fulfill your application require- ments. Our products continue to set the standard for quality with each of our analog panel meter families. Century • Rugged black plastic case • Glass window for optimum viewing Round / Rectangular • ...

Page 30

... B 2 • Clear acrylic window for wide angle visibility • Rugged black plastic case • Black spade pointer for easy distant reading • Optional behind-panel mounting bezel kit Dimensions 1-1/2"-Model 1212, 1212T .86 .55 .65 .53 1.76 1.50 DIA. 1.55 .41 DIA. (2) #8-32 STUDS (4) #4-40 MTG ...

Page 31

Model 1379 4-1/2"-Model 1329, 1329T, 1349, 1359 (2) #1/4-28 STUD 4-1/2"-Model 1389 3-1/2"-Model 1327, 1327T, 1347, 1357 B 3 ...

Page 32

... Available on special order * These meters require use of an external current transformer from page C5. AC Voltmeters, , 4-1/2” 3-1/2” Range Model 1359 Model 1357 0-5 06625 06665 0-10 06630 ...

Page 33

... To select the proper shunt, first obtain the full- load current rating of your motor from the name plate, manufacturer's specifications of N.E.C. listing. Multiply that rating by 1.25 and select and order the shunt with an amps rat- ing as large or slightly larger than the calculated value. Installation and calibration instruc- tions are included with the meter ...

Page 34

... Shielding Calibration is unaffected by magnetic panel mounting. Center Scale Value 50/60/400Hz Power Consumption 1.6VA Max. Input Voltage (10 sec) 150, 120V normal 280, 240V normal Dial Each dial arc is calibrated to track the specific type of movement used. Operating Temperature -4°F to +149°F (-20°C to +65°C) ...

Page 35

Dimensions 1-1/2"-Models 2121, 2121T, 2141, MTG HOLES-.125 DIA DRILL THRU 3-1/2"-Models 2123, 2123T, 2143, 2153, 2183 4-1/2"-Model 2174 = Panel Meter Cut-out Dimensions 1 2-1/2"-Models 2122, 2122T, 2142, 2152,2182 3-1/2"-Model 2173 4-1/2"-Model 2124, 2124T, 2144, 2154, 2184 (4) #6-32 MTG. ...

Page 36

... Available on special order. †These meters are 5-amp meters used with an external current transformer. AC Dual Range Ammeter/Voltmeter, Model/Size and Catalog Number Approx. 2-1/2" Impedance (ohms Model Hz 2152 Range 15,030 ...

Page 37

... Type Rating 4-1/2” Model 2124T DC (Note 17585 AC (Note 2) 5 amps 17586 1. These DC meters require an external shunt from page C3, and wire-wound potentiometer (customer supplied). 17587 2. These AC meters require use of a current transformer from page C5. 17588 17590 Frequency Meters, 17592 Approx. Impedance 17594 < ...

Page 38

... B 10 • Clear acrylic case updates panel design • Black knife-edge pointer for precision reading • Special colored scales or logos available Dimensions 1-1/2"-Model 921, 921T, 941 2-1/2"-Model 922, 942 Specifications Accuracy: Movement: Suspension: Tracking: Repeatability: Shielding: Response Time: Overload (1 sec.): ...

Page 39

... TV3AAA075* 0-100 0.008 TV3AAA100* 0.008 0-150 TV3AAA150* 0.008 0-200 TV3AAA200* 0.008 0-300 TV3AAA300* * These meters require use of a current transformer from pages C4-C6 AC Voltmeters, Iron Vane Movement Approx. Model/Size and Catalog Number Impedance 3-1/2" (ohms) @ Model 953 Range 60 Hz 0-5 TV3AVV005 ...

Page 40

... TV1DAA5T5* TV2DAA5T5 1/2” DC current meters are self-contained through 10 amps; 15 amps and higher are supplied as 50mV meters and require an external shunt from page C3. 2 1/2”, 3 1/2” and 4 1/2” meters are self-contained through 50 amps. Higher ranges are 50 mV meters and require an external shunt from page C3 ...

Page 41

... Available on special order. * These meters require use of an external current transformer from page C4-C6 4-20mA Process Meters, Dial indicates 0-100 Percent Approx. Impedance Model/Size and Catalog number (Ohms) Range 4-20 5.0 B ...

Page 42

... Model 45 75-0-75 08010 * DC current meters are self-contained for ranges up to and including 50 amperes. Higher range DC current meters (50 mV) listed above are calibrated for 5' leads and require external shunts. <> Available on special order. 2-1/2" 3-1/2" DC Millivoltmeters, Model 125 ...

Page 43

... Panel Meter Cut-out Dimensions NOTE: “T” model suffix used for Taut-Band movement 2-1/2"-Models 125, 125T, 145, 155, & 185 3-1/2"-Models 25 & 25T, 45, 55, 75, 85 & Model 25 Process Meter 3-1/2"-Model 75 .16 DIA. DRILL THRU. (3) MTG. HOLES REQ’D 120 APART .16 DIA. DRILL THRU. (3) MTG. HOLES REQ’ ...

Page 44

... Overload (Continuous) 1.5 times F.S. Repeatability 2%, tautband: .5% Dial Sharp clear scale. Each dial arc is calibrated to track the specific type of movement used Resistance ±15% of meter impedance Pointer Spade pointer with black, matte finish Scale Length Models 177 & 157: 1.6” (40.6mm) Models 147, 127 & ...

Page 45

Dimensions 3-1/2"-Models 27 & 27T, 47, 57, & 1/2”-Model 29, 29T, 49, 59, 79 & 89 2-1/2"-Model 177 3-1/2"-Model 1/2”-Model 79 2-1/2"-Model 127 & 127T, 147, 157, & 187 MTG. Holes - .140 DIA ...

Page 46

... Model 27 Model 29 † DC current meters are self-contained for ranges up to and including 50 amperes. Higher range DC current meters (50 mV) listed above are calibrated 06930 06950 for 5'. leads and require external shunts. 06940 <> Available on special order. ...

Page 47

... Available on special order. † These meters are 5 amp meters with scales as indicated and require external donut transformers from pages C4-C5. AC Voltmeters Rectifier Type, Range 3-1/2" 4-1/2” 0-1 Model 49 0-3 ...

Page 48

... Overload (Continuous): 1.5 times F.S. Repeatability: 2%, 5% for taut band Dial: Sharp clear scale. Each dial arc is calibrated to track the specific type of movement used. Case: High density black plastic Resistance: ±15% of meter impedance Operating Temperature: -4°F to +149°F (-20°C to +65°C) ...

Page 49

... DC Millivoltmeters, 4-1/2” Model 524 Approx. Impedance 15087 Range (Ohms 15089 10.0 0-50 15091 15093 15094 15095 15097 DC Voltmeters, Self-Shielding Movement 15096 Approx. Impedance Range (Ohms 0-5 0-10 0-15 1000 ohms 0-30 per 4-1/2” volt 0-50 Model 524T 0-100 ...

Page 50

... F.S. Overload (Continuous): 1.5 times F.S. Repeatability: 2% Dial: Sharp clear scale. Each dial arc is calibrated to track the specific type of movement used. Case: Metal shielded cover with black matte finish Resistance: ±15% of meter impedance Operating Temperature: -4°F to +149°F (-20°C to +65°C) ...

Page 51

... Range 0-1.5 0-10 0-15 1000 0-25 ohms per volt 0-50 0-100 0- 500 <> Available on special order. Self-Shielding Movement Model/Size and Catalog Number 3-1/2” 4-1/2” Model 3323 Model 3324 16055 16150 16060 16155 Self-Shielding Movement Model/Size and Catalog Number 3-1/2” ...

Page 52

B 24 Model 1357ET/Wide-Vue Model 112ET Model 55ET/Round Model 109ET Model 2153ET/Century Model 57ET/Rectangular ...

Page 53

... Record “on” time of electrical equipment • No reset capability means virtually tamper- proof • Choice models • 2 sizes and 6 different case styles Dimensions 1-1/2"- Model 109ET 3 - 1/2”- Model 55ET 3 - 1/2”- Model 57ET 3 - 1/2”- Model 1357ET B 25 more>> ...

Page 54

... Specifications Accuracy: Models 109ET & 112ET; <.01%/24HRS. Models 55ET, 57ET, 1357ET & 2153ET: Synchronous with AC power Movement: Synchronous clock motor Overload (1 sec.): 10 times F.S. Maximum Indication: 99,999.9 hours Power Consumption: Models 109ET, 112ET: .5 watts All other models: 2.5 watts Case: ...

Page 55

... Excellent readability -- more than double the scale length of standard movements • Sealed round metal or square plastic cases with glass windows • Zero adjust from front panel Specifications Accuracy: AC: ±3% full scale (F.S.) DC: ±2% full scale (F.S.) Movement: AC: Rectifier type, DC: self-shielded, permanent ...

Page 56

... Ordering Information B 28 Percent Motor Load Meters , Self-Shielding Movement Model/Size and Catalog Number Approx. Impedance 3-1/2” Range (Ohms) @ 60Hz Model 2543 0-5 ACA Motor Load 0.5VA Maximum* Current** * Internal transformer burden ** Dial reads 0-150% Motor Load Current < > Available on special order ...

Page 57

... Auto/Manual Reset: Latching function can be enabled independently for each relay by removing jumpers on terminal block Contacts/Output Relay: DPDT relay contacts for each control point; Each set of contacts rated at 5 amps, 120/240 VAC resistive. Frequency Response: 50-1000Hz Power: 108-132 VAC, 50-400Hz Operating Temperature: +41° ...

Page 58

... Single Set Dual 0 to 2500°F (0°C to +1371°C) Point Set Point Thermocouples are not supplied. Available separately from Accessory Section, page 21669 21629 C2 Self-Shielding Movement Model/Size and Catalog Number 3-1/2” Model 4-1/2” Model ...

Page 59

... DIN Rail Mounting Bracket • Fits Simpson Hawk 3, Falcon and Counters • Fits Standard Din Rail Ordering Information Din Rail Adapter Specifications Enclosure: UL94V-0 Rated ABS Attachment Clips: Spring Steel Stiffeners: Steel Installed depth: 4.20” from top of DIN Rail to front of ...

Page 60

... Cat. No. THJ105 THJ1015 THK105 THK1015 THJ035 THJ315 Compression Fitting This adjustable fitting can be applied at any point along the sheath used to mount a thermocouple assembly at a given depth mount a thermocou- ple head on an assembly. Ordering Information Catalog Max. Operating Single Threaded Number Temperature ...

Page 61

Shunts Portable 150 amp Catalog No. 06714 Switchboard 100 amp Catalog No. 06500 Ordering Information Switchboard 50mV Shunts Portable 50mV Shunts Range Cat. Number Range Cat. Number 100 06500 1 06700 150 06503 5 06703 200 06504 10 06704 ...

Page 62

... Current Transformers Model 186 Current Transformer C 4 • Optimal for remote sensing of AC current signals • Converts AC current signal to 0-10 ACV signal • For use with rectifier type analog panel meters or digital indicators • Perfect for low current measurement where a donut current transformer would ...

Page 63

... Dimensions Accuracy For 2 VA Burden .8% .6% .5% .5% .5% .3% .3% Turns Catalog Dimensions Secondary Ratio Number 10:1 01293 5 15:1 01306 3.56” 1.56” 5 20:1 01297 5 30:1 01298 5 40:1 01299 5 50:1 01313 5 60:1 01300 3.56” ...

Page 64

... A 300:5 Current Transformer. 300p 60s 5s 1p (In practicality one turn is dropped from the secondary as a ratio correc- tion factor.) The ratio of the current transformer can be modified by altering the number of secondary turns by forward or backwinding the secondary lead through the window of the current transformer. By adding second- ary turns, the same primary current will result in a decrease in second- ary output ...

Page 65

... AC Volts - 166 Ohms/Volt Used only with Simpson AC Volt, iron vane analog panel meters or with a 0- 200 VAC digital meter using an external 25 /1W resistor across the inputs. Voltage Voltage Impedance Drop Range Reduced @ 60 Hz 0-500 ...

Page 66

... Removable front cover allows access to programming buttons or scaling potentiometers Dimensions Specifications Lens Material Clear 94-V-0 UL-rated polycarbonate with UV inhibitor Gasket Material Closed Cell Neoprene Bezel Material Steel Bezel Finish Black Polyurethane Bezel Dimensions 4.3” x 2.41” x 0.28” (109.2mm x 61.2mm x 7.1mm) Overall Dimensions 4.3” ...

Page 67

... Quadrature (Counter) Options: Relays (5Amp) Programmable Analog Output RS-485 Communication RS-422 Communication Excitation Other, included: Min/Max, Peak Display Hold User Scaling Screw Terminal Connections Pin mate connector w/6” lead wire Mini-Max Falcon Hawk 3 Temperature Limited Limited C Gima Counters 9 Frequency ...

Page 68

...

Related keywords