Y92F-75 Omron, Y92F-75 Datasheet

ADAPTER FOR H7E

Y92F-75

Manufacturer Part Number
Y92F-75
Description
ADAPTER FOR H7E
Manufacturer
Omron
Type
Panel adapterr
Datasheets

Specifications of Y92F-75

Rohs Compliant
YES
Accessory Type
Adapter - Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H7 Series
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92F75
Z998
Subminiature Total Counters With
Improved Appearance and Features
H
H
H
H
H
H
H
H
H
Ordering Information
J ACCESSORIES (ORDER SEPARATELY)
1. Count Input
3. Case Color
Count input
Count input
PNP/NPN universal DC
voltage input
AC/DC multi-voltage input
No-voltage
Item
Replacement Battery
Wire-wrap Terminal (set of two Terminals)
Flush Mounting Adapter
Self -P owered Count Totalizer
TOTAL COUNTERS
MODEL NUMBER LEGEND
Large display with 8.6 mm (0.338 in) height
Available with backlit LCD
PNP/NPN DC voltage input available
Eight-digits, counting range 0 to 99999999
Key-protect switch to prevent front resetting
Selectable input speed: 30 Hz or 1 kHz
(except for AC/DC multi-voltage input
models)
NEMA 4/IP66 front
Replaceable battery
New black case
g
None: No-voltage input
V:
FV:
B:
p
PNP/NPN universal DC voltage input
AC/DC multi-voltage input
Black
g
p
Max counting speed
Max. counting speed
30 Hz or 1 kHz (Selectable)
20 Hz
30 Hz or 1 kHz (Selectable)
R
26 mm × 45 mm
24.8 mm × 48.8 mm
1
Display
Display
7-segment LCD with
backlight
7-segment LCD
7-segment LCD
7-segment LCD
2. Display
None: 7-segment LCD without backlight
H:
7-segment LCD with backlight
Part number
Y92S-36
Y92S-37
Y92F-75
Y92F-77B
Part number
Part number
H7EC-NV-BH
H7EC-NV-B
H7EC-NFV-B
H7EC-N-B
H7EC

Related parts for Y92F-75

Y92F-75 Summary of contents

Page 1

... Display Display 7-segment LCD with backlight 7-segment LCD 7-segment LCD 7-segment LCD 2. Display None: 7-segment LCD without backlight H: 7-segment LCD with backlight 26 mm × 24.8 mm × 48 H7EC Part number Part number H7EC-NV-BH H7EC-NV-B H7EC-NFV-B H7EC-N-B Part number Y92S-36 Y92S-37 Y92F-75 Y92F-77B ...

Page 2

H7EC Specifications GENERAL Item H7EC-NV-B H7EC-NV-BH Operating mode Up type Mounting method Flush mounting External connections Screw terminals, optional Wire-wrap Terminals (See Note 1.) Reset External/Manual reset Number of digits 8 Count input PNP/NPN universal DC voltage input Display 7-segment ...

Page 3

H7EC J CHARACTERISTICS Item H7EC-NV-B H7EC-NV-BH Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current carrying metal parts, and between the backlight power supply terminal and count input terminals/reset terminals for backlight models Dielectric ...

Page 4

H7EC Nomenclature J TOTAL COUNTER Counting speed switch For all models except for H7EC-NFV-j If the switch setting is changed, press the Reset Key on the front panel. Setting Counting speed (see note) Front panel 30 Hz (default setting) 1 ...

Page 5

H7EC Dimensions Unit: mm (inch) J H7EC-N 24 (0.94) Dimensions with Flush Mounting Bracket 35 (1.38) Installation J TERMINAL ARRANGEMENT Bottom view: View of the Total Counter rotated horizontally 180° Backlight Model Non-backlight Model Backlight 24 VDC Count Reset input ...

Page 6

H7EC Connections J PNP/NPN UNIVERSAL DC VOLTAGE INPUT MODEL WITH BACKLIGHT 1. Contact Input (Input by a Relay or Switch Contact) Relay Backlight 24 VDC Input Reset or Switch or Switch 2. Solid-state Input Relay Open collector of a PNP ...

Page 7

... Contact Input (Input by a Relay or Switch Contact) Relay Note: Use Relays and Switches that have high contact reli- ability because the current flowing from terminals small as approx. 10 µA. OMRON’s G3TA-IA/ID is recommended as the SSR. 2. Solid-state Input (Open Collector Input of an NPN Transistor) Open collector of an ...

Page 8

... Accessories (Order Separately) An H7EC is supplied with a mounting bracket and nut. In addition, the Flush Mounting Adapters shown here allow the H7EC to be fitted to existing panel cutouts. J Y92F-75 FLUSH MOUNTING ADAPTER FOR 26 ¢ 45 RECTANGULAR CUTOUT Must be used with mounting bracket supplied with the Counter 31 24 ...

Page 9

H7EC J Y92S-36 REPLACEMENT (LITHIUM) BATTERY (3 V) 24.5 dia. 7.7 Precautions ! WARNING This product has a built-in lithium battery. Do not short-circuit the + and -- terminals, charge, disassemble, deform, or expose the battery to fire. The battery ...

Page 10

H7EC J RESET INPUT AND COUNT INPUT The H7EC operates using its built-in Battery. If the H7EC is connected to a device that has +V and OUT terminals that are connected with a diode as shown in the circuit diagram, ...

Page 11

... When connecting count input from an SSR to the Counter that operates with AC/DC voltage input, use OMRON’s G3TA-IA or G3TA-ID SSR. Otherwise, make sure that the leakage current of the SSR is 0.1 mA maximum or connect a bleeder resistor in parallel to the input circuit of the Counter ...

Page 12

... One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC TMCN1 3/02 OMRON ON- -LINE Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci Specifications subject to c hange without notice. 12 H7EC OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed i n U.S.A. ...

Related keywords