750126 PILZ, 750126 Datasheet - Page 3

no-image

750126

Manufacturer Part Number
750126
Description
PNOZ S6.1 24VDC
Manufacturer
PILZ
Datasheet

Specifications of 750126

Coil Voltage Vdc Nom
24V
Contact Current Max
8A
Contact Voltage Ac Nom
240V
Contact Voltage Dc Nom
24V
No. Of Poles
3
Relay Mounting
DIN Rail
External Width
22.5mm
External Depth
120mm
Svhc
No SVHC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Two-hand relays
Up to PL e of EN ISO 13849-1
PNOZ s6.1
Function description
Timing diagram
Key
Wiring
Please note:
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
The two-hand control relay must be
activated by simultaneously press-
POWER: Supply voltage
Button 1/Button 2: Input circuits
S13-S14, S23-S24
Feedback loop: Feedback loop S34
Output safe: Safety outputs 13-14,
23-24, 33-34
Information given in the “Technical
details” must be followed.
Outputs 13-14, 23-24, 33-34 are
safety contacts, output 41-42 is an
auxiliary contact (e.g. for display).
To prevent contact welding, a fuse
should be connected before the
output contacts (see technical de-
tails).
Calculation of the max. cable runs
l
R
ance (see technical details)
R
Use copper wire that can withstand
60/75 °C.
Sufficient fuse protection must be
provided on all output contacts with
capacitive and inductive loads.
max
lmax
l
/km = cable resistance/km
in the input circuit:
= max. overall cable resist-
ing two buttons within 0.5 s. If one
or both of the buttons are released,
the unit interrupts the control com-
mand for the hazardous movement.
Output aux: Auxiliary contacts 41-
42
Out semi: Semiconductor output
switch status Y32
t
t
0
1
: Recovery time after power on
: Simultaneity, channel 1 and 2
Shaded area: Status irrelevant
Reactivation: The output relays will
not re-energise until both operator
elements have been released and
then re-operated simultaneously.
t
button 1 or 2
t
before the button is operated (re-
covery time)
2
3
: Operating cycle ended through
: S34-S12 must be closed before
NSG-D-2-405-2008-11
-2