Specifications of Y92A-48

Rohs Compliant
YES
Accessory Type
Cover
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H5CX-A/-L
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With
H7CZ Series Digital Counters
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Y92A48
Operation in Run Mode
Input Modes and Present Value
I/O Functions for Counter Operation
* Counting starts when the count input is turned ON after turning ON the power.
• Set values for each digit as required using the U Key.
• Present Value
• Set Values
Shows the present count value.
Set the set values.
When the present value reaches the set value, a signal
is output according to the specified output mode.
Count input
Present value
H
L
0
0
1
UP (Increment) Mode
2
Present value
Set value
3
4
Note: 1. The meaning of the H and L symbols in the tables is explained
Count input
Present value
below.
Symbol
Input method
H
L
0
H
L
n
n−1
DOWN (Decrement) Mode
n−2
No-voltage input
(NPN input)
Short-circuit
n−3
Open
n−4
H7CZ