AYLD39911DN-G-24V IDEC, AYLD39911DN-G-24V Datasheet - Page 125

no-image

AYLD39911DN-G-24V

Manufacturer Part Number
AYLD39911DN-G-24V
Description
SWITCH, EMERGENCY STOP, 1NO/1NC, 600VAC
Manufacturer
IDEC
Datasheet

Specifications of AYLD39911DN-G-24V

Contact Configuration
SPDT-1NO / 1NC
Switch Operation
Push-Pull
Contact Voltage Ac Nom
600V
Contact Voltage Dc Nom
220V
Contact Current Max
10A
Illumination Color
Green
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
www.idec.com
Panel Mounting
Remove the contact block from the operator. Insert the operator into the panel
cut-out from the front, then install the contact block to the operator.
Removing the Contact Block
Turn the locking lever on the contact block in the direction opposite to the
arrow on the housing. Then the contact block can be removed.
Installing the Contact Block
Insert the contact block, with the TOP markings on the contact block and the
operator placed in the same direction. Then lock the units, turning the locking
lever in the direction of the arrow.
Notes on Mounting
Use the optional Ring Wrench (LW9Z-T1) to mount the operator onto a panel.
Tightening torque should not exceed 1.2N-m (12 kgf-cm). Do not use pliers.
Excessive tightening will damage the locking ring.
Wiring
1. Solder the terminals within 20W/5 seconds or 260°C/3 seconds without
2. Use a non-corrosive resin liquid flux.
Collective Mounting
As the locking lever can be turned easily from the rear of the units using a
screwdriver, the contact blocks can be removed even when
mounted collectively.
Notes for Terminal Cover
(Solder/Tab Terminal)
Insert the terminal cover into the contact block with the TOP markings on the
contact block and the terminal cover in the same direction.
Notes for Wiring
When installing a terminal cover onto the solder/tab terminal contact block,
solder the inside of lamp terminal (toward the switch terminals) and wire.
(Screw Terminal Type)
Install a terminal cover to the control unit before wiring.
exerting external force to the terminals. While soldering, do not touch the
soldering iron to the housing. While wiring, prevent tension from being
applied to the terminals. Do not bend or raise the terminals, nor exert
excessive force
to terminals.
When wiring, insert the lead wires into the terminal cover holes
before wiring.
1. After wiring, terminal covers cannot be installed.
2. When terminal covers are used, round crimping terminals
cannot be used.
Oiltight Switches & Pilot Devices
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Instructions con’t
Connection
Positive-lock connector and easy-lock connector are applicable to
tab terminals.
Single Board Mounting
Mounting the switches and pilot lights on one PC board offers the following
features.
1. Reduced installation labor, easy wiring, space saving, and standardization.
2. Since the contact blocks on the PC board can be removed easily using a
3. Because the LW series switches and pilot lights require no studs for fasten-
For details on one board mounting, contact IDEC.
locking lever, the LW series switches and pilot lights are easy to maintain.
ing the control unit to a PC board, special preparation of operation panel is
not needed.
Light Touch And High Reliability
Operating-force Snap Switching Mechanism
Load (g)
2000
1500
1000
500
Stroke
0
0.039"
(1mm)
0.117"
(3mm)
0.078"
(2mm)
LW series pushbutton
(Momentary DPDT)
0.117"
Stroke
(3mm)
0.156"
(4mm)
LW series pushbutton
(Momentary SPDT)
0.195"
(5mm)
ø22mm - LW Series
0.234"
(6mm)
TW series pushbutton
(SPST-NO/SPST-NC)
A3-125
A3