Specifications of AYLD39911DN-G-24V

Contact Configuration
SPDT-1NO / 1NC
Switch Operation
Push-Pull
Contact Voltage Ac Nom
600V
Contact Voltage Dc Nom
220V
Contact Current Max
10A
Illumination Color
Green
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
A3
ø22mm - LW Series
A3-124
Replacement of Lens & Marking Plate
Removing
1. Remove the operator (lens, marking plate, and lens holder) by inserting a
screwdriver into the recess of the lens through the bezel.
2. Remove the marking plate by pushing the lens from the rear to disengage
the latches between the lens and the lens holder, using the screwdriver as
shown below.
Installing
For round lens types, place the marking plate on the lens holder with the anti-
rotation projection engaged and press the lens onto the lens holder to engage
the latches. For square lens types, insert the marking plate into the lens, and
press the lens onto the lens holder to engage the latches.
Pay attention to the orientation of the marking plate.
Replacement of Lamps
Lamps can be replaced using the lamp holder tool (OR-55) from the front of
the panel. Also by removing the contact block from the operator unit, the lamp
can be replaced.
Replacement of Lamps from the Front of the Panel.
(How to Remove)
1. Push and turn the lamp counterclockwise using the side A of the
lamp holder tool, and the lamp and the lamp holder can be removed.
(How to Install)
1. Insert the lamp into the lamp holder tool and hold the lamp as in the
following illustration.
2. Place the insertion guide of the lamp and the groove in the operator unit in
The translucent filter in the lens holder can
not be removed because this filter is sealed to
make the unit waterproof and oiltight.
Pay attention to the orientation of the
marking plate.
For Round Lens
Lens Marking Plate Lens Holder
Lamp
www.idec.com
Lamp Holder Tool
For Square Lens
Lens Marking Plate Lens Holder
Oiltight Switches & Pilot Devices
Instructions — LW Series
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
the same direction. Then push the lamp lightly and turn it clockwise.
Replacement of Lamps by Removing the Contact Block
The lamp can be replaced by removing the contact block without using the
lamp holder tool.
Marking Plates & Films
For LW series illuminated pushbuttons and pilot lights, legends and symbols
can be engraved on marking plates, or printed mylar can be inserted under the
lens for labelling purposes.
Marking Plate and Marking Film Size
Insertion Order of Marking Plate & Film
Insertion Order of Marking Plate & Film.
Lens Style
Built-in
Marking
Plate
Applicable
Marking
Film
For Round Lens
For Square Lens
Lens
Lens
1. Mylar is not included.
2. Pay attention to the orientation of marking plate.
Film
Film
Marking Plate
Marking Plate
Round Lens
Engraving must be made on the engraving area within
0.02"
The marking plate is made of white acrylic resin.
Mylar for printing labels are not included and must be
provided and printed by user.
Two 0.004"
film can be installed in the lens.
Recommended marking film: Mylar
(0.85mm)
0.033"
(0.5mm)
ø0.694"
0.69"
Lens Holder
Lens Holder
(0.1mm)
Engraving
deep.
(17.7mm)
Area
(ø17.8mm)
-thick films or one 0.008"
Grooves in the
Operator Unit
Housing
Housing
Square Lens
(0.85mm)
0.033"
Top Marking Side
Top Marking Side
ø0.683"
(0.2mm
Engraving
Area
(ø17.5mm)
)-thick