APDS-9002-021 Avago Technologies US Inc., APDS-9002-021 Datasheet - Page 9

AMBIENT LIGHT SENSOR 4CHIPLED

APDS-9002-021

Manufacturer Part Number
APDS-9002-021
Description
AMBIENT LIGHT SENSOR 4CHIPLED
Manufacturer
Avago Technologies US Inc.
Type
Ambient Light Photo Sensor with Phototransistor Outputr
Datasheet

Specifications of APDS-9002-021

Lens Type
Transparent
Maximum Dark Current
160 nA
Maximum Rise Time
2 ms
Maximum Fall Time
2 ms
Package / Case
Chip LED-4
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Product
Ambient Light Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1714-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APDS-9002-021
Manufacturer:
FSC
Quantity:
1 100
9
Recommended Reflow Profile
Process Zone
Heat Up
Solder Paste Dry
Solder Reflow
Cool Down
The reflow profile is a straight-
line representation of a nominal
temperature profile for a
convective reflow solder process.
The temperature profile is divided
into four process zones, each with
different DT/Dtime temperature
change rates. The DT/Dtime rates
are detailed in the above table.
The temperatures are measured
at the component to printed
circuit board connections.
In process zone P1, the PC board
and APDS-9002 castellation pins
are heated to a temperature of
160 C to activate the flux in the
solder paste. The temperature
ramp up rate, R1, is limited to 4 C
per second to allow for even
heating of both the PC board and
APDS-9002 castellations.
255
230
220
200
180
160
120
80
25
0
HEAT
R1
UP
P1
Symbol
P1, R1
P2, R2
P3, R3
P3, R4
P4, R5
50
SOLDER PASTE DRY
R2
P2
100
t-TIME (SECONDS)
Process zone P2 should be of
sufficient time duration (60 to 120
seconds) to dry the solder paste.
The temperature is raised to a
level just below the liquidus point
of the solder, usually 200 C
(392 F).
Process zone P3 is the solder
reflow zone. In zone P3, the
temperature is quickly raised
above the liquidus point of solder
to 255 C (491 F) for optimum
results. The dwell time above the
liquidus point of solder should be
between 20 and 60 seconds. It
usually takes about 20 seconds to
assure proper coalescing of the
solder balls into liquid solder and
the formation of good solder
connections. Beyond a dwell time
of 60 seconds, the intermetallic
DT
25 C to 160 C
160 C to 200 C
200 C to 255 C (260 C at 10 seconds max.)
255 C to 200 C
200 C to 25 C
150
R3
MAX. 260 C
REFLOW
SOLDER
60 sec.
ABOVE
220 C
MAX.
P3
200
R4
DOWN
COOL
P4
R5
250
300
growth within the solder
connections becomes excessive,
resulting in the formation of weak
and unreliable connections. The
temperature is then rapidly
reduced to a point below the
solidus temperature of the solder,
usually 200 C (392 F), to allow
the solder within the connections
to freeze solid.
Process zone P4 is the cool down
after solder freeze. The cool down
rate, R5, from the liquidus point
of the solder to 25 C (77 F)
should not exceed 6 C per second
maximum. This limitation is
necessary to allow the PC board
and APDS-9002 castellations to
change dimensions evenly,
putting minimal stresses on the
APDS-9002.
Maximum DT/DTime
4 C/s
0.5 C/s
4 C/s
-6 C/s
-6 C/s

Related parts for APDS-9002-021