TLE4942-1 Infineon Technologies, TLE4942-1 Datasheet - Page 17

no-image

TLE4942-1

Manufacturer Part Number
TLE4942-1
Description
IC HALL EFFECT SENSOR SSO-2
Manufacturer
Infineon Technologies
Type
Special Purposer
Datasheet

Specifications of TLE4942-1

Sensing Range
40% ~ 60%
Voltage - Supply
4.5 V ~ 20 V
Current - Supply
8.4mA
Output Type
PWM (Current)
Features
High Sensitivity
Operating Temperature
-40°C ~ 150°C
Package / Case
2-SIP, SSO-2-2
Operating Supply Voltage
5 V or 9 V or 12 V
Mounting Style
Through Hole
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output (max)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SP000015067

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE4942-1C
Manufacturer:
INFINEON
Quantity:
10 000
Part Number:
TLE4942-1C
0
TLE4942-1
TLE4942-1C
I
Xn
Xn+1
Xn+2
I
HIGH
I
LOW
t
1
T
t
t
Duty =
/ T x 100%
1
AET03195
Figure 7
Definition of Duty Cycle
PWM Current Interface
Between each magnetic transition and the rising edge of the corresponding output pulse
t
the output current is Low for
in order to allow reliable internal conveyance.
pre-low
Following the signal pulse (current is High) is output.
If the magnetic differential field exceeds ∆
B
, the output pulse lengths are 90 µs or
EL
180 µs respectively, depending on the direction of rotation.
When the magnitude of the magnetic differential field is below ∆
B
, the output pulse
EL
lengths are 360 µs and 720 µs respectively, depending on left or right rotation. Due to
decreasing cycle times at higher frequencies, these longer pulses are only output up to
frequencies of approximately 117 Hz. For higher frequencies and differential magnetic
fields below ∆
B
, the output pulse lengths are 90 µs or 180 µs respectively.
EL
If the magnitude of the magnetic differential field is below ∆
B
, the output pulse
Warning
length is 45 µs. The warning output is dominant, this means that close to the limit airgap
the direction and the assembly position information are disabled.
For magnitudes of the magnetic differential field below ∆
B
, signal is lost.
Limit
In case no magnetic differential signal is detected for a time longer than the stand still
T
period
, the stop pulse is output. Typically with the first output stop pulse, the circuitry
Stop
reverts to the uncalibrated mode.
Data Sheet
17
V 3. 1, 2005-02

Related parts for TLE4942-1