LY530ALH STMicroelectronics, LY530ALH Datasheet - Page 7

GYRO 300DEG/S 3.3MV 1.4KHZ

LY530ALH

Manufacturer Part Number
LY530ALH
Description
GYRO 300DEG/S 3.3MV 1.4KHZ
Manufacturer
STMicroelectronics
Datasheet

Specifications of LY530ALH

Featured Product
STM32 Cortex-M3 Companion Products
Range °/s
±300°/s
Sensitivity
3.3mV/°/S
Typical Bandwidth
140Hz
Voltage - Supply
2.7 V ~ 3.6 V
Current - Supply
6.8mA
Output Type
Analog
Operating Temperature
-40°C ~ 85°C
Package / Case
16-LGA
Sensing Axis
Single
Supply Current
5 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.7 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8938

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LY530ALHTR
Manufacturer:
LEVELONE
Quantity:
239
LY530ALH
3
3.1
3.2
3.3
3.4
Terminology
Sensitivity
An angular rate gyroscope is a device that produces a positive-going output voltage for
counterclockwise rotation around the sensitive axis considered. Sensitivity describes the
gain of the sensor and can be determined by applying a defined angular velocity to it. This
value changes very little over temperature and time.
Zero-rate level
Zero-rate level describes the actual output signal if there is no angular rate present. The
zero-rate level of precise MEMS sensors is, to some extent, a result of stress to the sensor
and therefore zero-rate level can slightly change after mounting the sensor onto a printed
circuit board or after exposing it to extensive mechanical stress. This value changes very
little over temperature and time.
Self-test
Self-test allows testing of the mechanical and electrical part of the sensor, allowing the
seismic mass to be moved by means of an electrostatic test-force. The self-test function is
off when the ST pin is connected to GND. When the ST pin is tied to Vdd, an actuation force
is applied to the sensor, emulating a definite Coriolis force. In this case the sensor output will
exhibit a voltage change in its DC level which is also dependent on the supply voltage.
When ST is active, the device output level is given by the algebraic sum of the signals
produced by the velocity acting on the sensor and by the electrostatic test-force. If the output
signals change within the amplitude specified in
working properly and the parameters of the interface chip are within the defined
specifications.
High pass filter reset (HP)
The LY530ALH provides the possibility to reset the optional external high pass filter by
applying a high logic value to the HP pad. This procedure ensures faster response,
especially during overload conditions. Moreover, this operation is suggested each time the
device is powered.
Doc ID 15801 Rev 2
Table
3, then the mechanical element is
Terminology
7/12

Related parts for LY530ALH