PF2D520-13-1 SMC Corporation of America, PF2D520-13-1 Datasheet

no-image

PF2D520-13-1

Manufacturer Part Number
PF2D520-13-1
Description
SENSOR FLOW CHEM 1.8-20L/MIN
Manufacturer
SMC Corporation of America
Series
PF2Dr
Datasheet

Specifications of PF2D520-13-1

Sensing Range
1.8 ~ 20 LPM
Flow Sensor Type
Liquid
Voltage - Input
12 ~ 24 V
Port Size
Female, 1/2", 0.5" (12.7mm) NPT
Material - Body
Steel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Switch Function/rating
-
Other names
606-1040
Digital Flow Switch for Air: Series PF2A ························································· Refer to page 16-11-7.
Digital Flow Switch for Water: Series PF2W ··················································· Refer to page 16-11-17.
Digital Flow Switch for Deionized Water and Chemicals: Series PF2D ······ Refer to page 16-11-37.
Diaphragm Style Flow Switch: Series IFW
Paddle Style Flow Switch: Series IF3
IFW510
IFW520
IFW550
1F3„0
1F3„1
1F3„3
Model
Model
Flow rate measuring range
Flow rate measuring range
Series
Flow Switches
36 to 2600
20 to 150
10 to 20
20 to 50
14 to 60
1 to 10
(l /min)
(l /min)
Mechanical Flow Switch
Digital Flow Switch
PF2 „ , IF „
Contacts
Contacts
1ab
1ab
Port size (Rc, NPT, G)
Port size (Rc, NPT, G)
3/8, 1/2, 3/4
3/4
1
1
16-12-1
16-12-6
Page
Page
16-11-1
ZSE„
ISE„
PSE
Z
PS
Z
ZSP
ISA2
IS„
ZSM
PF2„
IF„
Data
I
I
SE3
SE
1
2

Related parts for PF2D520-13-1

PF2D520-13-1 Summary of contents

Page 1

... Digital Flow Switch for Water: Series PF2W ··················································· Refer to page 16-11-17. Digital Flow Switch for Deionized Water and Chemicals: Series PF2D ······ Refer to page 16-11-37. ...

Page 2

... Never use flammable gases or fluids, since the switch is not explosion proof construction. It may result in a fire. [For air] 4. Make sure to use a switch within the specified flow rate for measurement and the maximum operating pressure. Operating beyond the specified flow rate and operating pressure can damage the switch ...

Page 3

... Do not disassemble or modify the main body. Warning 1. Check regulators and the flow adjustment valves before introducing the fluid. If pressure or flow rate beyond the specified range are applied to the switch, the sensor unit may be damaged. [For air] 2. Fluids for measurement for this digital flow switch are nitrogen and air ...

Page 4

... Integrated and remote type displays Three types of output: 3 Switch, accumulated pulse, and analog outputs. Switching from real-time flow rate to 4 accumulated flow is possible. 5 Two independent flow rate settings are possible. 6 Water resistant construction conforming to IP65 Flow rate measurement l range ( /min) For Air ...

Page 5

... Output from integrated display type and remote display unit type : Output from remote sensor unit type Flow rate Remote type measurement l Switch output Analog output Display unit Sensor unit range /min PF2W504T 0 „ PF2W30 ...

Page 6

... Note 1) For digital flow switch with unit switching function. (Fixed SI unit [(l/min function.) Note 2) Flow rate display can be switched between the basic condition of 0°C, 101.3 kPa and the standard condition (ANR) of 20°C, 101.3 kPa, and 65% RH. Note 3) Without lead wire. ...

Page 7

... RESET Buttons Press the and buttons simultaneously to activate the RESET function. This clears the unit when an abnormality occurs and resets the accumulated flow display to “0”. Output (OUT1) Indicator: Green Lights up when OUT1 is ON. Blinks when an overcurrent error occurs on OUT1. OUT1 Output (OUT2) Indicator: Red Lights up when OUT2 is ON ...

Page 8

... Flow direction PF2A711/721/751 116 88 FLOW SWITCH U P SET OUT1 OUT2 DOWN FOR AIR 4–ø4 Flow direction Digital Flow Switch 2-Port size 24 (41. 2-Port size 30 (41.5) PF2A Series For Air Internal circuit and wiring example to are terminal numbers. 6 1.6 ...

Page 9

... ON OFF Output mode 50 msec ON Note 1) OFF “n” Note 1) For digital flow switch with unit switching function. (Fixed SI unit [l/min for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse. ZSE„ ...

Page 10

... Data of the flow switch will be stored even after the power is turned off. Input data will be stored in EEPROM so that the data will not be lost after the flow switch is turned off. (Data can be rewritten for up to one million times, and data will be stored for years.) Warning 1 ...

Page 11

... Avoid sources of surge generation and crossed lines. 4. Switches are not equipped with surge protection against lightning. Flow switches are CE compliant; however, they are not equipped with surge protection against lightning. Lightning surge protection measures should be applied directly to flow system components as necessary ...

Page 12

... The volumetric flow rate at 20°C, 101.3 kPa, and 65% RH (ANR) can be displayed with the high flow rate type switches for air. Detection principle of digital flow switch for water When an elongated object (vortex generator) is placed in the flow, reciprocal vortexes are generated on the downstream side ...

Page 13

... The rated flow rate range is the range of flow rate that satisfies the specifications (accuracy, linearity, etc.) of the sensor. Although it is possible to set a value outside the rated flow rate range, the specifications will not be guaranteed even if the value stays within the regulating flow rate range. ...

Related keywords