1.20122.062/0000 C&K Components, 1.20122.062/0000 Datasheet - Page 52

CONTACT BLOCK, 2NO, 6A, QUICK CONNECT

1.20122.062/0000

Manufacturer Part Number
1.20122.062/0000
Description
CONTACT BLOCK, 2NO, 6A, QUICK CONNECT
Manufacturer
C&K Components
Datasheet

Specifications of 1.20122.062/0000

No. Of Poles
2
Contact Current Max
6A
Contact Voltage Ac Max
250V
Contact Voltage Dc Max
250V
For Use With
C&K Rafix 16 Series Non-illuminated Square Pushbutton Switches With Flush Lens
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2
RAFIX
16
RAFIX 16
The AS-Interface E-stop contact block is a slave for the AS-I fieldbus system. It is designed for the standard address
range and meets the AS-I profile S-7.B.E (safety slave with max. 4 input / 4 output lines). Up to 30 of these contact blocks
can be linked to one AS-I line, the 31
fer of the E-stops switching position signal. The (not safe) output line is used to control the lamp in the E-stop or for an
external signal lamp (option).
The coupling contact is an additional safety feature. It supervises the coupling between E-stop actuator and contact block
and informs the AS-I bus, when this connection is interrupted.
Dimensions
Length
Width
Height
Mounting depth
Key grid
Mechanical design
Mounting
Contact system
Contact materials
Contact arrangement
Illumination
Mounting position
Terminals
Coupling contact
2-pole digital output,
24 V / 15 mA
Robustness
Electrical characteristics
Rated voltage AC / DC
Rated current AC / DC
Other specifications
Operating life
Approvals / CE
Operating temperature
min.:
Operating temperature
max.:
Storage temperature min.:
Storage temperature max.:
2 - 52
General data
Technical data
RAFIX 16 contact blocks AS-Interface, E-stop, Safety at Work
53.7 mm
48.0 mm
53.7 mm
56 mm
50 x 30 mm
snap on actuator
bridge-contact self
cleaning
Au
2NC
1 x LED red
variable
supplied connector
see order block
see order block
100 N
24 V
0.01 ... 50 mA
1 Mio. operations at 24
V/50 mA DC
according to 89/336/EWG
-25 °C
70 °C
-40 °C
80 °C
st
. member is a safety monitor. The four (safe) input lines are used for the safe trans-
Resistance to constant
environment:
Vibration resistance:
Shock resistance acc. to
IEC 60068-2-27
AS-I Schnittstelle
AS-Interface profile
Terminal code
Rated voltage
Rated current
Deceleration time for
readiness
AS-Interface IC
AS-Interface
specification
AS-Interface certificate
Probability of failure,
acc. to IEC 61508
IEC 60068-2-78
10 g at 40 ... 500 Hz
50 g at 11 ms amplitude,
half sinusoidal
S-7.B.E
yes
26.5 ... 31.6 V
60 mA
(Version 002: 50 mA)
1 sec
A
V3.0
ZU 63001, 63701
PFD total: 2.2 x 10
operation period: 10 years
PFH/h: 2.5 x 10
2
SI
Control components
-9
-4
,

Related parts for 1.20122.062/0000